If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BELKIN F6C650-SER-SB. We hope that this BELKIN F6C650-SER-SB user guide will be useful to you.

Lastmanuals help download the user guide BELKIN F6C650-SER-SB.


Mode d'emploi BELKIN F6C650-SER-SB
Download
Manual abstract: user guide BELKIN F6C650-SER-SB

Detailed instructions for use are in the User's Guide.

[. . . ] P73506-UPS manual S-series. qxd 2/28/01 1:34 PM Page 1 OPERATION Switch On With the UPS plugged in, press and hold the on/off/test button for more than three seconds until the "ON LINE" LED lights up to switch the UPS on. The UPS will perform self-testing each time it is switched on. Note: The UPS maintains the battery charge when in the off position. Switch Off Press and hold the on/off/test button for more than three seconds until the "ON LINE" or "ON BATTERY" LED goes off. [. . . ] Charge the Battery For best results, charge the battery for six hours prior to initial use. The UPS charges its battery whenever it is connected to the utility power. ALARM Backup (Slow Alarm) When in "BACKUP" mode, the GREEN LED illuminates and the UPS sounds an audible alarm. The alarm stops when the UPS returns to LINE NORMAL operation. Low Battery (Rapid Alarm) In "BACKUP" mode, when the battery energy runs low, the UPS beeps rapidly until the UPS shuts down from a depleted battery or returns to LINE NORMAL operation. Overload (Continuous Alarm) When the UPS is overloaded (the connected loads exceed the maximum rated capacity) the UPS emits a continuous alarm to warn of an overload condition. Disconnect nonessential equipment from the UPS to eliminate the overload. Fault (10 Seconds Continuously) When the output is shorted, the UPS emits a 10-second alarm. Disconnect the equipment from the UPS prior to checking the equipment. FRONT PANEL Press the button longer than three seconds to turn the UPS on or off. Press the button less than three seconds to activate the UPS self-testing or to silence the backup alarm. Low Battery/Replace Battery Fault/Overload COMMUNICATION INTERFACE Belkin Sentry Bulldog Shutdown Management Software and RS232 cable can be used with this UPS. If used, connect the interface cable to the computer interface port on the rear panel of the UPS, and then connect to the serial port on your PC. The communication port provides the following features: 1) Monitors charger status 2) Monitors UPS status 3) Monitors battery status and condition 4) Monitors the utility status 5) Provides power-switch function for power saving REAR PANEL Interface Port Provides RS232 to relay the signal to support DOS, Windows, and other operating systems. Phone/Fax/Modem/DSL or Network Protection Telephone/fax/modem lines are surge protected and provide complete safety for Internet connection. One input and one output allow two devices to be protected (i. e. modem and fax). On Line/On Battery On/Off/Test P73506-UPS manual S-series. qxd 2/28/01 1:34 PM Page 2 SOFTWARE OPTIONS Belkin Sentry Bulldog Shutdown Management Software Belkin Sentry Bulldog Shutdown Management Software receives communication through the RS232 interface port to perform monitoring functions, and also provide an orderly shutdown of the computer in the event of a power failure. Moreover, Belkin Sentry Bulldog Shutdown Management Software displays all of the diagnostic symptoms on screen, such as voltage level, frequency, battery level, etc. The software is available for Windows® 95, Windows® 98, Windows NT® V4 or higher, Windows® 2000, Windows® Me, Unix®, and Novell® 3. X and above. Interface Kits Each interface kit includes a special interface cable which is required to convert status signals from the UPS into signals that the individual operation system can recognize. The interface cable must be connected to the (RS232) serial port on the UPS. The other side of the interface cable can be connected to the DB9 serial port on your PC. For other installation instructions and features, please refer to the READ. ME file. Caution: Use only factory supplied or UPS monitoring cable! STORAGE Storage Conditions Store the UPS covered and upright in a cool, dry location, with its battery fully charged. Before storing, charge the UPS for at least four hours. [. . . ] Use your the battery and slide the thumb to open the battery battery out. cover on the bottom of the unit. BELKIN COMPONENTS USER LICENSE AGREEMENT Belkin Components ("Belkin") thanks you for choosing one of our products for your use. This User License Agreement ("Agreement") contains the terms and conditions under which limited use of the product is licensed to you. PLEASE READ THIS NOTICE CAREFULLY DO NOT OPEN THIS ENVELOPE OR USE ANY OF THE SOFTWARE UNTIL YOU HAVE READ AND AGREED TO THIS AGREEMENT. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BELKIN F6C650-SER-SB

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BELKIN F6C650-SER-SB will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag