If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AUSTRALIAN MONITOR ACM120. We hope that this AUSTRALIAN MONITOR ACM120 user guide will be useful to you.
Lastmanuals help download the user guide AUSTRALIAN MONITOR ACM120.
Manual abstract: user guide AUSTRALIAN MONITOR ACM120BROCHURE
Detailed instructions for use are in the User's Guide.
[. . . ] Description
The ACM120 is a 4 channel, 120 watt mixer amplifier suitable for rack or desk mounting. The amplifier is a self contained compact unit of solid steel construction.
Inputs
120W, 4 Channel Mixer Amplifier
ACM120
The ACM120 has four universal input channels with separate level controls. [. . . ] Tones include Bell, Pre-Announce Chime, Alert Tone (AS2220. 1) and Evacuate Tone (AS2220. 1). Any of these tones may be activated from a simple contact closure connected to the rear panel of the amplifier. A Pre-announce defeat switch is located on the front panel.
Muting
VOX muting is standard on the ACM120. A mic or line signal on channels 1 or 2 will mute channels 3 and 4. The muting function can be disabled via an internal link.
Phantom Power
Phantom Power (18V DC) is available from all mic inputs. A rear panel phantom power on/off switch is also provided.
Protection
Internal current limiting protects the amplifier from both overload and overdrive conditions. Australian Monitor Installation Series amplifiers feature a protection network that provides greater stability and performance. Our amplifiers are recognised worldwide for their reliability and this is due to the extensive levels of current limiting which protect the amplifiers from both overload and overdrive conditions.
Power Output Maximum Load Power Bandwidth Frequency Response Total Harmonic Distortion Signal To Noise Ratio Tone Controls Inputs
120 Watts RMS 80 Ohms @ 100 Volts 60Hz - 15kHz < 0. 5% THD 60Hz - 15kHz (± 3dB) 0. 5% @ 1kHz rated power -74dB with all controls at their centre position Bass @ 100Hz: Boost +12dB Cut -12dB; Treble @ 10kHz: Boost +9dB Cut -9dB Four mic/aux universal inputs with XLR female mic sockets and dual RCA aux sockets
Input Sensitivity Outputs
Mics: 1mV @ 200 Ohms; Aux 1-3: 75mV @ 47K Ohms; Aux 4: 300mV @ 47K Ohms
Speaker: 100, 70 Volts, 4 & 8 Ohms; Tape: 350mV @ 10K Ohms; Line: Balanced 700mV 18 Volts DC on all Mic inputs (rear panel on/off switch) Speaker zone selector, switches 100V line output to 6 separate zones. An "all call" switch overrides all zones.
Phantom Power Speaker Zone Selection
Controls
4 input channel gain controls, 1 Bass control, 1 Treble control, 1 Master gain control, 6 Speaker zone selector, 1 Speaker "all call" selector, Pre-announce defeat switch, Phantom Power switch (on rear panel)
Indicators Power Source Power Consumption Protection Dimensions/Weight Rack Mounting Tone Generators
Power "on" LED AC 230/240V - 60Hz, 110V - 50Hz (special) 3 pin IEC connector 250 Watts Soft limiter for overload and overdrive protection, plus AC and DC fuses 88mm H x 480mm W x 330mm D (Chassis dimensions only). 12kg Standard Built-in four tone generator module. [. . . ] The amplifier must be capable of delivering 120 watts RMS into an 80 inductive ohm load, with less than 0. 5% distortion measured at 1kHz and with system hum and noise less than -74dB. The amplifier shall be an Australian Monitor Installation Series model ACM120.
Engineered and Distributed By AUDIO TELEX COMMUNICATIONS PTY LTD (ABN 78 001 345 482), 149 Beaconsfield Street, Silverwater, Sydney, NSW, 2128 Australia
NSW Tel: (02) 9647 1411 Fax: (02) 9648 3698 VIC Tel: (03) 9890 7477 Fax: (03) 9890 7977 QLD Tel: (07) 3852 1312 Fax: (07) 3252 1237 WA Tel: (08) 9228 4222 Fax: (08) 9228 4233 TAS Tel: (03) 6228 6373 Fax: (03) 6278 1063 SA Tel: (08) 8352 4444 Fax: (08) 8352 4488 Export Enquiries: export@audiotelex. com. au Website: www. australianmonitor. com. au [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE AUSTRALIAN MONITOR ACM120
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.