[. . . ] AXIS 207/207W Network Camera User's Manual
About this Document
This manual is intended for administrators and users of the AXIS 207/207W Network Camera, and is applicable for software release 4. 30 and later. It includes instructions for using and managing the AXIS 207/207W on your network. Previous experience of networking will be of use when using this product. Some knowledge of UNIX or Linux-based systems may also be beneficial, for developing shell scripts and applications. [. . . ] Configuration Log Level for Log Files - from the drop-down list, select the level of information to be added to the Log file Log Level for Email - from the drop-down list, select the level of information to send as email and enter the destination email address.
36 AXIS 207/207W - System Options
Resetting to the Factory Default Settings
To reset the camera to the original factory default settings, go to the System Options > Maintenance web page (as described in Maintenance, on page 34) or use the Control button on the underside of the camera (see page 7) as described below: Using the Control Button To reset the camera to the factory default settings using the Control Button: 1. Press and hold the Control button while reconnecting the power. Keep the Control button pressed until the Status Indicator color changes to amber (this may take up to 15 seconds). When the Status Indicator changes to Green (which may take up to 1 minute), the process is complete and the camera has been reset. The unit will now have the default IP address 192. 168. 0. 90
Advanced
Scripting is an advanced function that provides the possibility to customize and use scripts. Improper use may cause unexpected behavior or even cause loss of contact with the unit. If a script does cause problems, reset the unit to its factory default settings. A backup file may be of use to return the unit to its latest configuration. Axis strongly recommends that you do not use this function unless you fully understand the consequences. Note that Axis support does not provide assistance for problems with customized scripts. For more information, please visit the Developer pages at www. axis. com/developer Plain Config - this function is for the advanced user with experience of Axis network camera configuration. All parameters can be set and modified from this page. Help is available from the standard help pages.
AXIS 207/207W - The I/O Terminal Connector
37
The I/O Terminal Connector
Pinout and Interface
The 4-pin I/O terminal connector provides the interface to: · 1 transistor output · 1 digital input · auxiliary power and GND The terminal connector is used in applications for e. g. motion detection, event triggering, time lapse recording, alarm notification via email, etc. If the pushbutton is pressed, the state changes and the input becomes active (shown under Event Configuration > Port Status). an alarm device that can be activated by Output buttons on the Live View page, or by an Event Type. The output will show as active (Event Configuration > Port Status) if the alarm device is activated.
Function Transistor Output Pin 4 Description With a maximum load of 100mA and a maximum voltage of 24V DC, this output has an open-collector NPN transistor with the emitter connected to the GND pin. If used with an external relay, a diode must be connected in parallel with the load, for protection against voltage transients. Connect to GND to activate, or leave floating (or unconnected) to deactivate. Pinouts The I/O terminal pins on the AXIS 207 and AXIS 207W are numbered as shown below. AXIS 207
4 1
Digital Input GND Auxiliary DC Power Input
3 1 (AXIS 207W) 2 (AXIS 207) 1 (AXIS 207) 2 (AXIS 207W)
AXIS 207W
1 4
5VDC/min 2. 5W (AXIS 207) 5VDC/min 3. 5W (AXIS 207W) Electrically connected in parallel with the connector for the PS-L/PS-H power adapter, this pin provides an auxiliary connector for mains power to the unit. This pin can also be used to power auxiliary equipment, max 50mA.
38 AXIS 207/207W - The I/O Terminal Connector
Connect input/output devices to the camera as follows: 1. [. . . ] VPN (Virtual Private Network) - This creates a secure "tunnel" between the points within the VPN. Only devices with the correct "key" will be able to work within the VPN. The VPN network can be within a company LAN (Local Area Network), but different sites can also be connected over the Internet in a secure way. One common use for VPN is for connecting a remote computer to the corporate network, via e. g. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE AXIS 207W
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.