User manual ALPINE V12 ACCUCLASS-D SETUP

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ALPINE V12 ACCUCLASS-D. We hope that this ALPINE V12 ACCUCLASS-D user guide will be useful to you.

Lastmanuals help download the user guide ALPINE V12 ACCUCLASS-D.


Mode d'emploi ALPINE V12 ACCUCLASS-D
Download
Manual abstract: user guide ALPINE V12 ACCUCLASS-DSETUP

Detailed instructions for use are in the User's Guide.

[. . . ] Firstly, by setting the amplifier ID number (1-8), it allows the optional RACC (RUX-4280 Remote Amplifier Control Center) to identify each amplifier individually and in a specific order. Secondly, it provides a variable turn-on delay that can be used to minimize inrush current in large multi-amp systems, or to eliminate any turn-on "pop". NOTE: If using a RUX-4280 (RACC) with more than 1 AccuClass-D amplifier, be sure to set each amplifier with a different ID Number (1-8). Amplifiers with the same ID will cause the RACC to display "NO AMP. " STEP 9. (9) OUTPUT DISABLE Previously known as "Safe Mode", this feature provides a simple way to safely adjust the all DSP functions with the amplification circuit turned off, eliminating the possibility of speaker damage during setup. [. . . ] (3) SUBSONIC (Subsonic Filter) MODE SELECT 1 2 3 4 5 6 7 8 9 0 1 FUNCTION SELECT 1­1 2­1 3­1 4­1 5­1 6­1 7­1 8­1 9­1 0­1 0­2 8­2 1­2 2­2 3­2 4­2 5­2 6­2 4­3 4­4 is for only MRD-M1000. 1­3 BUTTON FLOW MODE ENT (DOWN) (UP) 2 3 4 LPF SUBSONIC PARAMETRIC EQ Subsonic filters are commonly used to minimize over excursion at very low frequencies, or to optimize output power by only amplifying frequencies that can be effectively reproduced. This feature is essentially a high pass filter with a very low frequency range, and is selectable from 15Hz to 50Hz in 5Hz increments. Please make sure that the frequency selected is significantly lower than that of the low pass filter, unless you have a very specific performance goal in mind. To the right is example [2], which illustrates the effect of a subsonic ADJUSTING THE SUBSONIC FILTER · You should be in mode "3" (SUBSONIC) now from the previous step. · Push "ENT" to enter "3". Push "ENT" to enter "3-1" (ON/OFF). · Toggle to "ON" setting and push "ENT". · Push "ENT" to enter "3-2" (FREQUENCY). · Typical settings include 25Hz for sealed box, and 30Hz or higher for ported box. (depending on tuning freq. ) · Press "MODE" to advance to step 4 below. START HERE 2 Lower Frequency (LPF) Higher Frequency 30Hz Sample Adjustment 0dB 10Hz 20 30 40 60 100K 1000K * 5­2 Toggle ENT ENT Toggle Hz For Sealed OR ENT ENT For Ported Hz MODE 5 6 7 8 9 0 BASS COMP. PHASE AMP SET OUTPUT DISABLE MEMORY T O S T E P 4 Proper configuration of the input setup menu is critical for source signal matching with minimal distortion, while also optimizing the output level relative to other amplifiers in the system. INPUT SELECT (mode 1-1) should be set according to the physical input signal connection being made, either "2ch" for stereo or "1ch" for single/mono channel. INPUT LEVEL (mode 1-2) allows the A/D converter's input to be optimized for the best possible signal clarity and volume range. Setting this overly sensitive or severely clipping the input can result in very high distortion, so it is best to use the clipping indicator as general guide. GAIN FACTOR (mode 1-3) is provided for special cases where additional gain is still required after all other adjustments have been made. While this signal shaping algorithm allows a higher average output level to be reached at lower source volumes, signal alteration may not be desirable in some applications. Therefore, it is recommended to return to this adjustment again later after continuing through the remaining setup steps. SETTING THE INPUT START HERE · Push "MODE" to access "1" (INPUT). · Push "ENT" enter "1". Push "ENT" to enter "1-1" (SELECT). · Toggle to select "1ch" or "2ch". MODE · Push "ENT" to enter "1-2" (INPUT LEVEL). · Toggle to the input level that will properly match the source unit output to the amplifier input. [. . . ] · Push "ENT" to enter "2-2" (FREQUENCY). · Push "MODE" to advance to step 3 below. Copyright 2002 © Alpine Electronics of America, Inc. START HERE 1 Lower Frequency (LP) Higher Frequency 80Hz Sample Adjustment 0dB STEP 5. (Bass Compensation) Digital Bass Compensation utilizes Alpine's exclusive MediaXpanderTM processing technology to enhance bass definition and output. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ALPINE V12 ACCUCLASS-D

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ALPINE V12 ACCUCLASS-D will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag