If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual APPLIED ENERGY MW-EW 15. We hope that this APPLIED ENERGY MW-EW 15 user guide will be useful to you.
Lastmanuals help download the user guide APPLIED ENERGY MW-EW 15.
Manual abstract: user guide APPLIED ENERGY MW-EW 15
Detailed instructions for use are in the User's Guide.
[. . . ] If we are called out to investigate a fault, which is subsequently identified as being an installation fault, we will make a charge. It is important that the routine checks are completed before calling us out, as many issues can be simply diagnosed and resolved. We make no guarantees as to response times for repairs. We will endeavour to achieve the most timely response possible but while we indicate an average response time, this should not be taken as a guarantee. [. . . ] This guarantee covers products supplied by Applied Energy Products only, and does not cover other products and components used to create a system that have not been purchased from Applied Energy Products. The responsibility for the suitability of the complete system for the specific application remains the responsibility of the original specification engineer. This guarantee does not affect your statutory rights.
R
R
Xplus Ultra DC
Continuous extract MEV unit Xplus 250DC 8CV Xplus 400DC 8CV
Applied Energy Products Ltd Morley Way Peterborough PE2 9JJ tel 01733 456789 fax 01733 310606 Technical line 08709 000430 Technical fax 08709 000530
Xpelair is a registered trademark of Applied Energy Products Limited. Applied Energy Products reserve the right to alter product specifications or appearance without prior notice. All finishes and diagrams in this booklet are as accurate as printing processes allow.
8
Leaflet Part No. 23155AA (Revision B)
This page has been left blank for the addition of any notes you may wish to make
2
7
This page has been left blank for the addition of any notes you may wish to make.
Xpelair Continuous extract MEV unit
Installation and Operating Instructions
PLEASE LEAVE THIS LEAFLET WITH THE FAN, FOR THE BENEFIT OF THE USER
IMPORTANT
READ ALL THESE INSTRUCTIONS & WARNINGS FULLY BEFORE COMMENCING INSTALLATION. These appliances are intended for connection to fixed wiring. Check that the electrical rating shown on the products matches the mains supply. WARNING: THIS PRODUCT IS FOR CONNECTION TO 1 PHASE SUPPLY ONLY, DO NOT CONNECT TO 3 PHASE SUPPLY. WARNING: THIS APPLIANCE MUST BE EARTHED. All installations must be supervised by a qualified electrician. The fan should be set to provide the performance requirements according to the dwelling size by adjusting the switch on the side of the unit. The unit must be powered off if switch adjustment needs to be made. Altering the switch position when the unit is powered will not change the speed setting. The fan has 8 speed settings: Setting 1 2 3 4 5 6 7 8 Performance (m³/h) Xplus 250 Xplus 400 48m³/h 78m³/h 93m³/h 100m³/h 156m³/h 170m³/h 174m³/h 229m³/h 206m³/h 236m³/h 243m³/h 254m³/h 304m³/h 333m³/h 341m³/h 389m³/h
The fan provides constant volume performance for system pressures up to 300Pa
Cleaning
The fan can be mounted to a suitably strong wall or roof member.
Position of the air outlet
At least 0. 5m away from open door or window, or the inlet of another ventilation device.
Installing the ducting
1.
Detach the appropriate inlet covers after removing the fixing screws. Note: do not detach cover from any inlet not being used. Install the ducting to connect the fan to the air intakes and to the outlet. If the ducting is suspended, ensure that it is adequately supported. Fit intake and outlet grilles as required. If installing in a position where condensation is likely to run back towards the fan, install a condensation trap as near to the fan as possible.
Mounting the fan
Description
Xplus 250DC 8CV / Xplus 400DC 8CV
1. Before cleaning isolate completely from the mains supply. Wipe the inlet covers carefully with a damp cloth. [. . . ] Wipe the inlet covers carefully with a damp cloth. Apart from cleaning, no other maintenance is required.
Choice of 8 extraction speeds, selectable at installation according to house size. Boost speed available at each extraction speed when used with an appropriate controller (not supplied). Three 125mm diameter inlet spigot connections and a 125mm diameter outlet.
2.
3. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE APPLIED ENERGY MW-EW 15
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.