User manual AOPEN H800

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AOPEN H800. We hope that this AOPEN H800 user guide will be useful to you.

Lastmanuals help download the user guide AOPEN H800.


Mode d'emploi AOPEN H800
Download
Manual abstract: user guide AOPEN H800

Detailed instructions for use are in the User's Guide.

[. . . ] Introduction 1 Copyright Copyright © 2000 by AOpen Inc. No part of this document may be copied or reproduced in any form or by any means without the prior written consent of AOpen Inc. AOpen makes no warranties with respect to this documentation and disclaims any implied warranties of merchantability, quality, or fitness for any particular purpose. The information in this document is subject to change without notice. [. . . ] -The Ac mains single-cycle peak inrush current shall be limited to 80 amps cold, 100 amps warm measured at 132 Vrms, 60 Hz and coinciding with the AC main voltage peak. -The AC mains steady-state RMS input current shall be: 10 amps maximum / 115 Vrms, 60 Hz. 6. 0 amps maximum / 230 Vrms, 50 Hz. User's Guide 2-12 OUTPUT REQUIREMENTS OUTPUT VOLTAGE AND CURRENT MINIMUM LOAD *+3. 3V +5V +12V -12V -5V +5Vsb 0. 2A 2. 0A 0. 2A 0. 0A 0. 0A 0. 0A NORMAL LOAD 14. 0A 14. 0A 6. 0A 0. 4A 0. 15A 1. 0A MAXIMUM LOAD 10. 6/28A 40/28. 5A 15A 0. 8A 0. 3A 2. 0A LOAD REG. ¡Ó 5% ¡Ó 5% ¡Ó 5% ¡Ó 5% ¡Ó 5% ¡Ó 5% Parts Description RIPPLE & NOISE 50mV P-P 50mV P-P 120mV P-P 100mV P-P 100mV P-P 50mV P-P *OPTIONAL (1) +3. 3V &+5V total output not exceed 235 W. When +3. 3V is load to 28A, the +5V maximum load is 28. 5A. When +3. 3V is load to 10. 6A, the +5V maximum load is 40A. (2) +3. 3V &+5V & +12V total output not exceed 330 W. (3) All outputs shall be safety-isolated from the AC mains and share a common return. This common return must be connected to supply chassis. (4 )Voltages and ripple are measured at the load side of mating connectors with a 0. 1 uF monolithic ceramic capacitor paralleled by a 10 uF electrolytic capacitor across the measuring terminals. REGULATORY COMPLIANCE SAFETY REQUIREMENTS -CSA C22. 2 -UL 1950 -IEC 950 -TUV EN 60950 -NEMKO + CB REPORT DIELECTRIC STRENGTH -Primary to Frame Ground : 1800 Vac for 1 sec. -Primary to Secondary : 1800 Vac for 1 sec. INSULATION RESISTANCE -Primary to Secondary : 20 Meg. GROUND LEAKAGE CURRENT The power supply ground leakage current shall be less than 3. 5mA. EMISSION REQUIREMENTS H800 Server Chassis Parts Description 2-13 When testing the power supply must operate within the listed requirements. OTHER REQUIREMENTS COOLING With the fan voltage set to around 12 volts, the fan will deliver greater than 38 CFM with the power supply in open air. INPUT CONNECTIONS Refer to Mechanical Specifications for placement. The AC mains input are through a three-circuit IEC type connector mounted on the rear of the power supply chassis. RELIABILITY The power supply reliability, when calculated by MIL-HDBK-217; latest revision, are exceed 100. 000 hours with all output at maximum load and an ambient temperature of 25¢. Redundant 337W Power Supply The redundant 337W power comes with power cage, 337W main power & 2nd 337W main power (optional) Main power module 337W main power 337W Redundant power cage 337W main power X 2 pcs User's Guide 2-14 Parts Description 1 x 337W Main power only Support Redundant 337W x 2 2. 6. 2. 1. DPS-300AB-1A 337W redundant Main power module specification General description : This specification describes the performance characteristic of 337 watts Hot-swap redundant power unit with +5V, +12V, +3. 3V, -5V and ­12V DC outputs. Forced output current share : the SPS unit(DPS-300AB-1) is intended to work with cage unit(RPS-600A) to form a redundant power module. There are two configurations described as below : (1) One single power supply operation, It is configured as one cage unit ( Delta module name RPS-600A) compatible with one power supply unit ( Delta model name DPS-300AB-1) for single power supply operation (2) Dual power supplies redundant operation, It's configured with one cage unit ( RPS-600A) compatible with two units of power supply (DPS-300AB-1) for dual power supply current sharing operation. Under dual power supply redundant operation, the power supply's output current are controlled electronically so that both power supplies share the loads. Electrical Characteristics : (1) (2) (3) (4) Input voltage range: 90 Vac ~ 264 Vac, auto-range, single phase Input frequency range: 47 Hz to 63 Hz. [. . . ] For another assembly please follow up rack mount kits install manual for detail. Secure each slide tracks on top and bottom of the cover with three screws. Put the chassis into the rack mount. Release top cover Install rack mount kits User's Guide 3-8 Optional Parts Lists 3. 8. 3. 8. 1. Explosive View, parts and icon Explosive view ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 PARTS NAME ASS'Y L-CASE ACER 002( C ) H800 PANEL ASS'Y SIDE COVER HDD CAGE ASS'Y RAIL ASS'Y EMI COVER FDD RAIL WHEEL (OPTIONAL) FOOT HANDSET (OPTIONAL) LONG CARD HOLDER FAN COVER SLOT I/O SECC FAN Q'TY 1 1 2 1 2 6 2 2 4 1 2 1 7 1 ITEM 15 16 17 18 19 20 21 22 23 24 25 26 27 PARTS NAME SPRING EMI (LONG) BOX FOR H800 ACCESSORY ASSY I/O BRACKET A3. 2 POWER SUPPLY POWER BRACKET (OPTIONAL) FDD CABLE SIDE COVER HANDSET CABLE & LED SET FLOPPY FILTER POWER RESET INTRUSION ALARM Q'TY 8 1 1 1 1 1 1 3 1 1 1 1 1 H800 Server Chassis Optional Parts Lists 4-1 3. 8. 2. parts A FOOT STAND P/N : 60. 96512. 011 B FOOT BASE P/N : 42. 96504. 001 C MAIN BOARD I/O BRACKET A3. 2 P/N : 60. 96533. 001 D FAN COVER P/N : 42. 96514. 001 E FDD RAIL P/N : 34. 96508. 001 F RAIL P/N : 60. 96505. 001 G EMI COVER P/N : 34. 96504. 001 H THUMB SCREW P/N : 86. 2R526. AR5 I 2ND FAN 500mm 3PIN P/N : 60. 96526. 001 J ASS HDD CAGE WITH 8CM FAN P/N : 60. 96504. 001 ASS HDD CAGE WITHOUT FAN P/N : 60. 96504. 011 User's Guide 3-10 3. 8. 3. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AOPEN H800

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AOPEN H800 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag