User manual AMX AXCENT3 AND AXCENT3 PRO INTEGRATED AXCESS SYSTEM

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AMX AXCENT3 AND AXCENT3 PRO INTEGRATED AXCESS SYSTEM. We hope that this AMX AXCENT3 AND AXCENT3 PRO INTEGRATED AXCESS SYSTEM user guide will be useful to you.

Lastmanuals help download the user guide AMX AXCENT3 AND AXCENT3 PRO INTEGRATED AXCESS SYSTEM.


Mode d'emploi AMX AXCENT3 AND AXCENT3 PRO INTEGRATED AXCESS SYSTEM
Download
Manual abstract: user guide AMX AXCENT3 AND AXCENT3 PRO INTEGRATED AXCESS SYSTEM

Detailed instructions for use are in the User's Guide.

[. . . ] instruction manual 3 Axcent Integrated Axcess Controllers and 3 Pro Axcent A x c e s s C e n t ra l C o n t r o l l e r s AMX Limited Warranty and Disclaimer AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX Corporation, with the following exceptions: · · · Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. Disk drive mechanisms, pan/tilt heads, power supplies, and MX Series products are warranted for a period of one (1) year. AMX Lighting products are guaranteed to switch on and off any load that is properly connected to our lighting products, as long as the AMX Lighting products are under warranty. AMX Corporation does guarantee the control of dimmable loads that are properly connected to our lighting products. [. . . ] CTOF sets the time between digits or any other pulse and CTON sets the pulse length for each digit. This is the time between digits, or pulses, that is associated with an SP command. Syntax: "'CTOF', <time>" Variables: <time> = 0 - 255 in tenths of a second; Time is stored in permanent memory. Example: SEND_COMMAND IR_1, "'CTOF', 10" Sets the channel's off-time pulse in tenths of a second. Time is stored in non-volatile RAM. 12 Axcent3 and Axcent3 Pro Integrated Axcess Controllers Axcess Programming Send_Commands for the IR/Serial/Data Ports (Cont. ) CTON Sets the IR pulse (single) on time for each channel digit and IR functions. CTON sets the pulse length for each digit and CTOF sets the time between digits or any other pulse. Syntax: "'CTON', <time>" Variables: <time> = 0 - 255 in tenths of a second; Time is stored in permanent memory. Example: SEND_COMMAND IR_1, "'CTON', 20" Sets the pulse length to 2 seconds. GET BAUD Gets the IR/Serial/ Data port's current communication parameters. The port sends the data through the master's PROGRAM port. Syntax: 'GET BAUD' Example: SEND_COMMAND IR_1, 'GET BAUD' System response example: Device 1, 38400, N, 8, 1 GET MODE Gets the IR/Serial/ Data port's current mode setting. Syntax: 'GET MODE' Example: SEND_COMMAND IR_1, 'GET MODE' System response example: Device 8 IR, CARRIER, IO LINK 0 IROFF Stops IR output on the designated device. Syntax: 'IROFF' Example: SEND_COMMAND IR_1, 'IROFF' Stops transmitting IR signals. POD Syntax: 'POD' Disables current PON (power on) or POF (power off) command settings. POF Syntax: 'POF' Sends IR function 28 (if available) or 9 to turn device power off. After three attempts, if the linked I/O channel still detects a power-on status, the controller starts processing stored buffer commands. Then, if another IR function 28 or 9 fails to turn the external device's power off, the controller sends a PUSH and RELEASE of channel 248 and generates a power failure error. If the device is turned on manually, this command turns the external device's power off unless a PON (power on) or POD (disable POF) command is received. PON Syntax: 'PON' Sends IR function 27 (if available) or 9 to turn device power on. After three attempts, if the linked I/O channel still detects a power-off status, the controller starts processing stored buffer commands. Then, if another IR function 27 or 9 fails to turn the external device's power on, the controller sends a PUSH and RELEASE of channel 248 and generates a power failure error. If the device is turned off manually, this command turns external device power on unless a POF (power off) or POD (disable 'PON' command) command is received. Axcent3 and Axcent3 Pro Integrated Axcess Controllers 13 Axcess Programming Send_Commands for the IR/Serial/Data Ports (Cont. ) PTOF Sets IR power-off pulse time after a power-on pulse in increments of . 10 seconds. [. . . ] Place the AMX SOFTROM diskette into drive A or B of your PC. At the MS-DOS prompt C:>, type A:\ and press the ENTER key. When the A:\> prompt appears on the screen, type SOFTROM and press the ENTER key. Configuration To configure the communication setting for the SOFTROM program: 1. Press F1 and the Configure screen appears. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX AXCENT3 AND AXCENT3 PRO INTEGRATED AXCESS SYSTEM

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX AXCENT3 AND AXCENT3 PRO INTEGRATED AXCESS SYSTEM will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag