User manual ARGUS SYSTEM TECHNOLOGY AST-400

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ARGUS SYSTEM TECHNOLOGY AST-400. We hope that this ARGUS SYSTEM TECHNOLOGY AST-400 user guide will be useful to you.

Lastmanuals help download the user guide ARGUS SYSTEM TECHNOLOGY AST-400.


Mode d'emploi ARGUS SYSTEM TECHNOLOGY AST-400
Download
Manual abstract: user guide ARGUS SYSTEM TECHNOLOGY AST-400

Detailed instructions for use are in the User's Guide.

[. . . ] 4Ch Real time / Triplex / Mux CCT716 DVR 4 Channel Stand Alone DVR USB Backup available CD-WRITER NETWORKABLE VGA MONITOR CONNECTION PTZ CONTROL User' Manual s VER 1. 2 The most stable and reliable real stand alone Digital Video Multiplex Recorder 4Ch Real time/Triplex/Mux - Stand Alone DVR Installation & Safeguards INSTALLATION & SAFEGUARDS All the safety and operating instructions should be read before the unit is operated. To prevent electric shock or other hazards, do not expose units to rain, moisture or dust. Place this unit in a well-ventilated place and do not place heat-generating objects on the unit. This unit should not be located in an area where it is likely to be subjected to vibration. Before You Start 1. [. . . ] To save the setting value and exit, click ` ESC' . Blocked Area (non-motion detection area) Non-Blocked Area (motion detection area) 25 4Ch Real time/Triplex/Mux 5) INTERVAL SETUP - Stand Alone DVR CHAP. 5 Set up See the switching time interval for SEQ or PIP function. ~99 sec. ) INTERVAL SETUP SEQUENCE SCREEN :Set the sequencing time SEQUENCE SCREEN interval in live full screen mode. PIP SCREEN EVENT UPDATE 01 SEC 01 SEC 600 SEC DEFAULT ESC PIP SCREEN : Set the sequencing time interval of PIP window. EVENT UPDATE : Set the minimum time interval of event to be listed on EVENT LIST. If EVENT UPDATE time is set at 5 sec, only events lasting longer than 5 s econds are listed. 6) ALARM SETUP Set type of alarm sensors connected to DVR unit. N. O represents Normally Open type and N. C Norm ally Close type. INPUT : Select NORMAL OPEN, NORMAL CLOSE, or DISABLE. DISABLE represents not to use alarm sensor connected to DVR. DURATION : Set the duration of alarm when an ALARM is activated. ~ 300 sec. ) ALRAM SETUP CHANNEL INPUT DURATION ALL-DEFAULT DEFAULT CH1 DISABLE 01 SEC ESC 7) PASSWORD SETUP Set user ID and Password. You can make up to an 8 digit number combination for a password by clicking number ` 0'~ ` 9'in password setup menu. To change password, you need to click ` USER PW'first to activate the menu. You must input current password and then input new password. And input again new password to confirm. PASSWORD SETUP USER ID USER PW NEW PW CONFIRM ADMIN ---------------------- 0 1 2 3 4 5 6 7 8 9 ESC ENTER Number selection for password Changing the user Password is recommended for security purposes. 26 4Ch Real time/Triplex/Mux - Stand Alone DVR CHAP. EXTERNAL DEVICE Set parameters of external devices connected to DVR like Ethernet, PTZ camera, Spot monitor etc. If you click ETERNAL DEVICE on the main menu, then you will see the window shown on the right. EXTERNAL DEVICE TCP/IP SETUP PAN/TILT SETUP SPOT SETUP ESC 1) TCP/IP SETUP TCP/IP SETUP TCP/IP function enables you to see live pictures and recorded pictures via internet. IP SETUP DDNS SETUP CONNECTION SETUP ESC (1) IP SETUP : IP SETUP Shows the network information assigned to the DVR unit. If the DHCP setup status is AUTOMATIC, you can set the IP port only and if the DHCP setup status is MANUAL, you must set all parameters. If IP port number is blocked, a network specialist' advice is needed. s MAC ADDRESS DHCP MODE 00-0A-A2-00-FD-63 MANUAL IP DETECT 50000 192. 168. 001. 160 192. 168. 001. 001 255. 255. 255. 000 DEFAULT ESC IP PORT IP ADDRESS GATEWAY SUBNET 27 4Ch Real time/Triplex/Mux 2) PAN/TILT SETUP PAN/TILT SETUP COMMAND SETUP SPEED SETUP ESC - Stand Alone DVR CHAP. 5 Set up COMMAND SETUP ß PTZ Camera setup ß PTZ Speed setup CHANNEL MODEL PTZ ID BAUDRATE CMD DELAY COMMAND LENGTH CODE 7 7 7 7 DEFAULT ESC 01 PELCO-D 000 2400 BPS 1 MSEC PAN/TILT STOP 16 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 ALL-DEFAULT ESC PAN/TILT SETUP PAN SPEED TILT SPEED ZOOM SPEED FOCUS SPEED DEFAULT 1) 2) 3) 4) 5) CHANNEL : Select channel MODEL : Select camera model (protocol type) per each channel PTZ ID : Select PTZ ID (per each channel) BAUDRATE : Select data transmission speed CMD DELAY : Select command delay time 3) SPOT SETUP SPOT SETUP SWITCH INTERVAL ALARM POP UP MOTION POP UP EVENT POP UP DURATION DEFAULT 03 SEC ON ON 05 SEC ESC (1) SWITCHING INTERVAL Channel switching time (01 sec. ~ 99 sec. ) (2) ALARM POP-UP When ALARM is detected, the image of channel connected with Alarm sensor pops up. [. . . ] Image Edit Status Window : Shows record time & date, Image size, Command status. 2. Edit Button : User can adjust colour tone of copied images using this button. - Contrast : a) make bright part of image brighter and dark part of image darker b) To reduce light and shade, lower contrast a little - Brightness a) make an image brighter b) make an image darker - Sharpness : give sharp-edge effect - Blur : make an image soft 3. Function button a) Save : User can save an image in JPEG format. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ARGUS SYSTEM TECHNOLOGY AST-400

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ARGUS SYSTEM TECHNOLOGY AST-400 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag