Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual APPLIED ENERGY XIL125T. We hope that this APPLIED ENERGY XIL125T user guide will be useful to you.
Lastmanuals help download the user guide APPLIED ENERGY XIL125T.
Manual abstract: user guide APPLIED ENERGY XIL125T
Detailed instructions for use are in the User's Guide.
[. . . ] The fan shall conform to Building Regulations for use in toilets, bathrooms and utility rooms. The fan shall incorporate an automatic air operated backdraught shutter · The unit shall be suitable for zone 1 and zone 2 requirements as defined by IEE Wiring Regulations 16th Edition BS 7674:2001 · A rectangular cut out section shall be provided in the top of the fan housing to connect to Xpelair Profile kit Ref. 90547AA · The housing and stylish air inlet shall be moulded in high gloss white ABS · The front cover shall be held in position by the retaining clips to facilitate removal and adjustment · The motor shall be totally enclosed, fitted with sealed self aligning maintenance free bearings and include thermal overload protection · Dimensions shall be W x H x D 222 x 252 x 118mm excluding spigot
Model DX180* DX180T* DX180H* DX200 DX200T CF20 CF20T *IPX4 rated
Ref 91181AW 91182AW 91183AW 91013AW 91014AW 91015AW 91016AW
· The unit shall be designed for flush or surface mounting in walls, ceilings or through glass (using the GMK kit) supplied complete with fixing clamps for flush mounting
Xpelair Premier LoVolt LVDX200 & LVCF20
The unit is to be supplied from the Xpelair Premier range by Applied Energy Products Ltd, Morley Way, Peterborough PE2 9JJ Tel. +44 (0)1733 456789 · A rectangular cut out section shall be provided to connect to Xpelair Profile 29 flatduct using Xpelair kit Ref. [. . . ] Provision shall be made for alternative condensate drain off points · Backward curved impeller
· The motors shall be UltraDC motors with maintenance free greased for life ball bearings · A supply lead shall be provided to facilitate wiring · Overall Dimensions W x H x D 740 x 600 x 540mm Weight :32kg
www. xpelair. co. uk
167
Xpelair Typical Specification
The unit is to be supplied from the Xpelair Xcell range by Applied Energy Products Ltd. Morley Way, Peterborough PE2 9JJ
· The MVHR unit shall be designed for installation in well insulated dwellings
· Access shall be provided to the stage 1 G3 filters. The unit shall have a choice of speeds to match the volume of the dwelling in order to provide half an air change per hour continuous ventilation including the choice of a boost speed if required. As a result the heat recovery cell shall be up to 91% efficient - certified by TZWL, depending on chosen speed. The fans shall be electronically balanced to provide equal extraction and air supply
Xpelair Typical Specification
Xpelair Xcell 600 Low Profile
The unit is to be supplied from the Xpelair Xcell range by Applied Energy Products Ltd. +44 (0)1733 456789 · The MVHR unit shall have a slimline insulated steel case and sealed access panel. The unit shall be suitable for ceiling or loft mounting in confined spaces using the integral mounting point detail provided · The heat recovery unit shall be up to 70% efficient depending on volume setting and be compatible with heat pump systems · The unit shall be fitted with double inlet fans for quiet operation and be set at a speed calculated on the volume/duty of the dwelling in accordance with Building Regulations Part F1. A remotely fitted single gang switch shall be provided with the unit. Heavy duty supply and exhaust filters shall be included in the unit · The condensate tray shall have an anti bacterial coating. The unit shall have 200mm spigots on the room side and discharge side · A further model shall be available fitted with a motorised summer Bypass feature · Dimensions H x W x L 250 x 750 x 1100mm (Excluding spigots)
Model Xcell 600 Xcell 600BP
Ref 92002AA 92003AA
Xpelair Profile 150
The components are to be supplied from the Xpelair Profile 150 range by Applied Energy Products Ltd. +44 (0)1733 456789
Roof Cowl Wall Cowl
91277AA 91278AA
· A selection of bends constructed of the
· Profile 150 ductwork shall be used in
Model 2. 5m straight duct 90º bend 45º bend 30º bend 15º bend Pushfit collar Snap Clamp Collar
Ref 91272AA 91273AA 91274AA 91275AA 91276AA 91279AA 91280AA
conjunction with Xflex ductwork and Profile 60 flat duct to provide the distribution system for Xcell MVHR units
· Ducting shall be manufactured in steam
same material shall be available. Performance shall have been proven by type testing in accordance with BS 848 Part 1 and FID performance determined to be: (m3/h) PX6 PX9 PX12 extract 246 790 1712 intake 458 1070
·
·
Xpelair RX6, RX9 & RX12
The unit is to be supplied from the Xpelair RX range by Applied Energy Products Ltd. +44 (0)1733 456789 · · The fan shall be suitable for roof mounting through clear and obscure glazing, polycarbonate sheeting, roof mounting plates and materials up to 25mm On non smooth glass surfaces a suitable sealant shall be applied to the outer gasket Performance shall have been proven by type testing in accordance with BS 848 Part 1 and FID performance determined to be: (m3/h) RX6(T) RX9 RX12 · extract 206 511 1100 intake 438 915 · A passive trickle vent option shall be incorporated into the inner grille shutter cassette to provide low level ventilation when the unit is not in use The shutter shall be operated by a silent electrothermal actuator It shall be possible to remove the inner grille and shutter cassette separately for cleaning An outer roof cowl with internal deflector shall be provided, this to be moulded in ABS with high gloss UV stabilised finish on RX9 and RX12 models Customer electrical connection shall be via an internal tamper-proof plug and socket on RX9 and RX12 models A concealed switch on the unit shall predetermine the mode of operation: intake only, or extract only or optional controller operation The unit shall be BEAB approved Overall internal projection shall be: RX6 RX9 RX12 112mm 117mm 161mm
·
Model RX6 RX9 RX12
Ref 90818AW 90424AW 90425AW
·
·
·
·
All models shall have totally enclosed AC motors with sealed for life bearings, with external rotor motors on RX9 / RX12, and safety thermal overload protection The high efficiency moulded axial bladed impeller shall be pre-balanced for optimum performance and ease of removal for cleaning Motor/impeller assembly shall be in a rigid ABS housing with high gloss finish and incorporate a finger guard
·
·
· ·
·
170
Xpelair WX6, WX9 & WX12
The unit is to be supplied from the Xpelair WX range by Applied Energy Products Ltd. +44 (0)1733 456789 · · · The fan shall be suitable for wall mounting Installation shall be mortar free and the product shall be supplied complete with wall liner Performance shall have been proven by type testing in accordance with BS 848 Part 1 and FID performance determined to be: (m3/h) WX6(T) WX9 WX12 · extract 246 783 1715 intake · 477 969 · · The shutter shall be operated by a silent electrothermal actuator It shall be possible to remove the inner grille and shutter cassette separately for cleaning An outer grille shall be provided, this to be moulded in Shadow Grey ABS with high gloss finish and incorporate weatherproof vanes On WX9 and WX12 models customer electrical connection shall be via an internal tamper-proof plug and socket On WX9 and WX12 models a concealed switch on the unit shall predetermine the mode of operation: intake only, or extract only or optional controller operation for speed control and reversibility The unit shall be BEAB approved Overall internal projection shall be: WX6 11mm WX9 / WX12 18mm
·
·
Model WX6 WX6T WX9 WX12
Ref 90822AW 90823AW 89996AW 90011AW
All models shall have totally enclosed AC motors with sealed for life bearings, with external rotor motors on WX9 / WX12, and safety thermal overload protection The high efficiency moulded axial bladed impeller shall be pre-balanced and designed for optimum performance and ease of removal for cleaning Motor/impeller assembly shall be in a rigid ABS housing with high gloss white finish and incorporate a finger guard A passive trickle vent option shall be incorporated into the inner grille shutter cassette to provide low level ventilation when the unit is not in use
·
· ·
·
·
Xpelair WXXL
The unit is to be supplied from the Xpelair WXXL range by Applied Energy Products Ltd. +44 (0)1733 456789 · · WXXL models shall have G. S. M. telescopic wall liner suitable for installation in solid and cavity walls from 275mm to 375mm The external rotor motor rated at IP44 shall be fitted with sealed for life maintenance free bearings On the inner wall face the fan shall be fitted with a white epoxy coated aluminium internal wall grille with removable core for easy cleaning. The fan assembly shall be separately guarded for additional safety The shutter shall be manufactured from aluminium housed behind a anodised aluminium external weather louvre · On intake models the shutter shall be electro-mechanically opened and be fitted with a washable prefilter The fan shall have a built in three speed control. A separate slimline three position and off selection switch shall be provided for remote wall mounting
·
Model Extract models WXXL350 WXXL400 WXXL450 Intake models WXXLS350 WXXLS400 WXXLS450
Ref 91301AA 91302AA 91303AA
·
·
91383AA 91384AA 91385AA
www. xpelair. co. uk
171
Xpelair Typical Specification
Xpelair Typical Specification
Xpelair ChefX
The unit is to be supplied from the Xpelair ChefX range by Applied Energy Products Ltd. +44 (0)1733 456789 · Professional quality extract canopy of robust construction designed for spot ventilation in food preparation and wash up areas. Designed for exhaust operation to the outside using rigid ductwork supplied by others The canopy housing shall be manufactured in stainless steel with G. S. M internal support Washable grease filters shall be provided The hood shall have an integral fan assembly with continuously rated motor and sealed for life beatings. The motor shall be IPX4 rated and be suitable for temperatures up to 65oC · · The motor shall be speed controllable using optional electronic controller or a five step voltage transformer. The tempo model shall be fitted with a built in speed controller and integral lighting Dimensions Tempo Presto Mezzo HxWxL 180 x 600 x 540 2350 x 1000 x 460 400 x 1000 x 1000
·
Model ChefX Tempo ChefX Presto ChefX Mezzo Controls for Presto/Mezzo Transformer
Ref 91309AA 91310AA 91311AA
· · ·
Performance @ 100pa duct resistance Tempo Presto Mezzo 400m3/h 2200m3/h 2800m3/h
91369AA
Xpelair Digitemp
The unit is to be supplied from the Xpelair Digitemp range by Applied Energy Products Ltd. +44 (0)1733 456789 · · The three speed unit shall be designed for surface mounting on walls at high or low level without the need for an external condenser Two airside wall tubes shall be provided for fitting through 155mm sloping core drilled holes through the external wall to the outside The maximum length of the tubes shall be 1000mm Two folding external grilles shall be supplied for fitting through the wall tubes from within the room All "cooling only" (WA210N & WA245N) units shall not require a condensate drain Control shall be from a full function hand held infrared controller with a range of 8m The unit refrigerant shall be factory sealed with no opening of the system or hose connections on site Refrigerant R410a shall be used having an Ozone Depletion Power Rating of `0' · · · · The unit shall be fitted with a pollen filter The unit shall be sound insulated and have a super quiet night time function The unit shall have a self-diagnostic system, which displays the condition of the unit using a series of LEDs Performance shall be as follows: model WA210N WA245N WHP210N WHP245N cooling kW 2. 1 2. 45 2. 1 2. 45 heating kW
Model Cooling WA210N WA245N Heating & cooling WHP210N WHP245N
Ref
·
·
91173AA 91174AA
·
91175AA 91154AA
· · ·
1. 9 2. 03
Overall dimensions: WxHxD 870 x 400 x 280mm Min. [. . . ] Insulation is to class F Impellers shall be high efficiency, low noise pressed steel sickle blade design · · Rotors and impellers are to be dynamically balanced to ISO 1940-1:1986 Grade G 6. 3 Customer connection shall be conveniently located in an IPX4 rated terminal box attached to the body of the fan Terminals shall be provided within the terminal box for connection to an external thermal overload protection device The fans shall be suitable for use in ambient temperatures ranging from 30°C to +60°C minimum and higher on selected models The fan shall be fully speed controllable using the appropriate speed controller or 5 step auto transformer (available as an ancillary) Must be suitable for 220-240V IPH 50Hz electrical supply
·
Model XSCS315-12 XSCS315-14 XSCS355-14 XSCS400-14 XSCS400-16 XSCS450-14 XSCS450-16 XSCS500-14 XSCS500-16 XSCS560-14 XSCS560-16 XSCS630-16
Ref 91570AA 91571AA 91573AA 91574AA 91575AA 91576AA 91577AA 91578AA 91579AA 91580AA 91581AA 91583AA
·
·
·
· ·
·
·
Xpelair Rapier XPMA
The unit is to be supplied from the Xpelair XPMA range by Applied Energy Products Ltd. +44 (0)1733 456789 · · The fan shall be suitable for reverse operation The fan plate shall be manufactured from a single steel pressing to ensure perfect form of the inlet bell mouth and uniformity of impeller tip clearance The fan body, impeller and motor housing shall be further protected from deterioration by coating with corrosion resistant powder coat finish The motor shall be IP44 and IP54 rated external rotor type, AC capacitor start and run and have sealed for life ball bearings. Terminals will be provided for connection to an external thermal/overload protection device Insulation is to be rated to class F Impellers shall be high efficiency, low noise pressed steel sickle blade design · Rotors and impellers are to be dynamically balanced to ISO 1940-1:1986 Grade G 6. 3 Customer connection shall be conveniently located in an IP54 rated terminal box located on the rear of the motor The fans shall be suitable for use in ambient temperatures ranging from -30°C to +60°C and higher on selected models All fans shall be supplied with an integral inlet guard to EN294 The fan shall be fully speed controllable using the appropriate speed controller or 5 step auto transformer (available as an ancillary) Must be suitable for 220-240V IPH 50Hz electrical supply
·
Model XPMA315-12 XPMA315-14 XPMA355-14 XPMA400-14 XPMA400-16 XPMA450-14 XPMA450-16 XPMA500-14 XPMA500-16 XPMA560-16 XPMA630-16 XPMA710-16
Ref 91540AA 91541AA 91543AA 91545AA 91546AA 91547AA 91548AA 91040AA 91549AA 91550AA 91050AA 91055AA
·
·
·
·
·
· ·
·
www. xpelair. co. uk
175
Xpelair Typical Specification
Xpelair Typical Specification
Xpelair Rapier XSCA
The unit is to be supplied from the Xpelair XSCA range by Applied Energy Products Ltd. +44 (0)1733 456789 · · The fan housing shall be manufactured from galvanised steel. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE APPLIED ENERGY XIL125T
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual APPLIED ENERGY XIL125T will begin.