User manual APPLIED ENERGY EXPRESSIONS 520TS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual APPLIED ENERGY EXPRESSIONS 520TS. We hope that this APPLIED ENERGY EXPRESSIONS 520TS user guide will be useful to you.

Lastmanuals help download the user guide APPLIED ENERGY EXPRESSIONS 520TS.


Mode d'emploi APPLIED ENERGY EXPRESSIONS 520TS
Download
Manual abstract: user guide APPLIED ENERGY EXPRESSIONS 520TS

Detailed instructions for use are in the User's Guide.

[. . . ] ® 520M/520TS Manual and Thermostatic Power Shower Units Installation instructions & User guide IMPORTANT: This booklet should be given to the customer after installation and demonstration. WARNING: Under no circumstances should this unit be connected to the mains water supply. Thank you for choosing a quality 'Redring' product manufactured in Peterborough, England. CONTENTS Information for the user Important Safety Instructions How to use your 'Redring' power shower How to maintain your 'Redring' power shower What to do if things go wrong Additional accessories Information for the installer Fixing the shower to the wall Plumbing Electrical Guarantee Page 2 2 4 4 10 5 6 9 12 HOW TO USE YOUR 'REDRING' POWER SHOWER 1. Ensure the electricity and water supplies are turned on to the unit. [. . . ] Choose a flat piece of wall to avoid possibility of distorting the backplate thus making the front cover a poor fit. Adjust the positions to get the most convenient arrangement taking the following into account : The possible need to use the handset over the sink for hair washing etc. The shower unit must not be mounted in the direct spray from the handset. The handset must not be able to come into contact with the used water in the cubicle, bath or basin. If it can, even after the hose has been retained by the hose retainer (see diagram 12), then a vacuum breaker must be fitted. It should be noted that these devices are liable to minor leakage so they must be positioned so that any drips are not detrimental Fix the riser rail with screws provided. The fixing holes at the base of the brackets will be revealed by removing the plastic fronts. Decide the position of the electrical cable to the unit. If top or bottom entry is chosen, carefully cut away the relevant walls of the backplate as shown in diagram 7. Decide the position of the water pipes into the unit. If top or bottom entry is chosen, carefully cut away the relevant walls of the backplate as shown in diagram 7. If bottom entry is chosen refer to note 8 in the plumbing section. If you have not yet done so, remove the front cover by undoing the retaining screws at the top and bottom of the unit. Remove Temperature Control Knob 'B' cap (see dia. 1) by levering out carefully with a small flat bladed screwdriver and remove the small fixing screw as shown in diagram 14. Your shower is provided with four fixing positions in the backplate (see diag. The top fixing holes are key-hole slots and the most convenient should be marked and drilled first. Tighten top screw with head protruding about 10 mm from the wall and hook the backplate over the screw head. This allows for correct and accurate alignment of your shower before marking and fixing the bottom positions. You may not wish to tighten up the screws at this stage as the holes are elongated to allow adjustment after other connections have taken place. Diagram 14 Small fixing screw Temperature limiter (visible when knob 'B' removed) B) Plumbing WARNING : - UNDER NO CIRCUMSTANCES SHOULD THIS UNIT BE CONNECTED TO THE MAINS COLD WATER SUPPLY. The shower unit should be connected to a gravity fed water supply from a static cold water cistern with a minimum capacity of 114 litres (25 galls). There must be a minimum head of water of 8. 0cm (3'') and a maximum head of 10. 0 metres (33ft). [. . . ] e) That the motor turns off and water stops flowing in the STOP position of knob 'A' 7. PLEASE DEMONSTRATE OPERATION TO THE USER. Please leave these instructions with the user for future reference. FILTER REMOVAL AND REFITTING. Inlet filters have been incorporated in the design of the Expression power shower which protect the internal mechanisms of the shower unit and the handset. If the performance of the shower deteriorates (ie. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE APPLIED ENERGY EXPRESSIONS 520TS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual APPLIED ENERGY EXPRESSIONS 520TS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag