If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual APPLIED ENERGY DIGITEMP. We hope that this APPLIED ENERGY DIGITEMP user guide will be useful to you.
Lastmanuals help download the user guide APPLIED ENERGY DIGITEMP.
Manual abstract: user guide APPLIED ENERGY DIGITEMP
Detailed instructions for use are in the User's Guide.
[. . . ] UK: Xpelair have a comprehensive range of services including: · Free design service and technical advice on all aspects of ventilation from trained engineers. · Service and maintenance contracts to suit all requirements. · Xpelair Technical Hotline:- +44 (0) 8709 000430 · Xpelair Technical Faxline:- +44 (0) 8709 000530 Head Office, UK Sales Office and Spares Applied Energy Products Ltd, Morley Way, Peterborough, PE2 9JJ England Telephone: Fax: Sales/Spares Hotline: Sales/Spares Faxline: +44 +44 +44 +44 (0) (0) (0) (0) 1733 1733 8709 8709 456789 310606 000420 000520
Part No. 567 2026 01 (Revision D)
Xodus Toilet/Bathroom Fans DIGITEMP, DIGITEMPP & DIGITEMPT installation & operating instructions. [. . . ] · Operate the fan using an integral pull cord. · Built-in timer operates fan for a preset delay of 20 minutes.
If installing in a window or panel
1. Cut a hole, 125mm in diameter or if installing in a window, obtain a ready cut pane. The centre of the hole should be at least 110mm away from the edge of the panel or pane of glass.
· A double pole isolating switch with a minimum contact gap of 3mm in each pole (wall or ceiling mounted). · If metal switch boxes are used, earthing regulations must be followed. · Suitably rated 2-core cable - DIGITEMP / DIGITEMPP. · Suitably rated 3-core cable - DIGITEMPT. · 3mm electricians screwdriver and No. 8 wall screws and plugs or appropriate fasteners. · A wall or ceiling on/off switch - DIGITEMPT. It is recommended to use a switch with an indicator light. Feed the mains cable entry hole in the backplate to the terminals (Fig C). If wiring from above, leave the cable free to be fitted into labyrinth. Insert the lip of the back plate into the wall duct/ceiling or vent shaft as before. Fasten the back plate to the wall/ceiling or vent shaft using appropriate fasteners. If installing in a wall, a CFWG100 Wall Grille is required. Follow instructions provided.
For example:
1. If installing in a vent, an XXVK4 Vent Kit is required. · At least 110mm from the edges of the wall mounting surface to the centre of the hole. · As far away as possible from and opposite to the main source of air replacement to ensure airflow across the room (eg. · Near the source of steam or odours. · Not where ambient temperatures are likely to exceed 50oC. [. . . ] If installing in a window or panel no more than 9mm thick, a XXGK4 Glass Kit is required. Follow instructions supplied.
Wire the electrical connections
· Make sure the mains supply is isolated. · All wiring and installation must be supervised by a qualified electrician. Feed the cable between the two raised pegs, if wiring from above, and through labyrinth to terminal block. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE APPLIED ENERGY DIGITEMP
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.