User manual ASUS AP1710-E1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ASUS AP1710-E1. We hope that this ASUS AP1710-E1 user guide will be useful to you.

Lastmanuals help download the user guide ASUS AP1710-E1.


Mode d'emploi ASUS AP1710-E1
Download

You may also download the following manuals related to this product:

   ASUS AP1710-E1 (7898 ko)

Manual abstract: user guide ASUS AP1710-E1

Detailed instructions for use are in the User's Guide.

[. . . ] AP1710-E1 Dual Intel® XeonTM Pedestal/5U Rackmount Server 800 MHz Front Side Bus E1779 First Edition V1 November 2004 Copyright © 2004 ASUSTeK COMPUTER INC. No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER INC. ASUS provides this manual "as is" without warranty of any kind, either express or implied, including but not limited to the implied warranties or conditions of merchantability or fitness for a particular purpose. In no event shall ASUS, its directors, officers, employees, or agents be liable for any indirect, special, incidental, or consequential damages (including damages for loss of profits, loss of business, loss of use or data, interruption of business and the like), even if ASUS has been advised of the possibility of such damages arising from any defect or error in this manual or product. [. . . ] Make sure that you disconnect all pre-connected cables so they do not get in the way when you install the second drive cage. To install an IDE drive cage: 1. Position the drive cage into the bay with the screw hole tab on top and facing out. 2. Carefully slide the drive cage toward the front panel until it fits in place. ASUS AP1710-E1 3-5 3. Make sure that the drive cage fits snugly to the bay as shown. The drive cage is properly installed when it is parallel to the front panel, and the screw hole matches the hole of the first drive cage. 4. Secure the drive cage with a screw. 3-6 Chapter 3: Installation options 3. 3 Upgrading to a dual or redundant power supply Perform this installation if you wish to upgrade your barebone server system from 600 W single power supply to 600 W dual or redundant power supply. Remove the single power supply following the instructions in the section "2. 10 Removable components. " Lay the system on its side on a flat surface, then remove the metal stopper screw under the power supply cage. Keep the screw for later use. 3. Locate and remove the metal stopper from inside the power supply cage. Keep the metal stopper for later use. 4. Insert the power supply cables and plugs to the power supply cage. ASUS AP1710-E1 3-7 5. Push the power supply halfway to the power supply cage, then attached the a metal bracket on each side of the power supply with two screws. 6. Push the power supply to the power supply cage. Make sure that the metal brackets and the chassis screw holes 7. Secure the power supply to the chassis with two screws on each metal bracket. 3-8 Chapter 3: Installation options 3. 4 Installing a power supply module Perform this installation if you wish to upgrade your barebone server system from 600 W dual to 600 W redundant power supply. Press down the rubber lever of the dummy module to unlock. 2. Use the module handle to pull the dummy module out from the power supply case. 3. Insert the power supply module to the empty bay with the power connector on top. ASUS AP1710-E1 3-9 4. Push the power supply module inside the bay until it is aligned with the other power supply modules. The picture shows the power supply module when installed. 3-10 Chapter 3: Installation options 3. 5 3. 5. 1 Mounting the system to a rack Removing the footpads or roller wheels Refer to section "2. 10. 7 Chassis roller wheels and footpads" for instructions on removing the footpads or roller wheels. 3. 5. 2 1. 4. Removing the top cover To remove the top cover: Remove the side cover. Refer to section "2. 1. 1 Removing the side cover" for instructions. Refer to section "2. 5. 1 Removing the front panel assembly" for instructions. Locate the lock tab underneath the top cover and press it outward to release the cover. Slide the top cover toward the front panel, then lift it up from the chassis. Lock tab of top cover (bottom view) 3. 5. 3 Attaching the rack rails Refer to the installation guide that came with the Rackmount Rail Kit for instructions on how to attach the rails and on the barebone server system and the corresponding rails on the industrial rack. ASUS AP1710-E1 3-11 3-12 Chapter 3: Installation options Chapter 4 This chapter gives information about the motherboard that comes with the server. This chapter includes the motherboard layout, jumper settings, and connector locations. ASUS AP1710-E1 Motherboard info 3-1 4. 1 Motherboard layout 26. 8cm (10. 5in) SSI12V1 PS/2KBMS T: Mouse KBPWR1 B: Keyboard NCLV-D SSIPWR1 REAR_FAN1 PSUSMB1 USB12 USBPW12 COM1 DDR DDR_B2 (64 bit, 184-pin module) FM_CPU1 DDR DDR_A2 (64 bit, 184-pin module) DDR DDR_B1 (64 bit, 184-pin module) CPU1 VGA DDR DDR_A1 (64 bit, 184-pin module) LAN1 LAN2 Gigabit LAN BCM5721 LAN_EN1 Gigabit LAN BCM5705E MCH E7320 CPU2 FM_CPU2 REAR_FAN2 CPU_FAN2 PCIX1 (64-bit PCI-X) LAN_EN2 SATA_EN1 FRNT_FAN1 FRNT_FAN2 PCIX2 (64-bit PCI-X) ATI RAGE XL VGA Controller PCIE3(x4 link) VGA_EN1 Adaptec AIC-8130 SATA2 PCI4 (32-bit 5V PCI) SB_PWR1 RECOVERY1 ICH 6300ESB SATA1 USB34 Intel Super I/O 8Mbit Flash BIOS CLRTC1 CR2032 3V Lithium Cell CMOS Power PCI5 (32-bit 5V PCI) BMCSOCKET1 BMCCONN1 BPSMB1 LPT1 COM2 SEC_IDE1 PRI_IDE1 FLOPPY1 HDLED1 AUX_PANEL1 USBPW34 8130 LED1 PANEL1 The Adaptec AIC-8130 RAID controller and RAID Serial ATA features are optional. These components are grayed out in the above motherboard layout. 4-2 Chapter 4: Motherboard information SATA_RAID1 SATA_RAID2 SATA_RAID3 SATA_RAID4 30. 5cm (12in) Intel mPGA 604 CPU_FAN1 mPGA 604 Layout contents Jumpers 1. Clear RTC RAM (CLRTC1) CPU fan pin selection (3-pin FM_CPU1, FM_CPU2) USB device wake-up (3-pin USBPW12, USBPW34) Keyboard power (3-pin KBPWR1) Gigabit LAN (BCM5721) controller setting (3-pin LAN_EN1) Gigabit LAN (BCM5705E) controller setting (3-pin LAN_EN2) SATA controller setting (3-pin SATA_EN1) 8130 LED setting (3-pin 8130LED1) VGA Graphics controller setting (3-pin VGA-EN1) Page 4-4 4-5 4-5 4-6 4-6 4-7 4-7 4-8 4-8 4-9 10. BIOS Recovery setting (3-pin RECOVERY1) Internal connectors 1. Floppy disk drive connector (34-1 pin FLOPPY) IDE connectors (40-1 pin PRI_IDE1, SEC_IDE1) Serial ATA connectors (7-pin SATA1, SATA2) Serial ATA RAID connectors (7-pin SATA_RAID1, SATA_RAID2, SATA_RAID3, SATA_RAID4) (Optional) Hard disk activity LED connector (2-pin HDLED1) CPU, Chassis, and Power Fan connectors (3-pin CPU_FAN1/2, REAR_FAN1/2, FRNT_FAN1/2) USB connector (10-1 pin USB34) Serial port connector (10-1 pin COM2) SSI power connectors (24-pin EATXPWR1, 8-pin ATX12V1) Page 4-10 4-11 4-12 4-13 4-13 4-14 4-15 4-15 4-16 4-17 4-17 4-18 4-18 4-19 4-19 4-19 4-19 4-19 4-19 4-19 4-19 4-20 4-20 4-20 4-20 4-20 4-20 10. Backplane SMBus connector (6-1 pin BPSMB1) 11. Power Supply SMBus connector (6-1 pin PSUSMB1) 12. Parallel port connector (26-1 pin LPT1) 13. [. . . ] Select one of the options from this menu or <F10> from the legend bar to exit. Exit & Save Changes Once you are finished making your selections, choose this option from the Exit menu to ensure the values you selected are saved to the CMOS RAM. An onboard backup battery sustains the CMOS RAM so it stays on even when the computer is turned off. When you select this option, a confirmation window appears. Select Y e s to save the changes and exit. If you attempt to exit the Setup program without saving your changes, the program prompts you with a message asking if you want to save your changes before exiting. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ASUS AP1710-E1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ASUS AP1710-E1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag