If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BIAMP AP4622 POWER AMP. We hope that this BIAMP AP4622 POWER AMP user guide will be useful to you.
Lastmanuals help download the user guide BIAMP AP4622 POWER AMP.
Manual abstract: user guide BIAMP AP4622 POWER AMP
Detailed instructions for use are in the User's Guide.
[. . . ] The information supplied by this manual relates to physical connections and assignment. For more details on software setup, please consult the Vocia Help File.
Input 6
Power/ Network
1 Audio Channel
2
3
4
5
6
1 Control Inputs
2
3
4
1 Control Outputs
2
3
4
1. Power Indicator LED On the left of the front panel, the VI-6 has a single LED that indicates power and connectivity status: 1. Not illuminated: The device is not powered. 2. Flashing green: The unit is receiving power but not data, or the unit has not been configured correctly. [. . . ] Signal LEDs Six LEDs located in the center of the front panel act as audio signal identifiers for the four input channels and are useful for setting optimum signal levels. please see the table below for the signal mapping to each of the LEDs. Detailed metering of current output levels can be obtained in real time via the Vocia software interface.
-3 -18 Red
Clip
Yellow
Nominal -48
Green
Threshold
Red Signal above clip threshold > -3dBFS
Yellow Signal above nominal but below clip threshold > -18dBFS < -3dBFS
Green Signal above minimum but below nominal threshold > -48dBFS < -18dBFS
Dark Signal below minimum threshold < -48dBFS
3 . Control LEDs The control LEDs signal the current state of the control I/Os. The first four are input status indicators, and the second four are output status indicators. They have three states: Yellow Relays are energized Green > input threshold 4 Dark Not active
VI-6 rear Panel cOntrOls
Control Inputs
BIAMP SYSTEMS
Designed in Australia Assembled in USA N24138 YEL:in use/conductor GRN:link/act
RCA Inputs
+Input 5 Paging Ports
1
2
+-
Input 1 LR
Input 3 LR
Model VI-6
Control Inputs
Device ID GND
CobraNet® PoE IEEE 802. 3af Class 0
Control Outputs LR LR Input 4
MSB
LSB
C NC NO C NC NO 1 2
C NC NO 3
C NC NO 4
3
4 10V
(100mA)
+-
Input 2
+-
+-
Input 6
1
2
3
4
Device ID Network Connection Control Outputs
plug-in Barrier Strip Analog Inputs
Not Active
Network Connection The VI-6 has one RJ45 connector that should wired to standard copper Ethernet cabling to interface the VI-6 to a Vocia system via a poEcompliant network switch. The RJ45 connector has two LEDs that indicate Ethernet link and network activity (see table below). Left LED None None Flashing yellow Flashing yellow Flashing yellow Right LED None Green Green Flashing green None Description No power or data connectivity. please check the poE network connection. Link established and CobraNet activity detected; the unit is acting as a CobraNet performer. (10V): 10V reference voltage (when used as a switch input, a switch must be connected between the input and logic common terminal) Audio Inputs Two sets of plug-in barrier strip and RCA connectors provide analog audio signal input. Inputs 1 through 4 are designed for line-level input. The RCA and plug-in barrier strip connectors are resistively summed internally so that a stereo source can be conveniently converted to mono audio. Inputs 5 and 6 are designed for microphone or line-level inputs and include phantom power. All plug-in barrier strip connectors should be wired from left to right as follows: 1. ( ) Ground Ground Screw This screw provides a connection point to ground the chassis of the VI-6. The power supply to the VI-6 is sourced from poE, which may have no connection to ground. The chassis of the VI-6 should be connected to a safety ground (main power supply ground) using the Ground Screw
7
VI-6 InstallatIOn
Installation The VI-6 requires one 1. 75 inch (44. 45mm) high and 19 inch wide (483mm) rack space with 10 inch (254mm) depth. Mounting the unit using four screws with washers will prevent marring of the front panel. Please install the unit away from heat sources, such as vents and radiators, and in rooms with adequate ventilation. [. . . ] Ensure that air can circulate freely behind, beside, and above the unit. Do not exceed the maximum ambient operating temperature of 113 degrees F (45°C). Be aware of conditions in an enclosed rack that may cause the temperature to exceed ambient room conditions.
585. 0247. 90A 8
VI-6 sPecIfIcatIOns
Vocia Input 6 SPECIFICATIONS
Frequency Response Line Inputs: Mic/Line Inputs: + or 1dB, 20Hz-20kHz + or 1dB 35Hz to 20kHz Control Inputs Type: Max Input Threshold: Max Input Voltage: Min Input Threshold: Input Impedance: Control Outputs Type: Max Operating Voltage: Max Switching Capacity: Min Operating Load: Connection: Power: Dimensions: Height: Width: Depth: Weight: Ambient Operating Temperature Range: Compliance: Mic Inputs Phantom Power: A/D Converters: 18V behind 3. 3k/leg 24-bit (48kHz sampling) Digital, variable threshold 10V 12V 150mV 100k Form C Voltage free change over contact 125VAC, 60VDC 37VA 10µA @ 10mV DC RJ45 with shielded Ethernet/PoE cable (CAT5, CAT5e, CAT6, or CAT7) 802. 3af (PoE) Class 3 0. 75 inches (44. 5mm) 19 inches (483mm) 10 inches (254mm) 6. 4 lbs. BIAmp Systems disclaims all other warranties, expressed or implied, including, but not limited to, implied warranties of merchantability and fitness for a particular purpose. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BIAMP AP4622 POWER AMP
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.