If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AEG-ELECTROLUX Z3820. We hope that this AEG-ELECTROLUX Z3820 user guide will be useful to you.
Lastmanuals help download the user guide AEG-ELECTROLUX Z3820.
Detailed instructions for use are in the User's Guide.
[. . . ] Yes Fan motor is defective No Indoor PCB is defective No Repair the connector
Failure phenomenon Indoor room temp. or evaporator sensor is open circuit or short circuit
Operation lamp
Timer lamp On
Is connection to connector good?Yes Replace the sensor No Repair connector Page 14 of 33
Failure phenomenon Over current protection of the compressor occurs 4 times
Operation lamp X
Timer lamp
Operation lamp off and Timer lamp flashes
After changing the main control board, check if the failure releases.
No
The voltage of power supply is too low (less than 187V)?
Yes
Yes
Indoor PCB is defective
Yes
Power supply fault
No
Outdoor unit fault (such as the compressor)
Failure phenomenon EEROM error
Operation lamp On
Timer lamp
EEROM error, indoor PCB is defective.
Failure phenomenon No over-zero signal Operation lamp Timer lamp
This is alarm signal when the main chip can't detect over-zero signal. When such failure occurs, the main control board must have fault.
7. 2 Outdoor unit
Failure phenomenon Stand by High temp. [. . . ] sensor in condenser 2 is open circuit or short circuit is open circuit or short circuit LED1 LED2 LED3
Flash at 2Hz
Page 15 of 33
8 Electronic functions 8. 1 Electric Control working environment 8. 1. 1 Input voltage: 145~260V 8. 1. 2 Input power frequency: 50Hz/60Hz 8. 1. 3 Ambient temperature: -7°C~+43°C 8. 1. 4 Indoor fan normal working amp is less than 1A, 8. 1. 5 Outdoors fan. Normal working amp is less than 1A 8. 1. 6 Four-way valve normal working amp is less than 0. 5A. 8. 1. 7 Swing motor: DC12V.
8. 2
Proper symbols and their meanings TA: Indoor ambient temperature TE: Indoor evaporator temperature TS: Setting temperature through the remote controller TE1: Anti-cold wind, from Fan Off to Breeze temperature TE2: Anti-cold wind, from Breeze to Setting Fan Speed temperature TE3: Anti-cold wind, from Setting Fan Speed to Breeze temperature TE4: Anti-cold wind, from Breeze to Fan Off temperature TE5: Evaporator low temperature protection entering temperature TE6: Evaporator low temperature protection restoring temperature TE7: Evaporator high temperature protection, compressor off temperature TE8: Evaporator high temperature protection, fan off temperature TE9: Evaporator high temperature protection, restoring temperature T3: Outdoor unit pipe sensor T4: Outdoor temperature sensor Systematic functions. High temperature protection of indoor heat exchanger in heating mode. Auto defrosting and heating recovery under heating mode. Anti frozen under cooling mode.
8. 3
Page 16 of 33
8. 5 8. 5. 1 8. 5. 2 8. 5. 3 8. 5. 4 8. 5. 5
Protection The compressor functions protection with a delay of three minutes. Sensor protection at open circuit and breaking disconnection Temperature Fuse break protection Fan Speed is out of control. When Indoor Fan Speed is too high(higher than High Fan+300RPM)or too low(lower than 400RPM), the entire unit stops and LED displays failure information and can't returns to normal operation automatically. Fan-only mode
Fan speed is high/mid/low/ Auto
8. 6 8. 7
Cooling mode
The 4-way valve is closed under cooling mode. Anti-cold wind control function under heating mode
Condition TE Indoor exchanger temp. up TE<TE1 TE1<TE<TE2 TE>TE2 Indoor exchanger temp. down TE> TE3 TE3<TE<TE4 TE<TE4 Off Breeze Setting fan speed Setting fan speed Breeze Off Indoor fan speed
TE: Indoor evaporator temperature TE1: Anti-cold wind, from Fan Off to Breeze temperature TE2: Anti-cold wind, from Breeze to Setting Fan Speed temperature TE3: Anti-cold wind, from Setting Fan Speed to Breeze temperature TE4: Anti-cold wind, from Breeze to Fan Off temperature
Page 18 of 33
8. 9. 5 Auto wind under heating mode
Condition T=Indoor Temp. -Setting Temp. down T<2 T>2 T> 0 T<0 High Mid. High Indoor fan speed
8. 9. 6 Indoor evaporator high-temperature protection under heating mode
Condition Indoor exchanger temp. up TE<TE8 TE8<TE<TE7 TE>TE7 Indoor exchanger temp. down TE>TE9 TE<TE9 Compressor On On Off Off On Outdoor fan On Off Off Off On
TE: Indoor evaporator temperature TE7: Evaporator high temperature protection, compressor off temperature TE8: Evaporator high temperature protection, fan off temperature TE9: Evaporator high temperature protection, restoring temperature 8. 10 Defrosting operation (Available for heating only). 8. 10. 1 Defrosting condition: When T3<0 and compressor runs 40 minutes. Two hours later, the set temperature will maintain as a constant and the air circulation is kept at low speed (Cold air proof function takes precedence over all). [. . . ] Two hours later, the set temperature will maintain as a constant and the air circulation is kept at low speed (Cold air proof function takes precedence over all). 8. 15. 4 Auto: The economic running function operates in accordance with the selected running mode by the auto mode.
Page 20 of 33
8. 16
Outdoor fan motor T4: Outdoor temp.
T4 Cooling mode Heating mode T4>27 T4<25 T4>13 T4<11 Outdoor fan motor High speed Low speed Low speed High speed
Page 21 of 33
9 Exploded view parts 9. 1 INDOOR UNIT
Exploded View Parts for Model: EL-KFR26G/TN2Y-A(B) 220-240V~ 50Hz :Indoor Unit
No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
Part Name Front panel (type B) Front panel (type A) Air cleaner Air cleaner holder Air filter Screw cap Window cover for repairing Panel frame (type A) Panel frame (type B) Display board assy Holder for display board Air out frame assy Horizontal louver Louver holder I Air out frame Louver holder II Vertical louver Louver motor Drain hose Indoor temp sensor
Quantity 1 1 1 1 2 3 1 1 1 1 1 1 1 1 1 1 10 1 1 1
BOM code 2113039184 2113039179 2113010212 2113010217 2113039175 2113039178 2113039183 2113039176 2113039197 2333039081 2113039199 2113039177 2113039027 2113031305 2113039028 2113031306 2113031365 2240020006 2113000001 2243069052
No. 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37
Part Name Evaporator temp sensor Evaporator Bearing holder Chassis Installation plate Back cover for chassis Clamp for connecting pipe Fan motor Cross flow fan, assy Motor cover Holder for remote controller Remote Controller Transformer Cover for E-parts box Wire joint, 5p E-Parts box Main control board Copper nut, TLM-A01 Copper nut, TLM-B02
Quantity 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1
BOM code 2230130056 2153159019 2273010201 2113031343 2123039002 2113010216 2113010204 2240030005 2113010219 2113010203 2113139022 2335509179 2230090029 2113019182 2243019081 2113159004 2135029046 2160032000 2160032001
Page 22 of 33
Exploded View Parts for Model: Unit
EL-KFR36G/TN2Y-A(B)
220-240V~
50Hz :Indoor
No. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE AEG-ELECTROLUX Z3820
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.