User manual BEGLEC LED MINI PAR V1.0

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BEGLEC LED MINI PAR. We hope that this BEGLEC LED MINI PAR user guide will be useful to you.

Lastmanuals help download the user guide BEGLEC LED MINI PAR.


Mode d'emploi BEGLEC LED MINI PAR
Download

You may also download the following manuals related to this product:

   BEGLEC LED MINI PAR V2.1 (3400 ko)

Manual abstract: user guide BEGLEC LED MINI PARV1.0

Detailed instructions for use are in the User's Guide.

[. . . ] Direct input of DMX512 signal allows the units to be controlled from any DMX512 controller. This product can be operated as a single unit or in multiple units for large applications. The specially developed controller that allows the product to be controlled independent of the DMX512 controller enables the user to create and edit a wide range of custom programs. [. . . ] Do not touch the power cables if your hands are wet. ATTENTION This product left the place of manufacture in perfect condition. In order to maintain this condition and for safe operation, the user must always follow the instructions and safety warnings described in this user manual. Avoid shaking or strong impacts to any part of the equipment. Make sure that all parts of the equipment are kept clean and free of dust. Always make sure that the power connections are connected correct and secure. If there is any malfunction of the equipment, contact your distributor immediately. When transferring the product, it is advisable to use the original packaging in which the product left the factory. Shields, lenses or ultraviolet screens shall be changed if they have become damaged to such an extent that their effectiveness is impaired. The lamp (LED) shall be changed if it has become damaged or thermally deformed. 1 PRODUCT(GENERAL) 4 2008. 8. 13 2 2. 1 INSTALLATION MOUNTING HANGING The LED PAR can be mounted in a hanging position using the supporting bracket. The bracket should be secured to the mounting truss or structure using a standard mounting clamp. Please note that when hanging the unit a safety cable should also be used. UPRIGHT The LED PAR can be mounted in an upright or sitting position using the supporting brackets. The LED MODULE can be mounted at any angle and in any position. It is possible to further adjust the angle of the LED MODULE using the two adjustment knobs located on the side of the fixture. 2. 2 POWER CONNECTIONS @ 220V: 40 units may be connected in series @120V: 20 units may be connected in series Note: As this fixture's DMX signal cable connection had been changed to Parallel connection, so if over 30 units to be connected, then a DMX signal amplifier is needed. 2 INSTALLATION 5 2008. 8. 13 2. 3 SETTING UP WITH A DMX512 CONTROLLER 2. 3-1 DMX512 ADDRESSING WITHOUT ID ADDRESSING (STAGE 1 MODE) Connect the DMX512 controller to the units in series. Each unit has 9 DMX channels so the DMX Addresses should increase by increments of 9 (e. g. 1, 10, 19, 28. . . ) The ID address has not been set so therefore when using the controller Ch9 must be inactive ( CH9=0 ). Each DMX Address may be used as many times as required. Any DMX address in the range from 001 to 512 may be used. Example: DMX Addr. 1 DMX Addr. 10 DMX Addr. 19 DMX512 CONTROLLER The figure above shows a simple DMX512 layout with the starting address of the first unit set at 1, with the second set at 10 and so on. . . [. . . ] This function will reset all setting to the original factory setting Up load custom?to upload the custom programs from the current MASTER unit to the SLAVE units 3. 11 MENU PASSWORD PASSWORD ON/OFF PASSWORD Enter the PASSWORD mode to select whether the access password is on or off. When the fixture is set as PASS ON , after 30 seconds or turn on the fixture next time, the fixture will need an access password to enter the display menu control. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BEGLEC LED MINI PAR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BEGLEC LED MINI PAR will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag