User manual AEG-ELECTROLUX S98820-4ILIW

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX S98820-4ILIW. We hope that this AEG-ELECTROLUX S98820-4ILIW user guide will be useful to you.

Lastmanuals help download the user guide AEG-ELECTROLUX S98820-4ILIW.


Mode d'emploi AEG-ELECTROLUX S98820-4ILIW
Download
Manual abstract: user guide AEG-ELECTROLUX S98820-4ILIW

Detailed instructions for use are in the User's Guide.

[. . . ] Never pull the plug out of the socket by the cable or with wet hands. Always take hold of the plug itself and pull it straight out of the socket. This appliance is CFC- and FC-free and contains small quantities of Isobutane (R600a), an environmentally friendly coolant. You must ensure that the cooling circuit is undamaged when handling this appliance. [. . . ] Warmed air must be conducted via the ventilation shaft to the rear wall of the housing and then expelled upwards. The ventilation channels should measure at least 200 cm2 in cross-section. min. To ensure the proper functioning of the appliance, air vents should never be blocked or covered. Installation Scale drawing 200 cm 2 547 550 min. 566 50 874­880 560 min. 873 200 cm 2 6 After installing the unit, and particularly if the door hinge is reversed, please ensure that the door seal is tight all round. An imperfect door seal can lead to increased condensation and thus to higher energy consumption (see the section headed "Troubleshooting"). Electrical connection A properly installed socket outlet with earthing contact is required for electrical connection, positioned so that it is possible to pull out the mains plug. The socket outlet with earthing contact used to connect the appliance should be positioned on the left or right-hand side adjacent to the housing. Electrical fuse protection of at least 10/16 amperes must be provided. If the socke is no longer accessible once the appliance has been built-in, suitable measures must be taken during electrical installation to ensure that the appliance can be disconnected from the mains (fuse, LP [line protection] contact opening width of at least 3 mm). Before operating the appliance, check the nameplate to ensure compliance of the connection voltage and type of current with the mains network values at the installation site. 220 to 240 volt alternating current, 50 Hertz) The nameplate is located inside the appliance on the top right-hand side. 7 Product description 1 2 3 2 1 2 3 Control panel Storage racks (adjustable) Temperature zone divider (adjustable) Control panel 14 2 3 2a 1 2 Appliance on/off Press for at least 3 seconds. Select upper zone temperature (5 to 18° C, adjustable) Recommendation: 5­12° C (ideal for white wine, see page 11) Press for at least 3 seconds indicator flashes The temperature can be adjusted in steps. 2a Select lower zone temperature (5 to 18°C, adjustable) Recommendation: 12­18° C (ideal for red wine, see page 11) The temperature set for the lower zone must always be the same as or higher than that in the upper zone. 8 3 Supercool Press for 3 seconds the yellow pilot light illuminates. The appliance cools the upper zone for 24 hours at +5° C and then automatically at the set temperature. Interior light switched on permanently: Press for 3 seconds ON Interior light on only while the door is open: Press for 3 seconds OFF 4 If the door is kept open for longer than 5 minutes, an acoustic door alarm will sound. This can be switched off by briefly pressing any button. To adjust storage racks The height of the storage racks is adjustable. Pull the shelf forwards, lift on the door side and remove. Reverse this procedure to replace the shelf at a different level. 9 To adjust the temperature zone divider The temperature zone divider can be raised or lowered by 1 position. Pull forwards away from the rear wall, and lift on door side. Reverse this procedure to replace at a different level. Please ensure that the rear section of the temperature zone divider slots into the groove provided in the rear wall. [. . . ] Faults with the mains supply must be repaired by a qualified electrician. Please see under "Commissioning". Only open door for as long as necessary. Inadequate cooling chamber temperature. Temperature has not been properly set. Where coolers are installed in open-plan kitchens or in partition walls, the level of operating noise will be heard more acutely. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX S98820-4ILIW

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AEG-ELECTROLUX S98820-4ILIW will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag