User manual AMX UPC20+ UNIVERSAL POWERMOTOR CONTROLLER
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AMX UPC20+ UNIVERSAL POWERMOTOR CONTROLLER. We hope that this AMX UPC20+ UNIVERSAL POWERMOTOR CONTROLLER user guide will be useful to you.
Lastmanuals help download the user guide AMX UPC20+ UNIVERSAL POWERMOTOR CONTROLLER.
Manual abstract: user guide AMX UPC20+ UNIVERSAL POWERMOTOR CONTROLLER
Detailed instructions for use are in the User's Guide.
[. . . ] instruction manual
UPC20+
Universal Power Controller
Control System Accessories
AMX Limited Warranty and Disclaimer
AMX Corporation warrants its products to be free of defects in material and workmanship under normal use for three (3) years from the date of purchase from AMX Corporation, with the following exceptions: · · · · · Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch overlay components that are warranted for a period of one (1) year. Disk drive mechanisms, pan/tilt heads, power supplies, MX Series products, and KC Series products are warranted for a period of one (1) year. Unless otherwise specified, OEM and custom products are warranted for a period of one (1) year. Software is warranted for a period of ninety (90) days. [. . . ] · Motor Control mode alternates between the timed operation of the two power relays. · Power Control mode allows independent control of both power relays. Control Ports Input Power Switch (S1) Two 2400 W power relays. Total combined current through both relays is 20 Amps. · Set this switch according to the high voltage wiring that will be connected to terminals 5 and 6 on P1. Refer to the P1 Terminal Connections on page 9. · Set switch S1 to the line input voltage value used before applying power to the UPC20+. High Voltage Terminal Block (P1) High voltage input and output wiring for motor or power control. Low voltage and Control Terminal Block (P2) Jumper JP1 Test Switches (PB1 and PB2) Contact closure, open-collector or CMOS logic level remote control wiring. Inputs 5 - 8 are referenced to the common connection at pin 4. Sets control mode of the unit to contact closure or remote sensor serial data. Provides local operation of relays K1 and K2 for testing power circuits or motors connected to the relay terminals. User adjusted for setting relay release time between 0 and 90 seconds. Provides selection of control mode options. See the Motor Control Mode DIP Switch S2 Positions table on page 5 and the Control Input Wiring to Connector P2 Terminals table on page 5 for control mode settings. Metal with black matte finish, knockouts for conduit. · 8. 5" (10. 5" including flange) x 4. 5" x 2. 2" · (220 mm (270 including flange) x 110 mm x 60 mm) Weight Options 3. 0 lbs. (1. 4 kg) with flange 12 VDC power supply (for 277 VAC applications)
Motor Time Delay Potentiometer (R8) DIP Switch (S2)
Enclosure Dimension (HWD)
UPC20+ Universal Power Controller
3
Product Information
ATTENTION INSTALLER
FACTORY SET TO INOPERATIVE MODE
(UNIT WILL NOT WORK UNTIL DIP SWITCHES ARE SET)
SEE CHART ON LID TO SET DIP SWITCHES FOR ACTIVE MODE
FIG. 2 UPC20+ inoperative mode warning label
4
UPC20+ Universal Power Controller
Product Information
Control Options Modes
If UPC20+ is powered up when changes are made to Dip Switch settings, then power must be cycled before changes can take effect.
Motor Control mode The table list options and connections for motor control. DIP switch settings provide 1, 2 or 3 button remote control contact arrangements. This mode is typically used for screen and drape motor control. In motor control mode, only one power relay (motor) can be energized at a time. [. . . ] 1 on page 2 for the location of the Terminal Block P1 on the circuit board.
Neut Line Load Line Load #1 #2 #2 #1 #1 Line #1 in and Line to transformer are common. 6 5 Board Power 4 3 2 1 Terminal Block P1
FIG. 5 Dual circuit 120/240 VAC power wiring
12
UPC20+ Universal Power Controller
Installation
Dual circuit 277 VAC Dual circuit connections provide power from 277 VAC for fluorescent ballasts (FIG. Circuit board power is provided by a separate 120/240 VAC high voltage circuit, or 12 VDC connected to terminals 1 and 6 on the low voltage terminal block. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE AMX UPC20+ UNIVERSAL POWERMOTOR CONTROLLER
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AMX UPC20+ UNIVERSAL POWERMOTOR CONTROLLER will begin.