User manual AGA TWO AND FOUR OVEN

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AGA TWO AND FOUR OVEN. We hope that this AGA TWO AND FOUR OVEN user guide will be useful to you.

Lastmanuals help download the user guide AGA TWO AND FOUR OVEN.


Mode d'emploi AGA TWO AND FOUR OVEN
Download
Manual abstract: user guide AGA TWO AND FOUR OVEN

Detailed instructions for use are in the User's Guide.

[. . . ] The wall behind the range must be the outside wall for DIRECT VENT RANGEMODELS GC AND GE the venting of flue products. Wall thickness between 150mm (6 in) and 355mm (14 in) can be catered for at the same time as site inspection. Alternatively, special lengths can be offered to order up to a maximum of 610mm (24 in) long. Open Flue - Models GC and GE BASE OR HEARTH It is essential that the base or hearth on which the range stands should be level and strong enough to support the weight of the range. [. . . ] In Canada: CAN/CGA-B149 installation code. Termination should be on a clear expanse of wall, the terminal being preferably not less than 355mm (14in) away from a corner, recess of projection. A hole must be cut through an outside wall as indicated in Fig. 6 with the hole rising from inside to outside face of wall. DO NOT install the terminal:(a) Within 300mm (12in) measured vertically, from the bottom of an openable window, air vent or any other ventilating opening. (b) Within 300mm (12in) above adjacent ground level. (c) Within 600mm (24in) of any surface facing the terminal. (d) Within 355mm (14in) (U. S. ) or 300mm (12in) (Canada) below eaves or balcony. The direct vent terminal must be protected by a terminal protective guard installed over the terminal to prevent unauthorised contact with hot terminal surfaces. All jointing faces providing primary air and flue exhaust paths, must be sealed in an airtight fashion, with particular emphasis on the following locations: (a) Air intake tube joints to be sealed with silicone adhesive provided. (b) Combustion chamber top sealed with a fire-cemented gasket to the outer barrel. (c) Fire cement joints between underside contact faces of hotplates and simmering plate with cement provided. (d) Gasket between flue intake/exhaust manifold. The air inlet/products outlet direct vent, and the terminal of the appliance must not be less than 300mm (12in) to combustible material. The terminal is suitable for walls of 150mm (6in) to 355mm (14in) overall thickness. For special lengths up to 610mm (24in), consult your local Aga Distributor. WALL TILING If the cooker is to stand in a recess or against a wall which is to be tiled, in no circumstances should the tiles overlap the range top plate. NOTE: A GAS CONTROL VALVE MUST BE INSTALLED. GAS SUPPLY - U. S. PIPE THREADS IN THE GAS PIPELINE EXTERNALLY OF THE RANGE (NOT SUPPLIED). Male connection near the front of the range on the L. H. Maximum Heat Input: 4. 4 kw (15, 000 Btu/h) 3 GC, GE Open Flue Models Maximum Heat Input: 4. 4kw (15, 000 (Btu/h) GC, GE Direct Vent Models The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3. 5kPa). The appliance must be isolated from the gas supply piping system by closing the individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3. 5kPa). LOCATION OF NAME PLATE The model and serial numbers for this appliance are found on the name plate. These numbers must be used when requesting advice from your Aga Distributor. [. . . ] Visually check main burner and pilot flame for correct flame pattern. An established main burner at high fire will be predominantly blue with yellow tippings on an even height flame strip and be about 150mm (6in) high. Ensure all flameports have cross-lit and that the pilot light flame is free from sooting. The maximum depth of any cabinets installed above the top cooking surface of the range must not exceed 330mm (13in). YEARLY SERVICE The appliance and its individual shut-off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressure in excess of 1/2 psig (3. 5kPa). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AGA TWO AND FOUR OVEN

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AGA TWO AND FOUR OVEN will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag