Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BIAMP ADVANTAGE SCM 7500 S. We hope that this BIAMP ADVANTAGE SCM 7500 S user guide will be useful to you.
Lastmanuals help download the user guide BIAMP ADVANTAGE SCM 7500 S.
Manual abstract: user guide BIAMP ADVANTAGE SCM 7500 S
Detailed instructions for use are in the User's Guide.
[. . . ] To create an iD of hex B7, turn the LSB switch to 7 and turn the mSB switch to B. Device iD switches should be set using a 0. 1 inch (2. 5mm) to 0. 12 inch (3. 0mm) flat blade screwdriver. More information on setting IDs and the hexadecimal numbering scheme used in Vocia can be found in the Vocia Help File. Please note: Changes made to the Device iD while connected to the network require a power cycle in order to take effect.
Network Connection The TTS-1 has four RJ45 Ethernet connectors located on the rear panel (Control, Vocia Network, and Spare). [. . . ] Each connector has two green LEDs, which display Ethernet Link (left LED) and Activity (right LED). LAN-1 Connector (Control) This port connects the TTS-1 to a control network. This should be separate to the LAN that is being used by the CobraNet port either physically or through the use of managed switches and VLANs. The TTS-1 can be configured in the Vocia software interface via this port, and as such it should be connected to the same network as the configuration PC during set up. It also supports inter-world paging and communications. LAN-2 Connector (CobraNet) This port is used to communicate with local Vocia devices and as such should be connected to the same network as the local Vocia system. The data from the CobraNet network should be placed on its own LAN, either physically or through the use of managed switches and VLANs. LAN-3 and LAN-4 Connectors (Spares) These ports are inactive at this time.
6
TTS-1 rear panel
AC Power Entrance (IEC) The iEC power entrance provides for connection of the appropriate power cord (included with unit). An internal universal switching power supply accepts 100240VAC @ 50/60Hz, with a maximum power consumption of 350 watts. · First, remove the screw from the TTS-1 chassis (with a Phillips P2 screw driver) · Attach the appropriate rack ear and re-affix the Phillips screw to the chassis and 4 additional Philips screws supplied with the rack ears. please install the unit away from heat sources, such as vents and radiators, and in rooms with adequate ventilation. Ensure that air can circulate freely behind, beside, and above the unit. Do not exceed the maximum ambient operating temperature of 113 degrees F (45°C). Be aware of conditions in an enclosed rack that may cause the temperature to exceed ambient room conditions.
585. 0270. 90A 8
TTS-1 SpecificaTiOnS
Text-to-Speech Server 1 SPECIFICATIONS
Connection: RJ45 with shielded Ethernet/PoE cable (Cat5, Cat5e, Cat6 , or Cat7) Weight: 12 lb (5. 4 kg)
Power Consumption (100240VaC 50/60Hz): Dimensions: Height: Width: Depth:
< 350 watts
ambient Operating temperature Range: Compliance:
32-113 degrees F (0-45 degrees C) EU Directive 2002/95/EC, RoHS directive CE marked
0. 75 inches (44. 5 mm) 19 inches (483 mm) 17. 5 inches (444 mm)
Text-to-Speech Server 1 Block Diagram
RS-232 USB VGA
LED ID Switches Storage Drive Host Processor
Control
CobraNet®
9
TTS-1 warranTy
BiAmp SYSTEmS iS pLEASED TO EXTEND THE FOLLOWiNG 5-YEAR LimiTED WARRANTY TO THE ORiGiNAL pURCHASER OF THE pROFESSiONAL SOUND EQUipmENT DESCRiBED iN THiS mANUAL 1. BiAmp Systems warrants to the original purchaser of new products that the product will be free from defects in material and workmanship for a period of 5 YEARS from the date of purchase from an authorized BiAmp Systems dealer, subject to the terms and conditions set forth below. 2 if you notify BiAmp during the warranty period that a BiAmp Systems product fails to comply with the warranty, BiAmp Systems will repair or replace, at BIAMP Systems' option, the nonconforming product. As a condition to receiving the benefits of this warranty, you must provide BiAmp Systems with documentation that establishes that you were the original purchaser of the products. Such evidence may consist of your sales receipt from an authorized BiAmp Systems dealer. [. . . ] Such evidence may consist of your sales receipt from an authorized BiAmp Systems dealer. Transportation and insurance charges to and from the BiAmp Systems factory for warranty service shall be your responsibility. This warranty will be VOiD if the serial number has been removed or defaced; or if the product has been altered, subjected to damage, abuse or rental usage, repaired by any person not authorized by BiAmp Systems to make repairs; or installed in any manner that does not comply with BiAmp Systems' recommendations. Electro-mechanical fans, electrolytic capacitors, gooseneck microphones, cords connecting handheld microphones, hard-drives, displays, and normal wear and tear of items such as paint, knobs, handles, keypads and covers are not covered under this warranty. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BIAMP ADVANTAGE SCM 7500 S
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BIAMP ADVANTAGE SCM 7500 S will begin.