User manual BEHRINGER UB1204-PRO

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BEHRINGER UB1204-PRO. We hope that this BEHRINGER UB1204-PRO user guide will be useful to you.

Lastmanuals help download the user guide BEHRINGER UB1204-PRO.


Mode d'emploi BEHRINGER UB1204-PRO
Download

You may also download the following manuals related to this product:

   BEHRINGER UB1204-PRO TECHNICAL SPECIFICATIONS (907 ko)

Manual abstract: user guide BEHRINGER UB1204-PRO

Detailed instructions for use are in the User's Guide.

[. . . ] EURORACK UB1204-PRO/UB1204FX-PRO Users Manual Version 1. 3 February 2006 EURORACK UB1204-PRO/UB1204FX-PRO IMPORTANT SAFETY INSTRUCTIONS DETAILED SAFETY INSTRUCTIONS: 1) Read these instructions. CAUTION: To reduce the risk of electric shock, do not remove the top cover (or the rear section). No user serviceable parts inside; refer servicing to qualified personnel. 5) Do not use this apparatus near water. [. . . ] If STEREO AUX RETURN 1 is used as effects return, you can add the effects signal to any dry channel signal. + In this instance, the effects device should be set at 100% effect. Fig. 2. 11: Control room/phones section, level meter TAPE The TAPE switch routes the signal from the TAPE IN connectors to the level meter, the CONTROL ROOM OUT outputs and the PHONES connectorthis is a simple way to check recorded signals via monitor speakers or headphones. ALT 3-4 Similarly, the ALT 3-4 switch routes the signal from the Alt 3-4 bus to the same path for monitoring purposes. MAIN MIX The MAIN MIX switch sends the main mix signal to the abovementioned outputs and to the level meter. CTRL R & PHONES Use this control to set control room output level and headphones volume respectively. TAPE TO MAIN When the TAPE TO MAIN switch is depressed, the 2-track input is routed to the main mix and thus serves as an additional input for tape machines. You can also connect MIDI instruments or other signal sources here that do not require any further processing. At the same time, this switch disables the main mix to tape output link. POWER The blue POWER LED indicates that the device is switched on. +48 V The red +48 V LED lights up when the phantom power supply is switched on. The phantom power supply is necessary for condenser microphones and is activated using the switch on the rear of the device. STEREO AUX RETURN MON The STEREO AUX RETURN MON control has a special function: it can be used to add an effect to a monitor mix. For example: Monitor mix with effect In this instance, the effects device should be set up as follows: AUX SEND 2 is connected to the L/Mono input of your effects device, while its outputs are connected to STEREO AUX RETURN 1. Connect the amplifier of your monitor system to AUX SEND 1. The AUX SEND 1 master control determines the volume of the monitor mix. You can now use the STEREO AUX RETURN MON control to adjust the level of the effects signal routed to the monitor mix. You can easily use the headphones distribution amplifier BEHRINGER POWERPLAY PRO HA4600/HA4700/HA8000 to provide you with four (or eight with the HA8000) stereo headphone mixes for your studio. STEREO AUX RETURN 2 (FX) The STEREO AUX RETURN 2 control determines the level of signals fed into the AUX RETURN 2 connectors which are routed to the main mix. MAIN MIX/ALT 3-4 The MAIN MIX/ALT 3-4 switch routes the signal connected to STEREO AUX RETURN 2 to either main mix (not pressed) or submix (Alt 3-4, pressed). 2. 3. 5 Tape input / tape output + Fig. 2. 10: 2-track connectors TAPE INPUT The TAPE INPUT RCA connectors are provided for connecting a 2 track machine (e. g. They can also be used as stereo line input. Alternatively, the output signal of a second EURORACK or BEHRINGER ULTRALINK PRO MX882 can also be connected. If you connect a hi-fi amplifier with a source selection switch to the TAPE INPUT, you can easily switch between additional sources (e. g. [. . . ] damages/defects caused by force majeure or any other condition that is beyond the control of BEHRINGER. s 5. Any repair or opening of the unit carried out by unauthorized personnel (user included) will void the warranty. If an inspection of the product by BEHRINGER shows that the defect in question is not covered by the warranty, the inspection costs are payable by the customer. Products which do not meet the terms of this warranty will be repaired exclusively at the buyers expense. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BEHRINGER UB1204-PRO

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BEHRINGER UB1204-PRO will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag