[. . . ] The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report requires the prior written approval of the CETECOM Inc USA. TEST REPORT PREPARED BY: EMC Engineer: Philip Kim 1. 2 Testing laboratory CETECOM Inc. [. . . ] Garn, Austrian Research Centre, Seibersdorf). The test results of the anechoic chamber correspond to the 10m-OATS results
Test setup
EUT was setup in an anechoic chamber
Limits
Freq. Range 30MHz 230MHz 230MHz 1000MHz Limit (Quasi peak) 30dBµV/m 37dBµV/m
EUT Type and S/N or EUT set-up no. angle of turntable 0 º - 360º polari-sation (h / v) h/v comment (e. g. operating mode or operating mode no. ) EUT operating mode 3 result (passed / failed) Passed
Remarks: All measurements were carried out in peak mode. As long as the values stay under the average limit line No QP measurements are carried out.
CETECOM Inc.
Test report no. :EMC_381EN489-17_2002 Issue date:2003-01-10 Page 10 (25)
AC LINE CONDUCTED EMISSIONS According to EMC basic standard (EN 55022 [7] Class-B) 1. For the table top EUT the distance to the reference ground plane (wall) should be 40 cm. 2. AC input line plugged into LISN EUT Operating mode Tx at middle. channel
Plot no.
Powerline (L, N)
EUT operating mode or operating mode no.
Detector (Peak, AV, QP) QP
--
L+N
Additional (scan-) information (e. g. Pre-test Fastscan, Maxhold, Final measurement) Final measurement
Result (passed / failed ) N/A
Note: This test does not apply due to the fact that EUT's power is host dependant.
CETECOM Inc.
Test report no. :EMC_381EN489-17_2002 Issue date:2003-01-10 Page 11 (25)
HARMONIC CURRENT EMISSIONS This test was performed as per EMC Basic Standard EN 61000-3-2(Dec-2000) EUT Operating mode Tx at middle. --
Port AC input
EUT operating mode or operating mode no. channel
Result (passed / failed ) N/A
Note: This test does not apply due to the fact that EUT's power is host dependant.
CETECOM Inc.
Test report no. :EMC_381EN489-17_2002 Issue date:2003-01-10 Page 12 (25)
FLICKER AND VOLTAGE FLUCTUATION This test was performed as per EMC Basic Standard EN 61000-3-3 EUT Operating mode Tx at middle. --
Port AC input
EUT operating mode or operating mode no. channel
Result (passed / failed ) N/A
Note: This test does not apply due to the fact that EUT's power is host dependant.
CETECOM Inc.
Test report no. :EMC_381EN489-17_2002 Issue date:2003-01-10 Page 13 (25)
IMMUNITY TEST: RADIATED, RF ELECTROMAGNETIC FIELDS According to EMC basic standard (EN 61000-4-3[9]) · The distance between the turn-table axis and TX-antenna is 3m. · Field strength = 3V/m · Start Frequency = 80MHz Stop Frequency = 1000MHz · Frequency Step = lin 1MHz · Modulation = AM, 1KHz, 80% Failure Criteria Describe applicable failure criteria for EUT Example 1. Continuous data transfer between EUT and Mini PCI Access Point 2. Transmitting following data: 65 bytes from 192. 168. 1. 1 icmp_seg = xxx + H = 255 time = xxx 3. If connection drops then the the program will display "Request Timed out" Failure Criteria obesrved Describe how failure criteria was observed Example 1. Observe continuous scrolling "# " on the screen
Plot no. 5. 1 5. 2
Antenna Polarity vertical horizontal
Radiation to Front Front
Reaction of the EUT During and after test No reactions recognized No reactions recognized
Result passed passed
Performance criteria A observed
CETECOM Inc.
Test report no. :EMC_381EN489-17_2002 Issue date:2003-01-10 Page 14 (25)
RF COMMON MODE According to EMC basic standard (EN 61000-4-6[10]) Start Frequency = 150KHz Stop Frequency = 80MHz Frequency Step = 50KHz in the range of 150KHz 5MHz 1% increment in the range of 5MHz 80MHz Field strength = 3V/m Modulation = AM, 1KHz, 80% Test setup Injection via CDN or BIC clamp Failure Criteria Failure Criteria obesrved
Plot no. --
Injection on AC input power line
Injection Via CDN
Reaction of EUT during and after test No reactions recognized
Result N/A
Performace criteria A observed
Note: This test does not apply due to the fact that EUT's power suuply is host dependant.
CETECOM Inc.
Test report no. :EMC_381EN489-17_2002 Issue date:2003-01-10 Page 15 (25)
ELECTROSTATIC DISCHARGE According to EMC basic standard (EN 61000-4-2[10]) For the table top EUT the distance to the reference ground plane should be 80 cm. Direct contact discharge on conducting surfaces of EUT Indirect air discharge on insulating surfaces of EUT ±2kV, ±4kV direct discharge & ±2kV, ±4kV, ±8KV air discharger Test setup Failure Criteria Failure Criteria obesrved
10 Single impulses at each test point and for each test voltage Contact discharge to conducted surfaces and to coupling planes Direct contact discharge Indirect contact discharge Test voltage Reaction of EUT / result Reaction of EUT / result +2 kV n. r. r. [. . . ] Rohde & Schwarz Voltech Rhode & Schwarz Rhode & Schwarz Type/Model ESIB 40 CMU 200 PMI FSEM 30 CMD 55 UPL 16 SMY02 NRVD URV5-Z2 URV5-Z2 250W1000 3051G3 100A 250AM1 VT4004 6520 ESH 3-Z6 ESH3-Z5 UCS 500 M4 11667B JS4-00102600 AFS4-00101 System integrated System integrated System integrated 5HC2700 5HC2700 4HC1600 4HC1600 System integrated System integrated E3610A E3610A 50FHE-006-200 776B-10 770B-10 1433-3 --IEC Standard 555 URV5-Z2 URV5-Z2 Serial No. 100107 101821 304644 826880/010 847958/008 838205/005 836878/011 836875/020 836029/034 836029/035 300031 29254 28835 G1115 2098 836154/011 836679/003 28259 28256 28256 645348 00616 800-55-LN
9926013 9926014 9922307 9922308 ----KR83021224 KR83023316 319740 0051 5173 --MG678 836154/04 IB27/2233 DE30807 DE30808
CETECOM Inc.
Test report no. :EMC_381EN489-17_2002 Issue date:2003-01-10 Page 23 (25)
No 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81
Instrument/Ancillary Log periodic Antenna Log periodic Antenna Biconical Antenna Biconical Antenna Biconical Antenna Biconilog Antenna Horn Antenna Horn Antenna Horn Antenna Horn Antenna Coupling Clamp 125W Coupling Clamp Decoupling Clamp Calibration Fixture Calibration Fixture CDN CDN CDN CDN CDN CDN CDN CDN Isotropic Field Probe Current Probe 10K-500M Current Probe 10K-230M Probe Set (9K-1G) Passive Impd. Adaptor Audio Box TS-SBOX Acoustic Calibrator Mouth Simulator Telephone test head Probe Microphone Nexus Conditioning Ampl. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BELKIN F5D7010CE2
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.