User manual AGILENT TECHNOLOGIES 34401A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AGILENT TECHNOLOGIES 34401A. We hope that this AGILENT TECHNOLOGIES 34401A user guide will be useful to you.

Lastmanuals help download the user guide AGILENT TECHNOLOGIES 34401A.


Mode d'emploi AGILENT TECHNOLOGIES 34401A
Download
Manual abstract: user guide AGILENT TECHNOLOGIES 34401A

Detailed instructions for use are in the User's Guide.

[. . . ] Agilent 34401A 6 ½ Digit Multimeter User's Guide Agilent Technologies Notices © Agilent Technologies, Inc. 1991 - 2007 No part of this manual may be reproduced in any form or by any means (including electronic storage and retrieval or translation into a foreign language) without prior agreement and written consent from Agilent Technologies, Inc. as governed by United States and international copyright laws. Warranty The material contained in this document is provided "as is, " and is subject to being changed, without notice, in future editions. Further, to the maximum extent permitted by applicable law, Agilent disclaims all warranties, either express or implied, with regard to this manual and any information contained herein, including but not limited to the implied warranties of merchantability and fitness for a particular purpose. [. . . ] This command does not initiate the measurement. 4 119 Chapter 4 Remote Interface Reference The MEASure?and CONFigure Commands CONFigure:FREQuency {<range>|MIN|MAX|DEF}, {<resolution>|MIN|MAX|DEF} Preset and configure a frequency measurement with the specified range and resolution. This command does not initiate the measurement. For frequency measurements, the multimeter uses one "range" for all inputs between 3 Hz and 300 kHz. With no input signal applied, frequency measurements return "0". CONFigure:PERiod {<range>|MIN|MAX|DEF}, {<resolution>|MIN|MAX|DEF} Preset and configure a period measurement with the specified range and resolution. This command does not initiate the measurement. For period measurements, the multimeter uses one "range" for all inputs between 0. 33 seconds and 3. 3 µsec. With no input signal applied, period measurements return "0". CONFigure:CONTinuity Preset and configure the multimeter for continuity measurements. This command does not initiate the measurement. The range and resolution are fixed for continuity tests (1 k range and 51/2 digits). CONFigure:DIODe Preset and configure the multimeter for diode measurements. This command does not initiate the measurement. The range and resolution are fixed for diode tests (1 Vdc range with 1 mA current source output and 51/2 digits). Query the multimeter's present configuration and return a quoted string. 120 Chapter 4 Remote Interface Reference Measurement Configuration Commands Measurement Configuration Commands See also "Measurement Configuration, " starting on page 51 in chapter 3. FUNCtion "<function>" Select a measurement function. The function must be enclosed in quotes in the command string (FUNC "VOLT:DC"). Specify one of the following strings. VOLTage:DC VOLTage:DC:RATio VOLTage:AC CURRent:DC CURRent:AC RESistance (2-wire ohms) FRESistance (4-wire ohms) FREQuency PERiod CONTinuity DIODe FUNCtion?Query the measurement function and return a quoted string. <function>:RANGe {<range>|MINimum|MAXimum} Select the range for the selected function. For frequency and period measurements, ranging applies to the signal's input voltage, not its frequency (use FREQuency:VOLTage or PERiod:VOLTage). [. . . ] This corresponds to about 0. 0001% (1 ppm) of full scale, or 21 bits including the sign bit. All four specifications are equivalent. Accuracy Accuracy is a measure of the "exactness" to which the multimeter's measurement uncertainty can be determined relative to the calibration reference used. Absolute accuracy includes the multimeter's relative accuracy specification plus the known error of the calibration reference relative to national standards (such as the U. S. National Institute of Standards and Technology). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AGILENT TECHNOLOGIES 34401A

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AGILENT TECHNOLOGIES 34401A will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag