Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BEGLEC SMART BEAM. We hope that this BEGLEC SMART BEAM user guide will be useful to you.
Lastmanuals help download the user guide BEGLEC SMART BEAM.
Detailed instructions for use are in the User's Guide.
[. . . ] 3. 8--ID ADDRESS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3. 9--EDITING CUSTOM PROGRAMS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3. 10--SPECIAL SETTINGS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12. 3. 11--WHITES SETTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13. [. . . ] Always operate the equipment as described in the user manual. A minimum distance of 0. 5m must be maintained between the equipment and combustible surface. The product must always be placed in a well ventilated area. Always make sure that the equipment is installed securely. DO NOT stand close to the equipment and stare directly into the LED light source. Always disconnect the power supply before attempting and maintenance. Always make sure that the supporting structure is solid and can support the combined weight of the products. The earth wire must always be connected to the ground. Do not touch the power cables if your hands are wet.
ATTENTION
This product left the place of manufacture in perfect condition. In order to maintain this condition and for safe operation, the user must always follow the instructions and safety warnings described in this user manual. Avoid shaking or strong impacts to any part of the equipment. Programs AT. 0 1 to AT. 1 0 are fully pre-programmed and will not be altered by changes in EDIT mode. Programs PR. 01 to PR. 10 are fully pre-programmed and can be edited in EDIT mode.
3 DISPLAY PANEL OPERATION
10
2009. 11. 10
3. 6
DMX512 SETTINGS
DMX Enter the DMX mode to set the DMX ADDRESS.
3. 7
PERSONALITY
PERSONALITY Enter the PERSONALITY mode to select DMX mode: TOUR Ar1. d , Ar1. s or HSV . , Arc. 1 ,
3. 8
ID ADDRESS
ID Enter the ID mode to set the ID ADDRESS.
3 DISPLAY PANEL OPERATION
11
2009. 11. 10
3. 9
EDITING CUSTOM PROGRAMS
EDIT CUSTOM Enter the EDIT mode to edit the custom programs PR. 01 to PR. 10 . Each custom program has 30 steps that can be edited. Each step allows the creation of a scene using RED Red , GREEN Green BLUE Blue , STROBE Strobe , TIME Time & FAD E Fade .
,
3. 10
SPECIAL SETTINGS
SETTING Select UPLD to upload the custom programs from the current MASTER unit to the SLAVE units. In order to activate the upload function the password must be entered. Password is the same as the main access password. When uploading the MASTER and SLAVE units will display YELLOW. If an error occurs when uploading the MASTER and/or SLAVE units will display RED. On successful uploading of the custom programs the MASTER and SLAVE units will display GREEN. In order to reset custom modes to default values select REST . [. . . ] When the fixture is set as PASS ON , after 30 seconds or turn on the fixture next time, the fixture will need an access password to enter the display menu control. Note: The factory access password is UP + DOWN then press ENTER to confirm the access. + UP + DOWN ,
3 DISPLAY PANEL OPERATION
13
2009. 11. 10
4 USING A DMX512 CONTROLLER
4. 1 BASIC ADDRESSING
Connect all of the units in series using standard DMX512 signal cable or the IP65 rated cable provided. It is possible to have the same DMX address or independent addresses for each fixture.
4. 2
CHANNEL ASSIGNMENT
Note: This product have three DMX512 channel configuration: Arc. 1 , Ar1. d , Ar1. s and HSV TOUR ,
TOUR
4 USING A DMX512 CONTROLLER
14
2009. 11. 10
4 USING A DMX512 CONTROLLER
15
2009. 11. 10
4 USING A DMX512 CONTROLLER
16
2009. 11. 10
4 USING A DMX512 CONTROLLER
17
2009. 11. 10
4. 3
BASIC INSTRUCTIONS FOR DMX512 OPERATION (TOUR)
MASTER DIMMER CH1 controls the intensity of the currently projected color When the slider is at the highest position (255) the intensity of the output is the maximum RED, GREEN & BLUE COLOR SELECTION CH2, CH3 & CH4 control the intensity ratio of each of the RED, GREEN, BLUE & WHITE LEDs. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BEGLEC SMART BEAM
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BEGLEC SMART BEAM will begin.