[. . . ] SHOWER HANDBOOK
IMPORTANT: Please retain this booklet for future reference
CONTENTS
How to use your shower How your shower works What to do if things go wrong Installation instructions How to maintain your shower Guarantee Page . . . . . . . . . . . . . . . Ensure the electricity and water are turned on to the unit Function of controls : KNOB "A" Power selector. (On/off 600 only)
KNOB "B"
Adjusts the flow / temperature of the water
BUTTON "C" Starts and `Shuts down' the shower and cools the water automatically for (620 only) the next shower. Turning the unit on Model 600 Rotate knob "A" clockwise a ¼ turn (one click) this will select full power, the normal setting, further turns change the power setting (see above). [. . . ] All water contains particles of lime, which build up in the showerhead and unit reducing the performance. It is therefore important to clean the showerhead by regularly rubbing the rubber spray nozzles or, in severe cases dipping the spray plate into a suitable de-scaling solution. The frequency of this will vary from weekly to quarterly depending on the water hardness and 4 experience.
Check the spray plate is then free to rotate to give the three settings. In some winter conditions, when the incoming mains water is particularly cold it may be necessary to select the inner or outer spray pattern only. This will ensure correct operation of the shower with a slightly lower water flow rate Note: After use it is normal for some water to drip from the showerhead for a few moments, this inhibits scale build up over prolonged use.
What to do if things go wrong
SELF HELP If the shower is unsatisfactory, make the following checks before calling out the contractor. Any of these adjustments could restore the performance a) Water too HOT Increase water flow by adjusting the temperature control clockwise. (Select outer or combination spray patterns). Check hose is not kinked restricting the water flow. Decrease water flow by adjusting the temperature control anti-clockwise. Select inner or outer spray patterns only. Check water pressure has not fallen so far as to let pressure switch cut out, e. g. Please contact our spares department on 0870 0102 829. Fitting instructions are provided with spares.
b) Water too COLD
c) Spray pattern poor d) Water goes cold while using shower
e) Broken parts
PROFESSIONAL SERVICE If the previous checks fail to restore the performance, you should either contact the Redring Technical Advisory Service or seek the assistance of a qualified plumber and / or electrician. The person who installed the shower is probably the best one to repair it and is certainly the person to contact if you have a problem in the guarantee period. The following additional checklist is provided for the benefit of the qualified serviceman. WARNING SWITCH OFF THE ELECTRICITY AT THE ISOLATING SWITCH BEFORE REMOVING THE COVER TO MAKE CHECKS.
5
a) Water too HOT
b) Water too COLD
c) Water leaks from burst pressure relief valve d) Water does not flow when Knob "A" is rotated (when button "C" is pressed 620 only)
Water flow restricted by blockage in filter of solenoid valve. Switch off water and undo plastic nut on elbow, loosen brass nut to swing elbow away from solenoid. Remove filter in solenoid with long nosed pliers and flush clean. Check circuit through thermal cut-out Check circuit through microswitch on the pressure switch Check each element circuit. Check tightness of electrical connections. Check for cause of high pressure and remove it. Blockage on outlet or blocked spray plate. [. . . ] TAKE CARE TO AVOID RESTRICTING THE OUTLET AND FLOW FROM THE HANDSET OR THE PRESSURE RELIEF DEVICE. d) Electrical Connections The electrical installation must be in accordance with the current BS. The shower is designed for a single-phase A. C. Please check the rating plate on the unit to see what details apply. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE APPLIED ENERGY 600
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.