User manual ATIKA ASP 10 N-400

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ATIKA ASP 10 N-400. We hope that this ATIKA ASP 10 N-400 user guide will be useful to you.

Lastmanuals help download the user guide ATIKA ASP 10 N-400.


Mode d'emploi ATIKA ASP 10 N-400
Download
Manual abstract: user guide ATIKA ASP 10 N-400

Detailed instructions for use are in the User's Guide.

[. . . ] Under our sole responsibility, that the product Log splitter ASP 10 N ­ 400 (Serial number: see last page) is conform with the above mentioned EC directive as well as with the provisions of the guideline below: 2004/108/EC. Splitting blade Control arm-left Table plate Motor On / Off-switch Oil tank cap with dip stick Table Wheel Locking lever Control arm-right Control handle Clamping claw left Retaining pin Handle Stroke adjustment rod Holding screw Splitting cross Hydraulic valve Hydraulic oil (1 litre) Safety label 1 Safety label 2 Safety label 3 Safety label 4 Clamping claw right Star grip screw Base After unpacking, check the contents of the box That it is complete Check for possible transport damage Report any damage or missing items to your dealer, supplier or the manufacturer immediately. Complaints made at a later date will not be acknowledged. 1 ready mounted machine unit 1 table plate 1 axle 1 bag of accessories 1 control arm, right 1 control arm, left 1 operating manual 2 wheels Mount control arms Insert control arms and insert pipe in recess of cross connection. [. . . ] Do not use the cable for purposes for which it is not meant. Protect the cable against heat, oil and sharp edges. Do not use the cable to pull the plug from the socket. Regularly check the extension cables and replace them if they are damaged. Do not use any defective connection cables. When working outdoors, only use extension cables especially approved and appropriately labelled for outdoor use. Do not set up any provisional electrical connections. never bypass protective devices or deactivate them. The electrical connection or repairs to electrical parts of the machine must be carried out by a certified electrician or one of our customer service points. Local regulations ­ especially regarding protective measures ­ must be observed. Repairs to other parts of the machine must be carried out by the manufacturer or one of his customer service points. Accidents can arise for the user through the use of other spare parts. The manufacturer is not liable for any damage or injury resulting from such action. Ensure that the working area meets the following conditions: - no danger of slipping - level - free of obstacles - sufficiently well lit Do not operate the machine in the direct vicinity of gas or petrol pipes or containers, or any other easily inflammable materials. Before using the log splitter, make sure each time that - there are no faulty connections (tears, cuts, etc. Do not use defective power supply cables. There are no damages at the machine all screws are tight check the hydraulic system for any possible leaks the oil level The transport closure must be replaced by the oil dipstick before start up the machine. Move the splitting blade right down every time before the machine is transported. to transport the machine , grasp the handle and tilt the log splitter slightly towards you. The log splitter can be easily transported in this position. Make sure that the oil tank cap is securely tightened to prevent oil from leaking during transport. Oil dipstick If the hydraulic system is not vented, the trapped air will damage the seals and cause permanent damage to the log splitter. [. . . ] Now remove the dipstick again and read off the oil level. Check the oil seal and replace it if it is damaged in any way. Dispose of the old oil properly (local oil disposal point). The old oil must not be poured into the ground or drainage system, or mixed with other waste. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ATIKA ASP 10 N-400

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ATIKA ASP 10 N-400 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag