User manual APC SMART-UPS 1000VA LCD 230V

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual APC SMART-UPS 1000VA LCD 230V. We hope that this APC SMART-UPS 1000VA LCD 230V user guide will be useful to you.

Lastmanuals help download the user guide APC SMART-UPS 1000VA LCD 230V.


Mode d'emploi APC SMART-UPS 1000VA LCD 230V
Download
Manual abstract: user guide APC SMART-UPS 1000VA LCD 230V

Detailed instructions for use are in the User's Guide.

[. . . ] Future service or storage issues may arise and require reference to this manual. Cette notice contient des instructions importantes concernant la sécurité. Radio frequency interference Warning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. [. . . ] This is useful where nominal input voltage is 110 to 115 Vac. s 220/230/240 Vac version The UPS's factory-set on-battery output voltage and input voltage limits for on-line and SmartBoost operation are designed for use in regions where the nominal line voltage is 220 to 230 Vac. When Option Switch 2 is set to the on ( I ) position, the upper and lower transfer voltages are raised by 4% and centered on a nominal input of 240 Vac. In addition, the on-battery output voltage is increased to 240 Vac. 5. 5. 3 Option Switch 3 When Option Switch 3 is set to the on ( I ) position, the UPS's audible alarm is disabled for the first 30 seconds of on-battery operation. This function is useful where brief power interruptions are frequent and cause the alarm to become annoying. 5. 5. 4 Option Switch 4 When Option Switch 4 is set to the on ( I ) position, the UPS's low-battery alarm interval is extended from 2 minutes (factory setting) to 5 minutes. This function is useful if the UPS is protecting a computer system that requires more than 2 minutes warning to perform a graceful shutdown. 20 5. 0 Operation 5. 6 Extended capabilities Sections 5. 6. 1 through 5. 6. 4 briefly describe the UPS's extended capabilities--advanced functions accessed using a computer running optional PowerDoctor or PowerChute plus UPS monitoring software. Refer to the monitoring software documentation for more information on these functions. Note: The extended capabilities of the UPS and operation of UPS monitoring software may be subject to change without notice. 5. 6. 1 Status reporting s General The UPS reports its electronics serial number, version number, date of manufacture, and date of last battery replacement. s Operating status The UPS reports its current operating status including on-line, on-battery, SmartBoost, overloaded output, low battery, shut down, and internal fault. s Test results The UPS reports the results of the last battery test. You may also test the operation of the UPS's visual and audible indicators. 5. 6. 2 Monitoring s Run time When on-battery, the UPS continuously monitors the remaining run time in minutes. 9. 2. ) s On-battery output voltage (220/230/240 Vac version only) You may set the UPS's on-battery output voltage to a nominal 220, 225, 230 or 240 Vac. s Utility failure sensitivity You may configure the UPS's sensitivity to line-voltage distortions to allow use of the UPS in different electrical environments. You may choose high, medium, or low sensitivity settings. The high setting provides the best protection from all utility voltage distortions. The medium setting is intended for use where rapid low-amplitude line voltage fluctuations occur frequently as the result of motor load switching in air conditioners, elevators, etc. The low setting is intended for use when the UPS is operated from an inexpensive fuel powered generator. s Low battery warning interval The UPS's low battery warning may be set to activate 2, 5, 7 or 10 minutes before shutdown. The default is 2 minutes. 23 5. 0 Operation s Audible alarm operation The UPS's audible alarm beeps four times every 30 seconds during onbattery operation. The alarm beeps continuously when low-battery conditions are reached. You may configure the audible alarm operation such that response to utility failure is delayed by 30 seconds, silenced until low-battery conditions are reached, or muted during both on-battery and low-battery conditions. s Minimum battery capacity to restart You may configure the UPS so that it will not restart upon restoration of the utility until the battery has been recharged to 0%, 10%, 75%, 90%, or 100% of capacity. [. . . ] color monitor NEC PowerMate 386 w/VGA monitor Gateway PS-60 Pentium w/monitor Gateway 4DX2-66E w/19-in. color monitor Dell System 433TE w/VGA monitor Compaq 486/33 w/19-in. color monitor Compaq DeskPro 486/25 w/VGA monitor Apple Quadra 900 w/21-in. color monitor Compaq 386/25 w/VGA monitor Apple Macintosh IIci w/two-page monitor Two Dell 486 MXs w/monitors Two Compaq 386/25s w/VGA monitors VA = volt-amperes; 0. 67 VA = 1 Watt. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE APC SMART-UPS 1000VA LCD 230V

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual APC SMART-UPS 1000VA LCD 230V will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag