If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AMX AXB-REL8 RELAY CONTROLLER. We hope that this AMX AXB-REL8 RELAY CONTROLLER user guide will be useful to you.
Lastmanuals help download the user guide AMX AXB-REL8 RELAY CONTROLLER.
Manual abstract: user guide AMX AXB-REL8 RELAY CONTROLLER
Detailed instructions for use are in the User's Guide.
[. . . ] This limitation of liability will be effective even if AMX Corporation or an authorized representative of AMX Corporation has been advised of the possibility of any such damages. This limitation of liability, however, will not apply to claims for personal injury. Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or exclusion of incidental or consequential damages for consumer products. [. . . ] Suitable for stand-alone or rack mount applications, the AXB-REL8 may be used with AXCESS or AXCENT systems via the four-wire AXlink data bus.
Front and Rear Panels
The front and rear panels of the AXB-REL8 are shown in FIG. 1.
Device DIP switch Relay LEDs (1-8)
AXlink LED
AXlink DEVICE
ON
1
2
3
4
5
6
7
8
AXlink connector
8 PWR GND AXM AXP B A B 7 A
Relay contacts 5-8 (discrete commons)
6 B A B 5 A B 4 A B 3 A B 2 A B 1 A
Relay contacts 1-4 (shared commons)
AXlink
FIG. 1 AXB-REL8 front and rear views
Specifications
The following table details the specifications for the AXB-REL8 Axcess Relay Controller. Specifications
Dimensions (HWD) Enclosure Power Consumption Baseline draw With all 8 relays On Weight Included Accessories Optional Accessories · 90 mA @ 12 VDC (min) · 170 mA @ 12 VDC (max) 17. 50 oz. (496. 11 g) Metal tab strips included for external adjacent relay communing. AC-RK Accessory Rack Kit 1. 51" x 5. 55" x 5. 45" (3. 84 cm x 14. 10 cm x 13. 84 cm) Non-glare, high-impact black matte plastic
AXB-REL8 Axcess Relay Controller
1
Product Information
Specifications (Cont. )
Dimensions (HWD) Enclosure Power Consumption Baseline draw With all 8 relays On Front Panel Components AXlink Status indicator AXlink LED (green and blinks to indicate AXlink communication activity and power: · Full-Off indicates no power is being received or the controller is not functioning properly. · One blink per second indicates power is active and AXlink communication is functioning. · Full-On indicates there is no AXlink control or activity, but power is On. Device DIP switch Relay LEDs 1-8 (Red) Rear Panel Components AXlink connector Relay contacts Four-pin captive wire receives power and information via the AXlink bus and AXlink system controller. Eight (normally -open) isolated two-pin relay contacts 1 A @ 28 VAC or VDC: · Relays 1-4 can share a common if use jumper"A" pins with a tab strip · Relays 5-8 use discrete commons (wire commons individually) An eight-position DIP switch is used to set the device number for the AXB-REL8. Illuminate when associated relay is closed. Relay LED's should match panel control function. · 90 mA @ 12 VDC (min) · 170 mA @ 12 VDC (max) 1. 51" x 5. 55" x 5. 45" (3. 84 cm x 14. 10 cm x 13. 84 cm) Non-glare, high-impact black matte plastic
2
AXB-REL8 Axcess Relay Controller
Connection and Wiring
Connection and Wiring
Setting the DEVICE Dip Switch
The eight-position Device DIP switch is located on the front panel of the AXB-REL8 as shown in FIG. Each device in the AXlink bus must have a unique AXlink device number.
If you later change the device number, remove and reconnect the AXlink connector. This enters the new device number into memory. The device number takes effect only on power-up.
The device can be 1 of the 255 devices in an Axcess, AXCENT, AXCENT2, or AXCENT3 system. The device number must match the device assignment in the Axcess program. AMX assigns device numbers into the following three segments:
!!
Cards Boxes Panels
1 through 95 96 through 127 128 through 255
Set the device number by setting the DEVICE DIP switch. The device number is the total of all of the switches in the ON (down) position. The following table shows the switch numbers and their corresponding values. Device DIP switch settings
Position Value 1 1 2 2 3 4 4 8 5 16 6 32 7 64 8 128
As an example, the following DIP switch (FIG. [. . . ] Do not connect the optional +12 VDC power supply wire to the control system's power supply side of the AXlink connector (FIG. Checking the installation After set-up is complete: 1. Check cable numbers and wiring, interfaces and sources against supplied documentation. Install tab strips to jumper between shared commons and clip off excess tabs. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX AXB-REL8 RELAY CONTROLLER
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.