If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual APPLIED ENERGY EXPRESSIONS 500S. We hope that this APPLIED ENERGY EXPRESSIONS 500S user guide will be useful to you.
Lastmanuals help download the user guide APPLIED ENERGY EXPRESSIONS 500S.
Manual abstract: user guide APPLIED ENERGY EXPRESSIONS 500S
Detailed instructions for use are in the User's Guide.
[. . . ] REDRING EXPRESSIONS 500S SMART TECHNOLOGY ELECTRIC SHOWER Installation and User Guide
IMPORTANT: This booklet should be left with the user after installation and demonstration
CONTENTS
Section Page Introduction _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 Important Safety Information _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 2 How to use your Expressions 500S Shower (Detailed) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3 How your Expressions 500S Shower Works _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 4 How to maintain your Expressions 500S Shower _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 5 What to do if things go wrong (1) Self Help _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 5 What to do if things go wrong (2) Professional Service _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 6 Redring After Sales Service _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 6 How to install your Expressions 500S Shower _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 7 Additional Accessories and Spare Parts _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 10 Guarantee and Contact Details _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 11 How to use your Expressions 500S Shower (Summary) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 12
INTRODUCTION
Thank you for purchasing a quality Redring Expressions 500S Shower manufactured in England. To enjoy your new shower at its best, please take time to read this manual thoroughly, and having done so, keep it handy for future reference. The Redring Expressions 500S is an electric shower incorporating our "Smart Technology" with a "Set and Forget" function of a push-button start/stop facility which starts the shower at a pre-set power and flow rate reducing the amount of adjustment required. Your shower is designed to stabilise temperature changes caused by water pressure fluctuations. [. . . ] "Med (medium)" setting may need to be selected. Check hose is not kinked restricting the water flow. Check power is on by neon being illuminated. Decrease water flow by adjusting Knob "C" anti-clockwise (direction of the "red arrows"). "High" setting may need to be selected. Select inner or outer only handset spray pattern. Thermal cut-out has operated after previous use ("Overheat" light is on) (automatically resets when unit cools down) "High" setting may need to be selected. Check water pressure has not fallen so far as to let pressure switch cut out, e. g. Raise position of shower handset.
Water too HOT
Water too COLD
Spray pattern poor Water takes longer to heat up Water goes cold while using shower
5
Water continues to flow when button "B" pressed Broken parts
This is normal. RING 08709 000420 (UK ONLY) Remember to quote the exact type of shower, as written on the front of the shower and on this leaflet.
6
The model and serial number are located on the bottom face of the shower. Make a note of those numbers here, and be sure to quote them if you call for advice. Model Number: 53-67_ _ _ _ _ _ _ _ _ _ _ _ _ Serial Number: _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
HOW TO INSTALL YOUR EXPRESSIONS 500S SHOWER
WARNING: ALL WIRING AND INSTALLATION MUST BE SUPERVISED BY A SUITABLY QUALIFIED PERSON. WARNING: DO NOT INSTALL THIS SHOWER WHERE IT MAY BE SUBJECTED TO FREEZING CONDITIONS We recommend that the installation is done in the following sequence. Position the riser rail at the height recommended in diagram 5 and mark its position (also see separate accessories fitting instructions). Position the heater so that the top of the unit is horizontal and level with, or a maximum of 0. 6 metres (2ft) below the top of the riser rail. Choose a flat piece of wall to avoid the possibility of distorting the backplate thus making the front cover a poor fit. Adjust the position to get the most convenient arrangement taking the following into account. · The possible need to use the handset over the sink for hair washing etc. · · The heater must not be mounted in the direct spray from the handset. The handset must not be able to come into contact with used water in the cubicle, bath or basin. If it can, even after the hose has been retained by the soap dish (see separate accessories fitting instructions sheet) then a vacuum breaker must be fitted.
4. Fix the riser rail with screws provided (see separate instructions supplied with accessories).
5. [. . . ] Press the start / stop button "B". This will turn the shower on, the water will flow and the indicator lights will glow showing chosen Power Selection. Knob "A" controls the power selection. Select "High", "Med (medium)" or "Cold" 4. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE APPLIED ENERGY EXPRESSIONS 500S
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.