Detailed instructions for use are in the User's Guide.
[. . . ] Alcatel-Lucent 7450 ESS
EThErnET SErviCE SwiTCh | r E L E A S E 7. 0
The Alcatel-Lucent 7450 Ethernet Service Switch (ESS) is a high performance MPLS-enabled Carrier Ethernet platform providing high-speed Ethernet service delivery and high-density service aggregation at the Carrier Ethernet service edge. [. . . ] Each system offers leading throughput and density, the ability to mix and match a wide range of Ethernet and packet over SONET/SDH interface adapters, and exceptional portability of adapters across platforms. Alcatel-Lucent is committed to providing environmentally friendly solutions. Energy efficiency and environmental responsibility are built into the platform design, research and development programs, manufacturing processes, and life cycle management. As a result, the 7450 ESS delivers some of the highest levels of energy efficiency in the market and can play a major role in helping service providers reduce their overall energy consumption and carbon footprint.
Features
· Terabitroutingcapacitytomeet ever increasing bandwidth requirements in Carrier Ethernet networking environments ¬ Up to 1 Tb throughput (half duplex) in 1/3 of a telco rack ¬ 50 Gb/s (full duplex) slots with no tradeoff between terabit performance and advanced service delivery ¬ Migration path to multi-terabit system capacity with 100 Gb/s (full duplex) slots planned on existing system, leveraging breakthrough in-house developed FP2 silicon-- without a forklift upgrade · Awiderangeofhigh-density, flexible Ethernet and SONET/SDH interface options enabling costeffective Carrier Ethernet service delivery and aggregation ¬ Full compliment of 10M/100M/1G/ 10G Ethernet interfaces with SFP/ XFP/copper support - Up to 400 GigE ports/chassis; 1, 200 GigE ports/rack - Up to 80 10GigE ports/chassis; 240 10GigE ports/rack - Support for synchronous Ethernet (Sync-E) on MDA-XPs ¬ 10GigE MDA with integrated tunable DWDM optics and Sync-E support integrates transponders into the adapter ¬ 10GigE and GigE High-Scale MDA supports up to 20k subscribers with 160, 000 ingress queues and 160, 000 egress queues per adapter ¬ Flexible half-slot configurations for maximum resource use and minimized cost ¬ Mix-and-match interface types at the IOM level and/or between chassis ¬ SONET/SDH interface adapter options include the following multi-port SONET/SDH MDAs:
- OC-3c/STM-1c, OC12-c/STM-4c and OC-48c/STM-16c · ComprehensiveMPLS-enabledCarrier Ethernet to support a full range of residential, business and mobile service applications ¬ Advanced MPLS and IP feature set includes RSVP-TE, LDP, T-LDP, PWE3, fast reroute (FRR), OSPF, IS-IS and RIP ¬ Fully featured Layer 2 VPNs using VPLS, H-VPLS and VLLs ¬ Ethernet support includes IEEE 802. 1Q (VLAN tagging), IEEE 802. 1ad (QinQ or Stacked VLANs), IEEE 802. 1s (Multiple Spanning Tree), IEEE 802. 1w (Rapid Spanning Tree), IEEE 802. 1ah (Provider Backbone Bridges), synchronous Ethernet ¬ Seamless integration with IP/MPLS provider edge - Layer 2 VPNs over MPLS - Ethernet access to IP VPN and enhanced Internet services ¬ Layer 2 tunneling protocol (L2TP), point-to-point protocol (PPP) and BGP-based auto-discovery for VPLS. 7450 ESS chassis specifications
7450 ESS-12 7450 ESS-7 7450 ESS-6 7450 ESS-6v 7450 ESS-1
System throughput
·Switchfabric:Upto 1 Tb/s (half duplex) ·Slotcapacity:Upto 50 Gb/s (full duplex)
·Switchfabric:Upto 500 Gb/s (half duplex) ·Slotcapacity:Upto 50 Gb/s (full duplex)
·Switchfabric:Upto 320 Gb/s half duplex (non-redundant with graceful degradation); up to 160 Gb/s half duplex (fully redundant) ·Slotcapacity:Upto 40 Gb/s full duplex (non-redundant); up to 20 Gb/s full duplex (redundant) ·IOM-20G ·IOM3-XP ·Upto4perchassis ·Upto8Anymixof MDAorMDA-XP ·SF/CPM, PEM-3, fan ·SF/CPM, PEM-3, fan, IOM, MDA, ISA ·Height:35. 56cm(14in. ) ·Width:44. 5cm(17. 5in. ) ·Depth:64. 8cm(25. 6in. )
·Switchfabric:Upto 320 Gb/s half duplex (non-redundant with graceful degradation); up to 160 Gb/s half duplex (fully redundant) ·Slotcapacity:Upto 40 Gb/s full duplex (non-redundant with graceful degradation); up to 20 Gb/s full duplex (redundant) ·IOM-20G ·IOM3-XP ·Upto4perchassis ·Upto8Anymixof MDAorMDA-XP ·SF/CPM, PEM-3, fan ·SF/CPM, PEM-3, fan, IOM, MDA, ISA ·Height:80cm(31. 5in. ) ·Width:46. 5cm(18. 3in. ) ·Depth:45. 5cm(17. 9in. )
·Switchfabric:Upto 40 Gb/s (half duplex) ·MDAhalf-slotcapacity: Upto10Gb/s(full duplex)
IOM support
·IOM-20G ·IOM3-XP ·Upto10perchassis ·Upto20Anymixof MDAorMDA-XP ·SF/CPM, powerentry module-3(PEM-3), fan ·SF/CPM, PEM-3, fans, IOM, MDA, ISA
·IOM-20G ·IOM3-XP ·Upto5perchassis ·Upto10Anymixof MDAorMDA-XP ·SF/CPM, PEM-3, fan ·SF/CPM, PEM-3, fan, IOM, MDA, ISA
·OneintegratedIOM andSF/CPM ·Upto2Anymixof MDAorMDA-XP ·Power, fan ·IntegratedIOMand SF/CPM, MDAand power ·Height:6. 7cm(2. 6in. ) ·Width:44. 5cm(17. 5in. ) ·Depth:56. 4cm(22. 2in. )
Number of half-slot MDAs per chassis Common Equipment Redundancy Hot-swappable modules Dimensions
·Height:62. 2cm(24. 5in. ) ·Height:35. 56cm(14in. ) ·Width:44. 5cm(17. 5in. ) ·Width:44. 5cm(17. 5in. ) ·Depth: ·Depth:64. 8cm(25. 5in. ) ¬ ithoutcableguides: W 65. 4 cm (25. 75 in. ) ¬ ithcableguides: W 76. 5 cm (30. 1 in. ) ·Empty:33. 1kg(73lb) chassis weight with two fan trays and air filters ·Loaded:152kg(335lb) approx. ·-40VDCto-72VDC ·90Ato162A ·1+1redundancy
Weight
·Empty:27. 2kg(60lb) ·Empty:32. 7kg(72lb) chassis weight with 2 chassis weight with, fan trays and air filters PEMS, twofantrays and air filters ·Loaded:70. 5kg(155lb) approx. ·-40VDCto-72VDC ·52Ato93A ·1+1redundancy ·-40VDCto-72VDC ·41Ato75A ·1+1redundancy
·Empty:54. 4kg(119. 7lb) ·27. 22kg(60lb)chassis chassis weight with weight PEMs, fantraysand air filters ·Loaded:89kg(195. 8lb) approx. ·-40VDCto-72VDC ·41Ato75A ·1+1redundancy ·110VACor220VAC ·-40VDCto-72VDC ·10Ato6A ·1+1redundancy ·ACavailablewith external shelf ·Side-to-sideairflow
Power
Cooling
·Front-to-backairflow
·Side-to-backairflow
·Side-to-backairflow
·Front-bottomintake, rear top exhaust
Alcatel-Lucent 7450 ESS | Release 7. 0 | Data Sheet
5
Table 2. 7450 ESS MDA-XP and MDA port densities-by-chassistype
MDA TYPE ETHERNET MDA-XPs PORT COUNT INTERFACE TYPE ESS-1 ESS-6 /ESS-6v ESS-7 ESS-12
GigE 10/100/1000BASE-TX GigE 10GigE 10GigE 10GigE
ETHERNET MDA WITH TUNAblE OPTICS
20 20 10 4 2 1 1
SFP rJ-45 SFP XFP XFP XFP LC with Tunable DWDMOptics rJ-45 SFP rJ-45 SFP SFP XFP XFP XFP XFP/SFP SFP XFP SFP SFP SFP SFP SFP n/A
40 40 20 8 4 2 2
160 160 80 32 16 8 8
200 200 100 40 20 10 10
400 400 200 80 40 20 20
10GigE
ETHERNET MDAs
10/100BASE-TX 100BASE-FX 10/100/1000BASE-TX GigE GigE 10GBASE (LAn) 10GBASE (LAn/wAn) 10GBASE (LAn) 10GBASE+GigECombination(LAN)
HIgH SCAlE MDAs
60 20 20 20 10 2 1 1 1/10 10 1 16 8 16 4 2 n/A
120 40 40 40 20 4 2 2 2/20 20 2 32 16 32 8 4 2
480 160 200 160 80 16 8 8 8/80 80 8 128 64 128 32 16 8
600 200 200 200 100 20 10 10 10/100 100 10 160 80 160 40 20 10
1200 400 400 400 200 40 20 20 20/200 200 20 320 160 320 80 40 20
GigE 10GigE
POS MDAs
OC-3c/STM-1c OC-12c/STM-4c/OC-3c/STM-1c(Multirate) OC-12c/STM-4c/OC-3c/STM-1c(Multirate) OC-48c/STM-16c OC-48c/STM-16c
OTHER
versatile Service Adapter
Table 3. 7450 ESS ISA summary
ISA TYPE NOTES
Application Assurance iSA (AA-iSA) video iSA
7persystemwithN+1forredundancy 8 per system with load balancing
6
Alcatel-Lucent 7450 ESS | release 7. 0 | Data Sheet
Table 4. Alcatel-lucent 7450 ESS ordering information
PART NUMbER PART NAME DESCRIPTION
3hE04834AA
CH-BN7450ESS-12DC+SF/CPM-3BNDL
7450ESS-12DC+ESS-12SF/CPM-3Bundle. Includes:7450ESS-12DCintegratedchassis(1x 3HE02033BA)whichincludesredundantDCPEM-3s(2x3HE03666AA), impedancepanels(2 x3HE04150AA, 5perpack)andnon-redundant7450ESS-12SF/CPM-3(1x3HE03618AA). 7450ESS-7DC+SF/CPM-3Bundle. Includes:ESS-7DCintegratedchassis(1x3HE00387CB) whichincludesredundantDCPEM-3s(Slot-13HE03665AA&Slot23HE03664AA), impedance panels (1 x 3hE04150AA, 5 per pack), a high flow fan tray, fan filter and non-redundant 7450 ESS-7SF/CPM-3(1x3HE04166AA). [. . . ] The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein. [. . . ]