Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BENSHAW GP PRESENTATION. We hope that this BENSHAW GP PRESENTATION user guide will be useful to you.
Lastmanuals help download the user guide BENSHAW GP PRESENTATION.
Manual abstract: user guide BENSHAW GP PRESENTATION
Detailed instructions for use are in the User's Guide.
[. . . ] [. . . ] · Initial offering
1 - 5 HP 230V and 460V NEMA 1/IP31 convertible to Chassis/IP21
· Future offerings
115V 1Ph . 5 through 1. 5HP 230V 1Ph . 5 HP through 3 HP 230V 3Ph . 5 HP through 10 HP 460V & 575V through 10 HP
6
Features
· Series G type programming
Similar parameter and access
· Groupings maintained · Additional parameters added
"Comfortable" feel of original G Series
7
Features (cont'd)
· Pull-Apart control terminals
Easy wiring and replacement
· Bright LED display
Easily readable in poor lighting conditions No language issues
· On-The-Fly programming
Most parameters can be programmed while drive is running
· Full time ground fault protection
8
Features (cont'd)
· All features & parameters of G Series · Expanded parameter set
Up to 16 kHz carrier frequency
· Auto select feature
Available 1, 000 Hz output Available 0. 01 frequency setting, normal 0. 1Hz New DC braking options
· Internal or external braking resistors · Reflashable software if required
9
Features (cont'd)
· Programmable I/O functions
Pull Apart Terminals 2 analog speed inputs 6 digital inputs
· · · · 5 programmable 19 different functions Pull up or pull down logic 2 & 3 Wire start/stop control
10
Features (cont'd)
· Programmable I/O functions
2 Analog outputs for meters
· Includes offset and span adjustments · 6 different functions
2 digital outputs
· 2 output relays · 11 different functions
11
G to GP Feature Comparison
Basic Specification
HP Range @ 230V HP Range @ 460V Voltage Tolerance Standard Enclosure G 0. 5 - 5 1-5 +/-10% Chassis GP 1-5 1-5 +/- 15% Chassis/IP20 NEMA1/ IP31 Comment Future plans to 10 HP Future plans to 10 HP Expanded tolerance for World Power Systems NEMA 1 design can accommodate Chassis / IP20
12
G to GP Feature Comparison
Performance Specifications
G Frequency Range Low Speed Preformance Dynamic Braking GP 0 - 400 Hz 0 - 1000 Hz 100% Torque at 100% Torque at 3 6 Hz Hz Better low end torque Faster response to load Transistor Only, 30 - 75% Less that 25% (optional 100% changes and stopping with external capabilities resistors)
None
Comment Broad speed range for higher level applications
Torque Limit
4 Quadrant Programmable
Faster response
13
G to GP Feature Comparison
Keypad/Programming Specifications
Keypad G GP Eight keys for Eight keys for programming & programming & operation operation Four digit LED Four Digit LED with 8 LED indicators Scrolling Scrolling parameter parameter list list - on the fly stop mode only Factory or Factory or Custom Custom Reset Reset Comment Different Look, same style operation Better Visability in Low Light Familiar parameter numbering - easier accessibility Quick easy method to return drive to known condition
Display Programming
Factory Reset
14
G to GP Feature Comparison
Terminal Strip Specifications
Terminal Strip Digital Inputs Comment Easier initial wiring and swap-out More flexible for retrofits Six terminals Six terminals with Programmable to 17 and new installations predefined conditions operation One Relay Fault Only One Input for Voltage or Current Two Relays, 11 Functions Two Inputs Programmable Simplifies customer connections Flexibility for process control applciations G Fixed GP Pull Apart
Digital Outputs Analog Inputs
One - Voltage only Two - One voltage, Easy interface to remote one current devices for speed or load indication 24V User Supply No external supply is None 60 mA Current required for I/O Protected
15
Analog Outputs
G to GP Feature Comparison
Advanced Features
Available Parameters Switching Frequency V/Hz Characteristic Fault Protection Comment Additional flexibility 79 107 for tough applications Adjustable from 3 to 15 Adjustable from 4 to 16 Quiet motor operation kHz kHz 2 Multipiont V/Hz Six preset and a multi- Ability to profile the point mode output to match OEM requirements 17 faults - non37 faults - some Better annunciation of programmable programmable to warning problems and to help or no fault troubleshoot failures Not Available Standard with multiple Process control configurations advantage over similar cost competitors None ModBus Modbus is standard in every GP Drive G GP
PI Control
Field Bus Communication
16
GP Product
· Available on the WEB
Product is available for immediate delivery Fully support by Benshaw technical Customer Service Team
17 [. . . ] [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BENSHAW GP PRESENTATION
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BENSHAW GP PRESENTATION will begin.