User manual AEG-ELECTROLUX RM6401LDH

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX RM6401LDH. We hope that this AEG-ELECTROLUX RM6401LDH user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX RM6401LDH.


Mode d'emploi AEG-ELECTROLUX RM6401LDH
Download
Manual abstract: user guide AEG-ELECTROLUX RM6401LDH

Detailed instructions for use are in the User's Guide.

[. . . ] MANUAL ABSORPTION REFRIGERATOR for RECREATIONAL VEHICLES RM 6290 LD(H) RM 6291 LD(H) RM 6400 LD(H) RM 6401 LD(H) EN English OPERATING INSTRUCTIONS INSTALLATION INSTRUCTIONS T. B. 10/2003 Typ C40 / 110 INTERNET www. dometic. com Kundeservice Kundendienst Customer Service Servicio de Atencin al Cliente Service aprs-vente Servizio Clienti Klantenservice Kundeservice Servio de Atendimento a Clientes Asiakaspalvelu Kundservice These operating instructions should be kept in a safe place. If this device is passed on, please include these operating instructions with it. Dometic GmbH - 2002 - Subject to change without notice - Printed in Germany 2 1. 0 2. 0 INTRODUCTION FOR YOUR SAFETY 2. 1 2. 2 Coolant TABLE OF CONTENTS Warning and safety notices 4 4 4 5 4 3. 0 4. 0 5. 0 WARRANTY AND CUSTOMER SERVICE 3. 1 Damage in transit 5 DESCRIPTION OF MODEL REFRIGERATOR GUIDE 5. 1 5. 2 5. 3 5. 4 5. 5 5. 6 5. 7 5. 8 5. 9I 5. 10 5. 11 5. 12 5. 13 5. 14 5. 15 5. 16 5. 17 5. 18 Cleaning Switching on the refrigerator Switching off the refrigerator Defrosting Storing food Making ice cubes Door locking Winter operation nterior light Changing the decor panel Positioning the storage racks Troubleshooting Maintenance Environmental hints Disposal Energy-saving tips Technical data Declaration of conformity 5 6 8 9 9 9 9 10 10 11 11 12 12 13 13 13 13 14 5 5 6. 0 INSTALLATION GUIDE 6. 1 6. 2 6. 3 6. 4 6. 5 6. 6 6. 7 6. 8 6. 9 Installation Draught-free installation Ventilation and air extraction Installation of the ventilation system Installation recess Securing the refrigerator Fume extraction Gas installation Electrical installation 15 16 17 18 15 19 19 20 21 23 3 1. 0 INTRODUCTION You have made an excellent choice in selecting the Dometic Absorption Refrigerator. We are sure that you will be fully satisfied with your new appliance in all respects. [. . . ] For eco-friendly draining of the coolant from all absorber refrigeration units, a suitable disposal plant should be used 5. 16 Energy-saving tips At an average ambient temperature of approx. 25C, it is sufficient to operate the refrigerator at the middle thermostat setting (for both gas and mains voltage). Where possible, always store goods that have previously been cooled. Do not position the refrigerator in direct sunlight. Constant circulation of air must be supplied to the refrigerator unit. Open the door only for a short time when removing goods from the refrigerator. Run the refrigerator for about 12 hours before filling it. 5. 17 Technical data Model Dimensions H x W x D (mm) depth incl. door 821x525x607 821x525x607 821x525x607 821x525x607 826x525x607 826x525x607 826x525x607 826x525x607 Groos capacity Usable Connection incl. freezer capacity of Mains / Battery compartment freezer compartment 97 lit. 125W / 120W 125W / 120W 135W / 130W 135W / 130W 125W / 120W 125W / 120W 135W / 130W 135W / 130W * Consumption electricity / gas in 24 hrs ca. 2, 5KWh / 270g ca. 2, 5KWh / 270g ca. 2, 6KWh / 270g ca. 2, 6KWh / 270g ca. 2, 5KWh / 270g ca. 2, 5KWh / 270g ca. 2, 6KWh / 270g ca. 2, 6KWh / 270g Netweight Ignition Ignition Piezo Reigniter Steppedcabinet RM 6290 LD RM 6291 LD RM 6400 LD RM 6401 LD RM 6290 LDH RM 6291 LDH RM 6400 LDH RM 6401 LDH 28 kg 28 kg 30 kg 30 kg 28 kg 28 kg 30 kg 30 kg X X X X X X X X X X X X We reserve the right to make technical changes. *Average consumption measured at an average ambient temperature of 25C in pursuance of ISO Standard. 13 5. 18 Declaration 14 6. 0 INSTALLATION GUIDE On installation of the appliance, the technical and administrative regulations of the country in which the vehicle will first be used must be adhered to. Otherwise the refrigerator must be installed as described in these instructions. In some OEM applications it may not be possible for these instructions to be followed exactly. In this case an authorised Dometic representative may issue supplementary instruction In Europe, for example, gas appliances, cable laying, installation of gas cylinders, as well as approval and checking for leaks must comply with EN 1949 for liquid gas units in vehicles. 6. 1 Installation The appliance and its fume extraction shall be installed in such a way as to be accessible for servicing at all times and must be capable of easy removal and installation. The appliance may only be installed by authorised personnel. Installation and connection of the appliance must comply with the latest technical regulations, as follows: European Standard EN 1949 European Standard EN 732 The electrical installation must comply with national regulations ( EN 1648-1 , EN 1648-2 , EN 60335-2-24 for Europe). The gas installation must comply with national regulations. Local and building control department requirements The appliance shall be installed in such a way that it is shielded from excessive heat radiation. Excessive heat impairs performance and raises the energy consumption of the refrigerator. Any installation that is not carried out by qualified persons will jeopardize the manufacturer's guarantee. 6. 1. 1 Side Installation If the appliance is installed on the same side of the vehicle as the entrance door, it is desirable that the door does not cover the refrigerators vents. If this cannot be avoided there must be a gap of at least 25mm between the door and the vents. 6. 1. 2 Rear installation If the refrigerator is mounted at the rear of the vehicle you must ensure the lower grille is not covered by the bumper or rear lights. This would be prevent the air from circulating properly and cause problems in warm weather. Air vent grille not blocked: OK! [. . . ] A certificate of testing must be issued. * qualified personnel Qualified personnel are accredited experts who are able, by virtue of their training and knowledge, to vouch for the correct implementation of the leakage test. The refrigerator must be equipped with a gas cock (C) in the supply line to allow the supply to be disconnected. Such a cutout device must be readily accessible to the user. C Gas-pressure Category mbar BE DK DE FI FR GR IE IS IT LU NL NO AT PT SE CH ES UK X X X X X X X X X X X X X X X X X X X X X X X X I3P(30) 30 I 3P(37) 37 I3P(50) 50 28-37 X I3+ 30-37 I3B/P(50) 50 I3B/P(30) 30 X X X 22 6. 9 Electrical installation Electrical installation may only be carried out by qualified personnel. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX RM6401LDH

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX RM6401LDH will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag