User manual AUSTRALIAN MONITOR AM1600

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AUSTRALIAN MONITOR AM1600. We hope that this AUSTRALIAN MONITOR AM1600 user guide will be useful to you.

Lastmanuals help download the user guide AUSTRALIAN MONITOR AM1600.


Mode d'emploi AUSTRALIAN MONITOR AM1600
Download

You may also download the following manuals related to this product:

   AUSTRALIAN MONITOR AM1600 BROCHURE (141 ko)

Manual abstract: user guide AUSTRALIAN MONITOR AM1600

Detailed instructions for use are in the User's Guide.

[. . . ] AM1600 Operation Manual IMPORTANT! Please read carefully. This operation manual contains important information regarding safety precautions, installation, performance, operation and maintenance of your AM1600 power amplifier. You should familiarize yourself with the contents of this manual before operating your amplifier. Safety Precautions and Labelling The rear panel of the unit has a number of markings and internationally recognized symbols related to the hazards and precautions that should be taken when operating MAINS connected equipment. The presence of a LIGHTNING FLASH with an arrowhead contained within the boundaries of an equilateral triangle is intended to alert the user that dangerous uninsulated voltages may exist within the unit's enclosure. These voltages may be of a sufficient magnitude as to constitute the risk of an electrical shock. [. . . ] When you power up your amplifier, your amplifier goes through an establishment period before it will accept signal. The Inrush Current Suppression (ICS) circuit is in operation for the first 0. 5 seconds. This limits the mains current to prevent "nuisance tripping" of circuit breakers. During this period the THERMAL LED will flash red whilst the mains voltage gradually charges up the power supply. You will then hear a relay "click", indicating mains is now directly applied to the amplifier. While the ICS circuit operates there is also a 30dB mute on the signal input. After two seconds this mute will release, allowing any applied signal to pass unattenuated. When switching the amplifier off, wait a couple of seconds before switching the unit on again. This allows the ICS circuit to reset. Level Matching The normal operating position for the attenuator is the "0 dB" position (fully clockwise, no attenuation). In this position the amplifier operates at full gain. Turning the attenuator back (anticlockwise) reduces the input sensitivity by the amount marked on the attenuator scale (dial). NOTE: If full power output is required you should operate your amplifier with the front panel attenuator above the -15dB position, otherwise clipping of the input circuitry and its resultant distortion will occur before full output power is achieved. Very Important Due to the high power ability of the AM1600 you need to be aware that certain precautions need to be followed to ensure longevity of your amplifier: Sensitivity Your amplifier is a linear device operating with a fixed input to output voltage gain (less attenuation). The maximum output voltage swing is determined by the applied mains voltage, load, load type and the duty cycle of the applied signal. The voltage gain factor of your amplifier is: 62. 0 times or 35. 8dB. The input sensitivity for your amplifier when the attenuator is at the "0" dB attenuation position (fully clockwise) is nominally: +2. 2dBu (1. 00volts in) for rated power into a 8 ohm load. +1. 5dBu (0. 92 volt in) for rated power into a 4 ohm load. - Never turn your amplifier on unless all connections (inputs and speakers) have been made! - Never plug in a signal lead after the amplifier has been turned on!- Never drive the output into clipping if the load is open circuit or there is no speaker load connected! Powering Up REMEMBER The amplifier should be the last piece of equipment that you turn on and the first piece of equipment that you turn off. We recommend turning the attenuators on your 14 Operation Each channel of your amplifier has a nominal balanced input impedance of 18k Ohms (@1kHz) and should not present a difficult load for any signal source. the equipment feeding the amplifier) should have an output impedance of 600 Ohms or lower to avoid unwanted high frequency loss in the cabling. Input overload occurs at +20. 5dBu (8. 25 volts). See the specification section for more detailed information. produces a voltage drop due to the wire's resistance. [. . . ] Only ever replace with the same type fuse and current rating. When checking for a failed fuse, do not rely on visual inspection alone. You should use an ohmmeter to check continuity. NOTE: Make sure the unit is off and is unplugged from the mains and give the main filter capacitors time to discharge before replacing fuses. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AUSTRALIAN MONITOR AM1600

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AUSTRALIAN MONITOR AM1600 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag