User manual AUSTRALIAN MONITOR AMIS250

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual AUSTRALIAN MONITOR AMIS250. We hope that this AUSTRALIAN MONITOR AMIS250 user guide will be useful to you.

Lastmanuals help download the user guide AUSTRALIAN MONITOR AMIS250.


Mode d'emploi AUSTRALIAN MONITOR AMIS250
Download

You may also download the following manuals related to this product:

   AUSTRALIAN MONITOR AMIS250 BROCHURE (364 ko)

Manual abstract: user guide AUSTRALIAN MONITOR AMIS250

Detailed instructions for use are in the User's Guide.

[. . . ] Adjusting the mid control in a counter-clockwise direction will provide up to -12 dB of mid cut @ 600 Hz. Treble Control Setting this control in the centre position will give an overall flat treble response. Adjusting the treble control in a clockwise direction will provide up to 9 dB of treble boost @ 10kHz. Adjusting the treble control in a counter-clockwise direction will provide up to -9 dB of treble cut @ 10 kHz. Master Output Control The Master level pot controls the overall output level of the amplifier depending on the levels set for the individual input channels as detailed above. Start with the control set to level 0 and turn clockwise until the desired output level of the amplifier is reached. Power Switch This switch controls the switching of AC power to the amplifier. [. . . ] Reading from left to right across the rear panel, the connection are for microphone inputs 6, 5, 4, 3, 2, & 1 respectively. Line Inputs Line inputs 1, 2, 3, 4, & 5 have an input sensitivity of 150mV @ 100K ohms. Input 6 has an input sensitivity of 300mV @ 220K ohms making it suitable for high level inputs such as a CD player. Reading from left to right across the rear panel, the connections are for inputs 6, 5, 4, 3, 2, & 1 respectively. Other Features Tone Generator Four separate tones are available from the in-built tone generator board. All four tones can be activated individually via a contact closure connected to the screw terminals on the rear of the amplifier. To activate the bell chime for example, just run a pair of wires from the Tone generator common and the Bell terminal to an external switch. Activating the switch, or closing the pair of wires, will activate the bell. When any tone is activated, all inputs (except for inputs one and two) will automatically mute. To adjust the level of the tone generator, disconnect the power lead, remove the amplifier lid and locate the pot labeled R6. (located behind the Bass adjustment pot). This pot adjusts the level for all 4 tones. Tones available on the AMIS250 include: Evacuation Tone Alert Tone Bell Tone Pre-Announce Chime Muting A VOX muting card is installed in the AMIS250. This feature provides automatic muting of some channels when others are active. It is normally used so that a paging microphone can have priority (by muting) over background music. VOX muting is available from channels 1 and 2 meaning that any signal on channels 1 and 2 (mic or line) will mute channels 3, 4, 5 & 6. The muted channels will automatically ramp back up to normal volume when the signal on channels 1 and/or 2 is no longer active. The amplifier ships with the VOX muting function enabled. To disable the VOX muting, disconnect the mains power lead and remove the lid of the amplifier. Looking down from the front of the amplifier, a three position jumper (labeled JP2) is located just to the left and behind the level pot for channel 1. To disable VOX muting, move the jumper to the middle and left pins. (The factory setting is with VOX enabled with the jumper on the middle and right pins). 600 Ohm Telephone Input The 600 ohm transformer balanced Telephone Input is paralleled with input 2. If telephone paging is required the XLR & dual RCA inputs should not be used as these inputs will be summed with the Telephone Input into channel 2. The front panel level control will set the gain for the Telephone Input. Insert Point The AMIS250 includes an Insert Point to allow for connection of signal processors such as equalisers, compressors or Feedback Exterminators. [. . . ] Never connect a "hot" (red) output to ground or to another "hot" (red) output!The power cord of equipment should be unplugged from the outlet when left unused for a long period of time. Service Information Equipment should be serviced by qualified service personnel when: A. The power supply cord or the plug has been damaged. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE AUSTRALIAN MONITOR AMIS250

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual AUSTRALIAN MONITOR AMIS250 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag