User manual ATIKA COMPACT 100 BROCHURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ATIKA COMPACT 100. We hope that this ATIKA COMPACT 100 user guide will be useful to you.

Lastmanuals help download the user guide ATIKA COMPACT 100.


Mode d'emploi ATIKA COMPACT 100
Download
Manual abstract: user guide ATIKA COMPACT 100BROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] Pass the safety instructions on to all persons who work with the machine. Keep these safety instructions in a safe place. Make yourself familiar with the equipment before using it, by Correct use Acceptable risks Safety instructions Start-up - switching on and off Mixing Transport Storage Cleaning Maintenance Repair Guarantee Malfunktion Circuit diagram Technical data Spare parts Page 5 Page 5 Page 5 Page 6 Page 6 Page 6 Page 6 Page 6 Page 6 Page 7 Page 7 Page 7 Page 7 Page 30 Page 31 Page 32/33 Do not use the device when you are tired or under the influence of drugs, alcohol or medicaments. One moment of carelessness when using the device can result in serious injuries. [. . . ] Never bridge over protective devices or put them out of operation. Only connect with residual current circuit breaker (30 mA). Repeat points 3 and 4 until required mixture ratio has been achieved. Have a professional advise you regarding the composition and quality of the material being mixed. Prepared (commercially available) mixture production: Observe mixing ratio and details given by manufacturer on packaging. There is a sack opener on the safety grid which is used to tear open the packed mixture and filling the drum. Emptying the mixing drum: The drum is emptied through an opening in the base which is opened by actuating a lever. A licensed professional electrician must make all electrical connections and repairs, and observe local regulations in doing so, especially those regarding protective measures. The manufacturer or a company designated by the manufacturer must attend to the repair of all electrical parts on the machine. Keep the machine from sinking into the ground or floor. adhere to accident prevention regulations (danger of tipping). When setting up the machine, make sure that the mixing drum can be emptied without obstruction. The mixer should be cleaned thoroughly before long storage periods and moving parts treated with an environmentally-friendly spray oil. This lengthens the useful life of a mixer and ensures smooth operation of the device. Switching on and off Be sure that - all protective devices are on the mixer and properly mounted. - all safety instructions are adhered to. In the event of a power failure, the machine will switch off automatically. Additional safety instructions Pull plug each time before cleaning. Switch off machine and pull plug if you have to touch the machine (with hand, brush, scraper, rag, etc. Protective devices removed for cleaning must be properly remounted before starting the machine. Do not spray the motor and switch directly with a water jet. Remove agitator head to clean ( Before taking a break and after finishing work, clean the mixer inside and out. [. . . ] Malfunction Motor does not start up Possible cause No mains voltage The motor does not switch off when safety grid is open Machine starts up, but becomes blocked at low load and may switch off automatically Defective cable or plug Motor overloaded Temperature monitor activated Defective switch or cable in switch is not connected Safety grid is not closed Mixing apparatus blocked Too much mixture in drum Defective condenser Safety shutdown is not triggered Extension lead is too long or its crosssection is too small Socket is too far from mains connection and the connecting wire's cross section is too small Remedy Check fuse protection Have checked or replaced (electrician) Allow motor to cool down Check switch and/or replace Close safety grid Switch off machine, pull out mains plug and clean drum Actuate switch several times unsuccessful?Empty drum Send machine to manufacturer or a company designated by the manufacturer for repairs Check safety shutdown and/or re-place Extension lead must be at least 1. 5 mm² for a maximum length of 25 m; the cross-section of longer cables must be at least 2. Se till att det inte finns någon risk att snubbla på uppställningsplatsen och på området däromkring. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ATIKA COMPACT 100

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ATIKA COMPACT 100 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag