Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BENSHAW RSI (H-SERIES) MODBUS CARD. We hope that this BENSHAW RSI (H-SERIES) MODBUS CARD user guide will be useful to you.
Lastmanuals help download the user guide BENSHAW RSI (H-SERIES) MODBUS CARD.
Manual abstract: user guide BENSHAW RSI (H-SERIES) MODBUS CARD
Detailed instructions for use are in the User's Guide.
[. . . ] The card supports four Modbus commands; Read Holding Registers (0x03), Read Input Registers (0x04), Preset Single Register (0x06) and Preset Multiple Registers (0x10).
2. Installation
2. 1 Card Layout
Standoff holes
ERR TXD RXD CPU
Indication LEDs
Connector to inverter main PCB
S GND T2
T1
N
P
Terminal block for Modbus connection
4
INSTALLATION
2. 2
1. 5.
Card Installation
Turn off the main power of Inverter. Wait until the DC bus capacitors are discharged. [. . . ] Registers can be read with either the Read Holding Registers command (0x03) or the Read Input Registers command (0x04). Those registers that may be changed can be done so using the Preset Single Register (0x06) or the Preset Multiple Registers command (0x10). A maximum of 8 registers can be read or written at a time.
3. 1
Mutual Group
The registers in the Mutual Group contain meter and status information that is not available in the other groups. Also, all of the registers from the Drive Group are duplicated in the Mutual Group. The values will only be used until power to the drive is lost. Once power is lost, these registers will return to the last values set through the Drive Group. To permanently change the command frequency, acceleration time or deceleration time, use registers 16384 (Cmd. time) instead.
Address Description R/W 10 11 hp 11 50 hp 12 60 hp 13 75 hp 14 100 hp 15 125 hp 0 220V Class 1 440V Class Software version in Binary Coded Decimal 0 Disable (default) 1 Enable 0 60000 Bit 0 Stop Bit 1 Forward Run Bit 2 Reverse Run Bit 3 Fault Reset Bit 4 Inverter Disable (coast to stop) Value 16 150 hp 17 200 hp 18 250 hp 20 300 hp 21 400 hp 22 500 hp Units
0001
Drive Horsepower
R
-
0002 0003 0004 0005
Drive Input Voltage Version Permit Parameter Write Cmd. (DRV 00)
R R R/W R/W
0. 01 Hz
0006
Run Command
R/W
-
0007 0008 0009 0010 0011
Acc. time (DRV 02) Current (DRV 03) Output Frequency Output Voltage
R/W R/W R R R
0. 1 sec 0. 1 sec 0. 1 A 0. 01 Hz 1V
7
MODBUS REGISTERS
Address 0012 0013
Description DC Bus Voltage Output Power (DRV 05)
R/W R R
Value
Units 1V 1W
0014
State
R
Bit 0 Stop Bit 1 Forward Run Bit 2 Reverse Run Bit 3 Fault (Trip) Bit 4 Accelerating Bit 5 Decelerating Bit 6 Output Frequency Arrival Bit 7 DC Braking Bit 8 Stopping Bit 13 Remote Run/Stop Bit 14 Remote Frequency Command Bit 0 OC Bit 1 OV Bit 2 EXT Bit 3 BX Bit 4 LV Bit 5 Fuse Open Bit 6 GF Bit 7 OH Bit 0 FX Bit 1 RX Bit 2 BX Bit 3 RST Bit 8 ETH Bit 9 OLT Bit 10 MCF Bit 12 SCT Bit 15 IOLT
-
0015
Trip Content
R
-
0016
Input Terminal Status
R
Bit 8 P1 Bit 9 P2 Bit 10 P3 Bit 11 P4 Bit 12 P5 Bit 13 P6
-
0017
Output Terminal Status
R
Bit 0 Q1 (OC1) Bit 1 Q2 (OC2) Bit 2 Q3 (OC3) Bit 3 AUX1 Bit 4 AUX2
-
0021
Speed (DRV 04)
R
RPM
3. 2
Drive Group
The registers in the Drive Group allow access to all of the parameters in the Drive Group that are available through the keypad.
Address 16384 16385 16386 16387 16388 16389 Keypad DRV 00 DRV 01 DRV 02 DRV 03 DRV 04 DRV 05 Description Cmd. time Current Speed Power Default 0 50 100 Min. 60000 60000 Units 0. 01 Hz 0. 1 sec 0. 1 sec 0. 1 A RPM 0. 1 kW
8
MODBUS REGISTERS
3. 3
Function Group
The registers in the Function Group allow access to all of the parameters in the Function Group that are available through the keypad.
Address 16641 Keypad FUN 01 Description Freq. set Default Key Minimum 0 Key 1 Terminal 2 Remote 0 Key 1 Terminal-1 2 Terminal-2 3 Remote 0 None 1 FWD disable 2 REV disable 4000 4000 50 0 0 Linear 1 Squared 2 User 3 Auto Boost 0 0 0 Linear 1 S-Curve 2 U-Curve 0 Linear 1 S-Curve 2 U-Curve 40 70 0 Decel 1 DCBR 2 Free Run 0 0 0 15 0 V1 1I 2 V1 + I 3 V2 1 100 3000 50 Freq. max 500 100 Maximum Units -
16642
FUN 02
Run/stop set
Key
-
16643 16644 16645 16646 16647
FUN 03 FUN 04 FUN 05 FUN 06 FUN 07
Run Prohibit Freq. start Hold time
None 6000 6000 50 0
0. 01 Hz 0. 01 Hz 0. 01 Hz 0. 1 sec
16648
FUN 08
V/F pattern
Linear
-
16649 16650 16651
FUN 09 FUN 10 FUN 11
Fwd boost Rev boost Acc. pattern
2 2 Linear
1% 1% -
16652 16653 16654 16655 16656 16657 16658 16659
FUN 12 FUN 13 FUN 14 FUN 15 FUN 16 FUN 17 FUN 18 FUN 19
Dec. pattern Volt control Energy save Stop mode User-1f User-1v User-2f User-2v
Linear 100 100 Decel 1000 15 3000 50
1% 1% 0. 01 Hz 1% 0. 01 Hz 1%
16660
FUN 20
V-I mode
V1
-
16661
FUN 21
Filter gain
75
1%
9
MODBUS REGISTERS
Address 16662 16663 16664 16665 16666 16667 16668 16669 16670 16671 16672 16673 16674 16675 16676 16677 16678 16679 16680
Keypad FUN 22 FUN 23 FUN 24 FUN 25 FUN 26 FUN 27 FUN 28 FUN 29 FUN 30 FUN 31 FUN 32 FUN 33 FUN 34 FUN 35 FUN 36 FUN 37 FUN 38 FUN 39 FUN 40
Description Analog gain Analog bias Analog dir Freq. jump Freq-jump 1f Freq-jump 2f Freq-jump 3f Freq. band DC-br freq On-del time DC-br time DC-br value Slip compen. No-load cur.
Default 1000 1000 Direct No 6000 0 No 1000 2000 3000 500 50 20 5 1 No 0 1030 1
Minimum 500 0 0 Direct 1 Invert 0 No 1 Yes 0 0 0 No 1 Yes 0 0 0 0 0 5 1 1 0 No 1 Yes 0 1 1 0 RSi040H-2 1 RSi050H-2 2 RSi060H-2 3 RSi075H-2 4 RSi040H-4 5 RSi050H-4 6 RSi060H-4 7 RSi075H-4 0 0
Maximum 2500 2000
Units 0. 1 % 0. 1 % -
Freq. [. . . ] · Card not installed properly · Drive not operating normally · Verify that the card is installed properly · Verify that the drive has power Corrective Measures
State Blinking
Off
4. 2
RXD and TXD LEDs
Indicates · The card is functioning normally and receiving and sending messages · Incorrect Modbus connection to the card · Verify that the A(-) signal is connected to terminal N and the B(+) signal is connected to terminal P · Verify that the master (PLC or PC) is polling the drive · Verify that the baud rate (I/O 51) is set to match the baud rate of the master · The drive communicates using 8 data bits, 1 stop bit and no parity bits. Verify that the master is set to the same Corrective Measures
State Blinking
· Master is not polling Off · Incorrect baud rate setting · Incorrect byte format
14
TROUBLESHOOTING
4. 3
ERR LED
State Off Blinking slowly Indicates · The card is functioning normally · The card is receiving invalid requests · Connection failure with main inverter PCB · Network connection time out · Verify that the master is specifying valid register addresses and valid data · Verify that the option selection (I/O 48) is set to Modbus RTU · Ensure that the master polls the drive more frequently than the time out setting (I/O 52) Corrective Measures
Blinking simultaneously with the CPU LED Blinking alternately with the CPU LED
15
BENSHAW SERVICES
5. Benshaw Services
Benshaw offers its customers the following services: · Start-up services · On-site training services · Technical support · Detailed documentation · Replacement parts Benshaw technical field support personnel are available to assist customers with the initial start-up of the RSi H-Series Inverter. Information about start-up services and fees are available by contacting Benshaw. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BENSHAW RSI (H-SERIES) MODBUS CARD
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BENSHAW RSI (H-SERIES) MODBUS CARD will begin.