If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BEGLEC LED MEGA BEAM. We hope that this BEGLEC LED MEGA BEAM user guide will be useful to you.
Lastmanuals help download the user guide BEGLEC LED MEGA BEAM.
Manual abstract: user guide BEGLEC LED MEGA BEAMV1.0
Detailed instructions for use are in the User's Guide.
[. . . ] 3. 4--ACTIVATING AUTO PROGRAMS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10. 3. 5--RUN MODE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3. 6--DMX512 SETTINGS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11. 3. 7--PERSONALITY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11. [. . . ] The earth wire must always be connected to the ground. Do not touch the power cables if your hands are wet.
ATTENTION
This product left the place of manufacture in perfect condition. In order to maintain this condition and for safe operation, the user must always follow the instructions and safety warnings described in this user manual. Avoid shaking or strong impacts to any part of the equipment. Make sure that all parts of the equipment are kept clean and free of dust. Always make sure that the power connections are connected correct and secure. If there is any malfunction of the equipment, contact your distributor immediately. When transferring the product, it is advisable to use the original packaging in which the product left the factory. Shields, lenses or ultraviolet screens shall be changed if they have become damaged to such an extent that their effectiveness is impaired. The lamp (LED) shall be changed if it has become damaged or thermally deformed.
1 PRODUCT(GENERAL)
4
2008. 8. 13
2
2. 1
INSTALLATION
MOUNTING
HANGING
The fixture can be mounted in a hanging position using the supporting bracket. The bracket should be secured to the mounting truss or structure using a standard mounting clamp. Please note that when hanging the unit a safety cable should also be used.
UPRIGHT
The fixture can be mounted in an upright or sitting position using the supporting brackets.
The LED MODULE can be mounted at any angle and in any position. It is possible to further adjust the angle of the LED MODULE using the two adjustment knobs located on the side of the fixture.
2. 2
POWER CONNECTIONS
@ 220V: 10 units may be connected in series @120V: 5 units may be connected in series Note: 1. As this fixture's DMX signal cable connection is Parallel connection, so if over 32 units to be connected, then a DMX signal amplifier is needed. If the signal cable is over 60m between the DMX512 controller and fixture or beween two fixtures, then a DMX signal amplifier is needed as well.
2 INSTALLATION
5
2008. 8. 13
2. 3
SETTING UP WITH A DMX512 CONTROLLER
2. 3-1 DMX512 ADDRESSING WITHOUT ID ADDRESSING (STAG MODE)
Connect the DMX512 controller to the units in series. Each unit has 11 DMX channels so the DMX Addresses should increase by increments of 11 (e. g. 1, 12, 23, 34. . . ) The ID address has not been set so therefore when using the controller CH11 must be inactive ( CH11=0 ). It is also possible to deactivate ID address selecting ID OFF from the Settings menu. on the fixture Each DMX Address may be used as many times as required. Any DMX address in the range from 001 to 512 may be used.
Example:
DMX Addr. 1 DMX Addr. 12 DMX Addr. 23
DMX512 CONTROLLER
The figure above shows a simple DMX512 layout with the starting address of the first unit set at 1, with the second set at 12 and so on. . . (Note that when used in this way, the CH11 ID function must be inactive (CH11=0))
2. 3-2 DMX512 ADDRESSING WITH ID ADDRESS (STAG MODE)
Connect the DMX512 controller to the units in series Each unit has 11 DMX channels so the DMX Addresses should increase by increments of 11 (e. g. 1, 12, 23, 34. . . ) Each DMX Address may be used as many times as required. [. . . ] Each independent DMX address may have upto 66 independent ID addresses. An ID address of 0 will activate all ID address locations.
AUTO
CH8 selects the preset AUTO programs AT. 01-AT. 10 or the custom AUTO programs CUS. 01CUS. 10 When activating the custom AUTO programs CUS. 01 to CUS. 10 then it is possible to control the STEP TIME and FADE TIME using CH2 and CH3 respectively. CH8 has priority over CH2, CH3, CH4, CH5, CH6 & CH7.
DIMMER SPEED
CH10 is for selecting the dimmer mode and dimmer speed. When DIMMER is set to Off , then RGBW and MASTER DIMMER are linear. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BEGLEC LED MEGA BEAM
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.