Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BEGLEC BRITEQ PD-32A. We hope that this BEGLEC BRITEQ PD-32A user guide will be useful to you.
Lastmanuals help download the user guide BEGLEC BRITEQ PD-32A.
Detailed instructions for use are in the User's Guide.
[. . . ] Accurate digital 3-digit voltmeters per phase Accurate digital 3-digit ampere meters per phase Two models are available: PD-32A Two C16 (16A - 1P+N) automatic circuit breakers per phase 1, 5m long mains input cable (3x 32A, 5wire), equipped with CEE (3P+N+E) 32A inlet plug CEE (3P+N+E) outlet socket (3x 32A, 5wire) for bypass 6x earthed 16A mains outlet sockets on the back panel (2 sockets per phase), 3 different models available: PD-32A/FR: French/Belgian 16A blue mains sockets PD-32A/GE: German 16A blue schukos (CEE 7/4) PD-32A/SA: South African 16A blue mains sockets PD-63A C32 (32A - 3P) automatic circuit breaker per output 1, 5m long mains input cable (3x 63A, 5wire), equipped with CEE (3P+N+E) 63A inlet plug 4x CEE (3P+N+E) 32A outlet sockets (3x 32A, 5wire) Extremely robust 19"/3U metal housing The lightning flash with arrowhead symbol within the equilateral triangle is intended to alert the use or the presence of un-insulated "dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock. The exclamation point within the equilateral triangle is intended to alert the user to the presence of important operation and maintenance (servicing) instructions in the literature accompanying this appliance. This symbol means: indoor use only This symbol means: Read instructions This symbol means: Safety Class I appliance The device is suitable for mounting on standard flammable surfaces. Standard flammable surfaces include building materials such as wood and wood-based materials more than 2mm thick. [. . . ] Apart from the mains fuse there are no user serviceable parts inside. never repair a fuse or bypass the fuse holder. Always replace a damaged fuse with a fuse of the same type and electrical specifications!In the event of serious operating problems, stop using the appliance and contact your dealer immediately. Please use the original packing when the device is to be transported. Due to safety reasons it is prohibited to make unauthorized modifications to the unit. User manual Some important instructions: Before you start using this unit, please check if there's no transportation damage. Should there be any, do not use the device and consult your dealer first. Important: This device left our factory in perfect condition and well packaged. It is absolutely necessary for the user to strictly follow the safety instructions and warnings in this user manual. Any damage caused by mishandling is not subject to warranty. The dealer will not accept responsibility for any resulting defects or problems caused by disregarding this user manual. Keep this booklet in a safe place for future consultation. If you sell the fixture, be sure to add this user manual. To protect the environment, please try to recycle the packing material as much as possible. RESIDUAL CURRENT CIRCUIT BREAKER: this is a vital security device of the power distributor!When someone accidentally touches one of the mains conductors, a current leak through the body of this person could result in a lethal (deadly) shock. As soon as such current leakage in the installation is detected, the power distributor outputs will be disconnected. the maximum allowable current leakage is set to 30mA. Under normal working conditions the lever on the right should be in upward position. Important: the functions of this device should be tested every 30days by pushing the test button on top: as a result the outputs should be immediately disconnected from the mains. INDIVIDUAL CIRCUIT BREAKERS: each of the 3 phases is secured by two C16 automatic circuit breakers. [. . . ] 360Watt, each 16A output socket support maximum 3. PD-32A Power Input: Maximum overall power: Maximum power per phase: Maximum power per output: Protection class: Max. 680Watt (16A) class I (only to be connected to class I outlets) 30mA 2x C16 (In=16A, instantaneous tripping current = 5x In) 5x 6mm² (H07RN-F 5G6) 32A-wires: 10AWG (5, 2mm²) 16A-wires: 14AWG (2, 1mm²) see drawings 7, 4 kg During inspection the following points should be checked: All screws used for installing the device and any of its parts should be tightly fastened and may not be corroded. Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any deformation. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BEGLEC BRITEQ PD-32A
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BEGLEC BRITEQ PD-32A will begin.