User manual APC BACK-UPS ES 500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual APC BACK-UPS ES 500. We hope that this APC BACK-UPS ES 500 user guide will be useful to you.

Lastmanuals help download the user guide APC BACK-UPS ES 500.


Mode d'emploi APC BACK-UPS ES 500
Download
Manual abstract: user guide APC BACK-UPS ES 500

Detailed instructions for use are in the User's Guide.

[. . . ] These outlets do not provide power during a power outage. Connect a printer, fax machine or scanner to these outlets. For convenience, the Back-UPS provides a method for integral cable management (see below). The socket-outlet shall be installed near the equipment, and shall be easily accessible. Back-UPSTM ES 350/500 User's Manual 990-2101A 8/03 1 5 4 2 Placement Avoid placing the Back-UPS in direct sunlight, excessive heat, excessive humidity or in contact with fluids of any type. For convenience, the Back-UPS can be mounted on a wall (see Wall Mount of UPS on the back page). Battery Back Up Outlets (3) Surge Only Outlets (2) Cable Management Feature 1 4 7 * 2 5 8 0 3 6 9 # Modem/Phone/Fax Wall Outlet 5 Switch on the 6 Connect USB Cable Status Indicators and Alarms Back-UPS Note: Allow the Back-UPS to charge for a full eight hours prior to use. [. . . ] When ordering, please specify Battery Cartridge: 350 VA order RBC29, 500 VA order RBC30. 123 Place the unit on a flat surface. Press the battery cover latch and remove the battery cover. 4 Pull the battery out of the housing, exposing the battery wire and connector. Recycle the old battery. Transfer Voltage Adjustment (optional) In situations where the Back-UPS or connected equipment appears too sensitive to input voltage, it may be necessary to adjust the transfer voltage. This is a simple task requiring use of the front panel pushbutton. To adjust the transfer voltage, proceed as follows: 1. Plug the Back-UPS into the utility power source. The Back-UPS will be in a Standby Mode (no indicators lit). Press the front panel pushbutton fully inward for 10 seconds. All indicators on the Back-UPS will flash to acknowledge going into Programming Mode. The Back-UPS will then indicate its current Sensitivity Setting, as shown in the following table. 2 3 6 5 Indicators Flashing 1 (yellow) Sensitivity Setting Input Voltage Range (for utility operation) 160 - 278 Vac Use When Low 4 Input voltage is extremely low or high. Connected equipment is sensitive to voltage fluctuations (recommended). 2 (yellow, and red) 3 (yellow, red, and red) Medium (factory default) High 180 - 266 Vac 196 - 256 Vac 1 5 Connect the new battery to the battery connector. Place the battery into the housing. 6 Slide the tabs on the battery cover into the slots in the chassis. Push the battery cover downward until the battery cover latchs to the housing. 4. To select the Low Sensitivity setting, press the pushbutton until the yellow indicator is flashing. To select the Medium Sensitivity setting, press the pushbutton until the yellow and red indicators are flashing. To select the High Sensitivity setting, press the pushbutton until yellow and both red indicators are flashing. To exit without changing the Sensitivity Setting, press the pushbutton until the green indicator is flashing. Once in Programming Mode, if the pushbutton is not pressed within 5 seconds, the Back-UPS will exit Programming Mode; all indicators will extinguish. APC and Back-UPS are registered trademarks of American Power Conversion. All other trademarks are property of their respective owners. Troubleshooting Use the tables below to solve minor Back-UPS installation and operation problems. Consult APC On-line Technical Support or call APC Technical Support for assistance with problems that cannot be resolved using this document: Possible Cause Procedure Specifications Input Voltage (on line) Frequency Limits (on line) On Battery Waveshape Maximum Load Check that the Back-UPS power plug is securely connected to the wall outlet. [. . . ] If the original packing is not available, ask customer service about obtaining a new set. Pack the UPS properly to avoid damage in transit. Note: Never use StyrofoamTM beads for packaging. Damage sustained in transit is not covered under warranty (insuring the package for full value is recommended). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE APC BACK-UPS ES 500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual APC BACK-UPS ES 500 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag