User manual APC BACK-UPS PRO 1500VA 230V CEE 75

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual APC BACK-UPS PRO 1500VA 230V CEE 75. We hope that this APC BACK-UPS PRO 1500VA 230V CEE 75 user guide will be useful to you.

Lastmanuals help download the user guide APC BACK-UPS PRO 1500VA 230V CEE 75.


Mode d'emploi APC BACK-UPS PRO 1500VA 230V CEE 75
Download
Manual abstract: user guide APC BACK-UPS PRO 1500VA 230V CEE 75

Detailed instructions for use are in the User's Guide.

[. . . ] See "System Faults" on page 4. Mute--The audible alarm has been turned off. Replace Battery--The battery is not connected or is nearing the end of its useful life. On Battery--The unit is supplying battery backup power to the connected equipment, it will beep four times every 30 seconds. 2 bu002 b Back-UPS® RS Installation and Operation bu046a Install PowerChute® Personal Edition software 1. Connect the supplied USB software interface cable to the data port, and the other end to a computer with access to the internet. Modes of operation Press DISPLAY to scroll through the display screens. [. . . ] 2. Power-Saving Mode: Press and hold DISPLAY for two seconds. The LCD will darken and the unit will beep to confirm the Power-Saving mode. While in Power-Saving Mode, the LCD will illuminate if a button is pressed, it then darkens after 60 seconds of no activity. Back-UPS® RS Installation and Operation 3 Unit sensitivity Adjust the sensitivity of the UPS to control when it will switch to battery power; the higher the sensitivity, the more often the unit will switch to battery power. 1. Ensure the unit is connected to utility power, but is OFF. 2. Press and hold the POWER button for six seconds. The LOAD CAPACITY bar will flash on and off, indicating that the unit is in programming mode. 3. Press POWER again to rotate through the menu options. The unit will beep to confirm the selection. Low sensitivity Medium sensitivity High sensitivity 156-288 Vac 176-282 Vac 176-276 Vac Input voltage is extremely low or The Back-UPS frequently switches to The connected equipment is high. computer loads. ) Warnings and System Faults Warnings Press DISPLAY to scroll through the display screens. Warning 1 ON LINE overload condition, indicated by the illuminated ON LINE icon, and the flashing overload icon. Warning 3 In ON LINE mode, and there is a bad battery, indicated by the flashing icon. Warning 2 Backup battery (ON BATT) Warning 4 overload condition. This is indicated by the flashing overload icon. The battery charge is low, and the Battery Charge indicator bar is flashing. System Faults The unit will display the fault messages. Contact APC Technical Support for additional support. · F01 - On-Battery Overload · F02 - On-Battery Output Short · F03 - On-Battery Xcap Overload · F04 - Clamp Short · F05 - Charge Fault · F06 - Relay Welding · F07 - Temperature · F08 - Fan Fault · F09 - Internal Fault 4 Back-UPS® RS Installation and Operation bu021a Function Button Quick-Reference Function Power Power On Timing Button (seconds) 0. 2 UPS Status Off Description Press POWER to start receiving input utility power. If A/C input power is not available, the unit will run on battery power. Ensure that the plug is fully inserted into the wall outlet. Ensure that the wall outlet is receiving utility power by checking it with another device. Adjust the transfer voltage and sensitivity range. The unit does not provide power during a utility power outage. The unit is operating on The plug has partially pulled out of the wall battery power, while connected outlet, the wall outlet is no longer receiving to utility power. utility power, or the circuit breaker has been tripped. The unit is performing an automatic self test. The utility input voltage is out of range, the frequency is out of range, or the waveform is distorted. The unit does not provide the Battery Backup outlets may be fully or expected amount of backup improperly loaded. The battery was recently discharged due to a power outage and has not fully recharged. The battery has reached the end of its useful life. The REPLACE BATTERY The battery has reached the end of its useful indicator is illuminated. [. . . ] If the Back-UPS requires service, do not return it to the dealer. 1. Consult the Troubleshooting section to eliminate common problems. 2. If the problem persists, go to http://www. apc. com/support/. 3. If the problem still persists, contact APC Technical Support. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE APC BACK-UPS PRO 1500VA 230V CEE 75

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual APC BACK-UPS PRO 1500VA 230V CEE 75 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag