User manual AMX AXF-S AXCESS SERVER CARDFRAME (WITH AXC-S CARD)

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AMX AXF-S AXCESS SERVER CARDFRAME (WITH AXC-S CARD). We hope that this AMX AXF-S AXCESS SERVER CARDFRAME (WITH AXC-S CARD) user guide will be useful to you.

Lastmanuals help download the user guide AMX AXF-S AXCESS SERVER CARDFRAME (WITH AXC-S CARD).


Mode d'emploi AMX AXF-S AXCESS SERVER CARDFRAME (WITH AXC-S CARD)
Download
Manual abstract: user guide AMX AXF-S AXCESS SERVER CARDFRAME (WITH AXC-S CARD)

Detailed instructions for use are in the User's Guide.

[. . . ] Reference Guide AXC-S CardFrame Server Card Overview The AXC-S CardFrame Server Card (FIG. 1) is a processor card that manages communication among control cards in a CardFrame. [. . . ] Apply power to the CardFrame and verify a "one-blink" pattern on the AXlink LED (CR1). Refer to the CR1 Specifications for more information on blink patterns. S1 DIP switch Handling grip FIG. 1 AXC-S Server Card (side view) Specifications AXC-S Specifications Power Processor Mounting Program Chip LED Indicators 30 mA @ 12 VDC Motorola MC68HC705 Inserts into the CS slot in an Axcess CardFrame Onboard OTP (One Time Programmable) chip · · · · CR1 (AXlink) indicates transmission of data Full On - indicates no communication with master Full Off - indicates no power being received by unit One blink/second - indicates normal operation AXLink Connector · Front connector used for AXlink communication. · Also used for daisy-chaining several CardFrames together. Setting the AXlink Device DIP switch (S5) The eight-position Device DIP switch (S1), shown in FIG. 2 assigns the value to the CardFrame using the AXC-S card. The Device DIP switch example is set to 1, the factory default setting. 2 DIP switch (S1) The AXlink device number range is 1-255. The Device DIP switch positions determines their values, based on the following table. Device DIP Switch (S1) Settings and Values Position Value 1 1 2 2 3 4 4 8 5 16 6 32 7 64 8 128 The dip switch sets the first address of the card frame with the other 15 slots following in order. For example: if set to one, the card frame addresses are set from 1 to 16. [. . . ] AMX reserves the right to alter specifications without notice at any time. 3000 research drive, richardson, TX 75082 USA · 469. 624. 8000 · 800. 222. 0193 · fax 469. 624. 7153 · technical support 800. 932. 6993 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX AXF-S AXCESS SERVER CARDFRAME (WITH AXC-S CARD)

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX AXF-S AXCESS SERVER CARDFRAME (WITH AXC-S CARD) will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag