[. . . ] Electric Dryer Installation Instructions
PRODUCT MODEL NUMBERS WED94HEX, WED95HEX, WED97HEX, WEDXXHEX
Electrical: This dryer requires a 3 or 4 wire, single phase, 120/240 volt, 60 Hz. , AC only electrical supply (or 3 or 4 wire, 120/208 volt electrical supply, if specified on the serial/rating plate) on a separate 30-amp circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended. [. . . ] Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust. NOTE: Most installations require a minimum of 5" (127 mm) clearance behind dryer for exhaust vent with elbow. See "Venting Requirements. "
3/4"* (18 mm)
OVERALL DIMENSIONS
Dryer dimensions Front view:
27" (686 mm)
Side view:
507/8" (1292 mm) 305/8" (728 mm)
381/8" (968 mm)
Left or right side exhaust
3 /4"* (18 mm)
Back view:
61/2" (165 mm)
297/8"* (759 mm) 31/2"* (89 mm)
A
B
A. Angled hood (acceptable)
C
61/8"* (156 mm) (365 mm) 143/8"
3 /4"* (18 mm)
* Approximate measurement
The Vent system chart provides venting requirements that will help achieve best drying performance. NOTE: Side and bottom exhaust installation have a 90° turn inside the dryer. To determine maximum exhaust length, add a 90° turn to the total number of elbows when referemcing the chart.
Closet installation (dryer only):
Vent system chart
Number of 90° elbows Type of vent Rigid metal Rigid metal Rigid metal Rigid metal Rigid metal Box/louvered hoods 64 ft. (6. 4 m)
5" (127 mm)
18" min. (457 mm)
3" (76 mm)
48 in. 2 min. (310 cm2)
0 1 2 3 4
3" (76 mm) 1" (25 mm)
24 in. (155 cm2)
2
For closet installation, with a door, the minimum ventilation openings in the top and bottom of the door are required. [. . . ] For complete details, see Installation Instructions packed with product. Specifications subject to change without notice.
Ref. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BAUKNECHT WED94HEX
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BAUKNECHT WED94HEX will begin.