User manual BELKIN PMS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BELKIN PMS. We hope that this BELKIN PMS user guide will be useful to you.

Lastmanuals help download the user guide BELKIN PMS.


Mode d'emploi BELKIN PMS
Download
Manual abstract: user guide BELKIN PMS

Detailed instructions for use are in the User's Guide.

[. . . ] Belkin Power Management Software Uninterruptible Power Supply Software User's Manual For Microsoft Windows 98 Microsoft Windows NT Microsoft Windows 2000 Microsoft Windows Me Microsoft Windows XP Microsoft Windows 2003 Linux, FreeBSD Contact Belkin Corporate Headquarters Belkin Corporation 501 West Walnut Street Compton · CA · 90220-5221 · USA Tel: 310. 898. 1100 Fax: 310. 898. 1111 Customer Service/Sales: 800. 2BELKIN 800. 223. 5546 Technical Support: 310. 898. 1100 ext. 2263 Fax: 310. 604. 2089 techsupp@belkin. com belkin. com/support/tech United Kingdom Belkin, Ltd. Express Business Park Shipton Way · Rushden · NN10 6GL United Kingdom Tel: +44 (0) 1933 35 2000 Fax: +44 (0) 1933 31 2000 European Customer Service/Sales: 00 800 223 55 460 eurosales@belkin. com European Tech Support: 00 800 223 55 460 eurosupport@belkin. com Belkin Power Management Software France Belkin SAS Components 5 rue du Petit Robinson 78 350 Jouy en Josas · France Tel: +33 (0) 1 34 58 14 00 Fax: +33 (0) 1 39 46 62 89 European Customer Service/Sales: 00 800 223 55 460 eurosales@belkin. com European Tech Support: 00 800 223 55 460 eurosupport@belkin. com Germany Belkin GmbH Hanebergstrasse 2 80637 · München · Germany Tel: +49 (0) 89 143405 0 Fax: +49 (0) 89 143405 100 European Customer Service/Sales: 00 800 223 55 460 eurosales@belkin. com European Tech Support: 00 800 223 55 460 eurosupport@belkin. com The Netherlands Belkin B. V. Starparc Building · Boeing Avenue 333 1119 PH Schiphol-Rijk · The Netherlands Tel: +31 (0) 20 654 7300 Belkin Power Management Software Fax: +31 (0) 20 654 7349 European Customer Service/Sales: 00 800 223 55 460 eurosales@belkin. com European Tech Support: 00 800 223 55 460 eurosupport@belkin. com Australia Belkin, Ltd. [. . . ] Power abnormal condition: All Events/AC Failure/AC Power Restored/UPS Battery Low/Recovered from Low. Please Press "Add/Modify/Delete" button to edit email address. 20 Belkin Power Management Software For sending all events to the same email account, select "All Events" and type the receiving email address. Following picture is the email contents that sent automatically by "Belkin Power Management Software": 21 Belkin Power Management Software Enable Pager: In this function, the users can set the messages to the system administrator by pager. The configuration's mode and screen is as below. Modem connected to: set the communication port, which connects with the Modem. If necessary, please input the prefix code for outside line first, then add ", " for 0. 5 second delay time, the full pager numbers at last. Code to send: you can input the event code for sending. 22 Belkin Power Management Software Send Notification to the same pager number Select this check box to send all messages to the same pager and enter the relevant pager number in the AC Failure field. For instance: Set the Modem connect to COM2 and dial "0" to access an outside line, and pager number is "0, 947123456" and "#1234#"means AC power failed. (Attention: The action should be done within 20 seconds from calling pager number to sending code transmission. ) D. Automatic Shutdown Time Parameters UPS allows the users some time to shut down the system before the UPS battery is exhausted. The characteristic configuration of the UPS makes it so the system can be restarted and operated normally. After AC Failure, Commence Computer Shutdown Sequence in: Set the continuous time for system operation after AC power fails. Please refer to the UPS hardware manual or consult to the UPS supplier before your configuration. . settings range:0~2880 mins . default value:10 mins If Low Battery Occurs, Commence Shutdown Sequence in: Set some time for system's continuous operation when battery low. For the setting value, the smaller is the better. . settings range:0 ~600 mins . default value:1 mins 23 Belkin Power Management Software Time Needed for Shutdown Sequence Before UPS Turn Off: Set time interval from when Windows shutdown to UPS power supply turn-off. It should be considered whether the time is enough for archiving before the system shutdown. The time for archiving would be different for the amount and the size of the opened files . . settings range0. 2 99 mins . default value:2 mins Pop-Up Warning Message Every: Set the time interval for displaying the warning messages. . settings range:10~600 secs . default value:30 secs 3. 4. 3. 3. Schedule Belkin Power Management Software can set the scheduled time for the UPS to turn on /off and self-test. Therefore, the system could be operated without the management from system supervisor. You can set what and how often the schedule execution is. The setting category and operating frequency are as below. 24 Belkin Power Management Software Actions . Turn on UPS . Shutdown Operating System and UPS . UPS Self-Test Until Battery Low . UPS Self-Test for 10 Secs Frequency . Once . Daily . Weekly . Monthly Setting method: press "Schedule" in function menu. [. . . ] Belkin Power Management Software configured to monitor the UPS from the serial port Short Description of Each Option [s] 10 Seconds Test UPS performs a 10 seconds self-test then returns to utility. [b] Test until Battery Low UPS performs self-test until battery becomes low. 55 Belkin Power Management Software [n] Shut Down UPS UPS stops providing output power after a few seconds. [a] Cancel Shut Down Command Cancel an impending UPS shutdown or turns on the UPS if utility is present. Belkin Power Management Software configured to monitor the UPS from an SNMP Agent Short Description of Each Option [s] Shut Down UPS UPS stops providing output power after a few seconds. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BELKIN PMS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BELKIN PMS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag