User manual BEGLEC LED POWER BANK V1.0 FIRMWARE V12
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BEGLEC LED POWER BANK. We hope that this BEGLEC LED POWER BANK user guide will be useful to you.
Lastmanuals help download the user guide BEGLEC LED POWER BANK.
You may also download the following manuals related to this product:
BEGLEC LED POWER BANK V1.1 FIRMWARE V17 (2360 ko)
Manual abstract: user guide BEGLEC LED POWER BANKV1.0 FIRMWARE V12
Detailed instructions for use are in the User's Guide.
[. . . ] Ver 1, 0 (firmware V12)
USER MANUAL
T
ABLE OF CONTENTS
TABLE OF CONTENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I. PART 1 PRODUCT (GENERAL). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.
1. 1--PRODUCT INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2. 1. 2--PRODUCT FEATURES. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2. 1. 3--TECHNICAL SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3. [. . . ] 1, 2, 3. . . Not required for WASH programs). ID ON should be set in the Settings menu on each unit. When using the PIX CONTROLLER with the fixtures there is no need to set the DMX address. When using the Effect programs it is important to set the Range of fixtures in the Settings menu of the PiX CONTROLLER.
Example:
ID Addr. 1 ID Addr. 2 ID Addr. 3
ID Addr. 4
ID Addr. 5
ID Addr. 6
ID Addr. 7
ID Addr. 8
ID Addr. 9
CONTROLLER
MOD E
SETU P
UP
DO WN
In the figure above the PiX controller is connected in series to 9 units with corresponding ID addresses from 1 to 9. Each fixture has ID ON in the fixture's Settings menu. In order to activate the Effect programs in the PIX CONTROLLER, the Range must be set to 009 in the Settings menu of the PIX CONTROLLER. (Note: it is possible to create different kinds of effects by changing the direction and position of ID Addresses)
2 INSTALLATION
12
2007. 9. 8
2. 5-3 REPEAT ROW BLOCK APPLICATION
Connect the fixtures to the PIX CONTROLLER in series. ID Address should be set in the Settings menu on each unit in ascending order with each row repeated (Not required for Wash programs). ID ON should be set in the Settings menu on each unit. When using the PRO-a CONTROLLER with the fixtures there is no need to set the DMX address. When using the Effect programs it is important to set the Range of fixtures in the Settings menu of the PRO-a CONTROLLER.
Example:
ID Addr. 1 ID Addr. 2 ID Addr. 3
ID Addr. 1
ID Addr. 2
ID Addr. 3
ID Addr. 1
ID Addr. 2
ID Addr. 3
CONTROLLER
MOD E
SETU P
UP
DO WN
In the figure above the PIX controller is connected in series to 9 fixtures with each row comprising of 3 fixtures with corresponding ID addresses from 1 to 3. Each row is repeated so that the ID addresses appear the same was as the first row. Each fixture has ID On in the fixture's Settings menu. In order to activate the Effect programs in the PIX CONTROLLER, the Range must be set to 003 in the Settings menu of the PIX CONTROLLER.
2 INSTALLATION
13
2007. 9. 8
2. 6
OPERATION: DMX512 Vs PiX CONTROLLER
OPERATION WITH A DMX512 CONTROLLER
AVAILABLE FUNCTIONS
BENEFITS
DRAWBACKS
DMX512 ADDRESS ID ADDRESS
X
Basic WASH Programming
X
Advanced WASH & EFFECT programming
No need to set up DMX Address or ID Address
Must locate previosly stored DMX Address
DMX512 ADDRESS ID ADDRESS
Units are fully controlled from DMX512 controller
X X
Programming requires many DMX channels No auto programs
DMX512 ADDRESS ID ADDRESS
Basic WASH programming & ADAS
DMX Address ID address allows for less DMX channels when programming* ADAS User can switch be tween ADAS & real DMX address Advanced fixture mapping
No auto programs All ID addresses must be set
DMX512 ADDRESS ID ADDRESS
Advanced WASH & EFFECT programming & ADAS
No auto programs All ID addressesmust be set
OPERATION WITH THE PiX CONTROLLER
AVAILABLE FUNCTIONS
BENEFITS
DRAWBACKS
DMX512 ADDRESS ID ADDRESS
X X
Play WASH auto programs, Basic CUSTOM programming & Schedule play Play WASH auto programs, Basic CUSTOM programming & Schedule play Play WASH & EFFECT auto programs, Advanced CUSTOM programming & Schedule play
No need to set up DMX Address or ID Address
Only control of all units at the same time
DMX512 ADDRESS ID ADDRESS
DMX address not used
Only control of all units at the same time
X X
DMX512 ADDRESS ID ADDRESS
DMX Address not used Control speed and time of all WASH & EFFECT programs Create powerful CUSTOM programs Schedule play Trigger auto programs with DMX IN DMX Address not used Control speed and time of all WASH & EFFECT programs Create powerful CUSTOM programs Schedule play Trigger auto programs with DMX IN
All ID Addresses must be set
DMX512 ADDRESS ID ADDRESS
Play WASH & EFFECT auto programs, Advanced CUSTOM programming & Schedule play
All ID Addresses must be set
2 INSTALLATION
14
2007. 9. 8
3
DISPLAY PANEL OPERATION
3. 1 3. 2 3. 3 3. 4 3. 5 3. 6 3. 7 3. 8
BASIC MENU CREATING A STATIC COLOR DMX512 SETTINGS ACTIVATING AN AUTO PROGRAM CHANGING THE SETTINGS A CTIVATE THE PASSWORD POWER ON/OFF
3 DISPLAY PANEL OPERATION
15
2007. 9. 8
3. 1
BASIC
The LED fixture is mounted with a LCD display and 4 control buttons.
SET
UP
DOWN
EXIT
enter the currently selected menu or confirm the current function value scroll 'UP' through the menu list or increase the value of the current function scroll 'DOWN' through the menu list or decrease the value of the current function exit from the current menu or function
3 DISPLAY PANEL OPERATION
16
2007. 9. 8
3. 2
MENU
MENU
Static color Dimmer Red Green Blue Color macros Strobe Dimmer Red Green Blue Colormacros Strobe 0 0 0 0 0 0 255 255 255 255 255 255
DMX512
Address Personality
Address 1 STAGE 1 STAGE 2 ARC 1
512
Auto program
Auto Auto Auto Auto Auto Auto Auto Auto
1 2 3 4 5 6 7 8
Set ti n gs
ID address
ID address 001 066
ID ON/OFF
ID ON/OFF
RAS ON/OFF
RAS ON/OFF ADAS ON/OFF ADAS fader no 01 244 Copy ON/OFF Reset confirm
ADAS ON/OFF
ADAS fader no
Copy ON/OFF
R e se t to Factory settings
MENU
Passw ord
Password ON/OFF
Password ON/OFF Set Password
Set password
3 DISPLAY PANEL OPERATION
17
2007. 9. 8
3. 3
CREATING A STATIC COLOR
MENU
Static color Dimmer Red Green Blue Color macros Strobe Dimmer Red Green Blue Colormacros Strobe 0 0 0 0 0 0 255 255 255 255 255 255
Static colour Combine RED, GREEN and BLUE to create an infinite range of colors (0-255) Enter Color macros allow to choose 18 color macros Set value of dimmer (0-255) Set the value of the strobe (0-20Hz)
3. 4
DMX512 SETTINGS
MENU
DMX512 Address Personality Address 1 STAGE 1 STAGE 2 ARC 1 512
DMX512 address Enter the DMX address mode to set the DMX address Activate control from outside source by activating ON Enter Personality mode to choose DMX mode: STAGE 1 ARC 1
, STAGE 2
or
3 DISPLAY PANEL OPERATION
18
2007. 9. 8
3. 5
ACTIVATING AN AUTO PROGRAM
MENU
Auto program Auto Auto Auto Auto Auto Auto Auto Auto 1 2 3 4 5 6 7 8
Auto Program Select the target Auto mode and press Set to display
3. 6
CHANGING THE SETTINGS
MENU
Set ti n gs ID address ID address 001 066 ID ON/OFF
ID ON/OFF
RAS ON/OFF
RAS ON/OFF ADAS ON/OFF ADAS fader no 01 244 Copy ON/OFF Reset confirm
ADAS ON/OFF
ADAS fader no
Copy ON/OFF
R e se t to Factory settings
Settings Enter the ID Address to set the ID address for the unit Enter ID ON/OFF in order to allow/disallow ID address function from the DMX512 controller RAS ON/OFF reserve for future use. In ADAS ON/OFF select allow/disallow Automatic DMX512 Addressing System (ADAS) Enter the ADAS fader no to set the number of channel faders in each layer of the controller In the Copy ON/OFF menu select whether to allow copy of DMX and ID address to unit. Enter the Reset to Factory Settings in order to reset to default factory settings.
3 DISPLAY PANEL OPERATION
19
2007. 9. 8
3. 7
A CTIVATE THE PASSWORD
MENU
Passw ord O N / OF F Set Password Password ON/OFF Password
Enter the
Password mode to set password YES/NO
When password is activated, display will demand password each time the fixture is powered on. Enter the Set password menu to change password. Set new password using the UP & DOWN keys. Input an 8 digit password and then press SET to confirm NOTE: In the event that the password is forgotten. Please use the factory password shown below. UP > DOWN > UP > DOWN > UP > UP > DOWN > DOWN
3. 8
POWER ON/OFF
TURN OFF When display shows MENU , hold down the EXIT key for 3 seconds to turn off power. TURN ON When display is off, hold down the EXIT key for 3 seconds to turn on power.
3 DISPLAY PANEL OPERATION
20
2007. 9. 8
4
USING A DMX512 CONTROLLER
4. 1 4. 2 4. 3 4. 4 BASIC ADDRESSING CHANNEL ASSIGNMENT BASIC INSTRUCTIONS FOR DMX512 OPERATION PROGRAMMING WITH A DMX512 CONTROLLER: EXAMPLES
4 USING A DMX512 CONTROLLER
21
2007. 9. 8
4. 1
BASIC ADDRESSING
Connect all of the units in series using standard DMX512 signal cable or the IP65 rated cable provided. [. . . ] 1 to select RED for all MODULES (ID Add. 2) to select NO GREEN for all MODULES (ID Add. 2) to select NO BLUE for all MODULES (ID Add. 2) to select DMX MODE 1 to select ID Add: 2
ID Addr. 1 ID Addr. 2 ID Addr. 1 ID Addr. 2
Step 7
CH3 CH9 CH10 CH1 CH2
Step 8
CH3 CH9 CH10
Red
Green
Blue
4 USING A DMX512 CONTROLLER
38
2007. 9. 8
EXAMPLE 3
Before any operation is performed on the DMX512 controller, confirm that all DMX channels are set to zero.
CH1 CH2
255 0 0 0 11 0 255 0 0 12 0 0 255 0 13 0 0 0 0 11 0 0 0 0 12
to select RED for all MODULES (ID Add. 1) to select NO GREEN for all MODULES (ID Add. 1) to select NO BLUE for all MODULES (ID Add. 1) to select DMX mode 1 to select ID Add. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BEGLEC LED POWER BANK
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BEGLEC LED POWER BANK will begin.