If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BIAMP AUDIA/NEXIA CONTROL LABEL TEMPLATE. We hope that this BIAMP AUDIA/NEXIA CONTROL LABEL TEMPLATE user guide will be useful to you.
Lastmanuals help download the user guide BIAMP AUDIA/NEXIA CONTROL LABEL TEMPLATE.
You may also download the following manuals related to this product:
BIAMP AUDIA/NEXIA CONTROL LABEL TEMPLATE annexe 1 (28 ko)
Manual abstract: user guide BIAMP AUDIA/NEXIA CONTROL LABEL TEMPLATE
Detailed instructions for use are in the User's Guide.
[. . . ] A line feed needs to be sent after each command string sent. The ATP string is structured in the following order: Command DeviceNumber Attribute InstanceID Index1 Index2 Value <LF> ATP strings require a space between each parameter; the last character in the string needs to be a line feed <LF>. A space is not required before a line feed, but is acceptable and is used in examples shown in this manual (for legibility only). A space normally proceeds the carriage return/line feed <CR><LF> in a response to a GET command (see Command and Responses). [. . . ] Example: Set Device 1 Room Combiner Wall State at Instance 4 Wall 2 to up (close/separate). Command Dev # Attribute Inst ID Index 1 Index 2 Value SET 1 RMCMBWALL 4 2 None 1 Result: SET 1 RMCMBWALL 4 2 1 <LF>
Line Feed <LF>
Auto-Mixer Combiner Group State
Attribute MCMBGROUP
Commands SET, GET
Index 1
Value Range 0 ~ 32
Note: Index1 is the input being addressed. Value is the group; this is represented by a letter in Audia software, but addressed as a number in ATP commands. (Example: ungroup=0, A=1, B=2, C=3. . . . ) Note: The Auto-Mixer Combiner was previously the Mix-Minus Combiner. The above command will continue to work with a Mix-Minus Combiner block in a previously created Audia file with a Mix-Minus Combiner.
Equalizer Blocks
Graphic EQ EQ Band Level Bypass All Bands Attribute GEQLVLBND GEQBYPALL Commands SET, SETL, GET, GETL, INC, DEC SET, GET Index 1 Value Range -30 ~ 15 *
None 0 = active 1 = bypassed * Can contain a decimal number.
Note: Index1 represents the filter to be controlled. Graphic EQ filters are numbered from left to right, and the selected band is displayed in the upper left hand corner of the Graphic EQ dialog screen in Audia software. Use this number as Index1 for Graphic EQ strings. Example: Set Device 2 Graphic EQ Bypass All Bands at Instance 9 to bypass. Command Dev # Attribute Inst ID Index 1 Index 2 SET 2 GEQBYPALL 9 None None Result: SET 2 GEQBYPALL 9 1 <LF> Parametric EQ EQ Bandwidth Bypass EQ Band Center Freq. EQ Band Level Bypass All Bands Attribute PEQBWBND PEQBYPBND PEQFCBND PEQLVLBND PEQBYPALL Commands SET, SETL, GET, GETL SET, GET SET, SETL, GET, GETL, INC, DEC SET, SETL, GET, GETL, INC, DEC SET, GET Index 1 1 1 1 Value Range 0. 010 ~ 4. 000 * 0 = active 1 = bypassed 20 ~ 20000 -30 ~ 15 *
Value 1
Line Feed <LF>
None 0 =active 1 = bypassed * Can contain a decimal number.
Note: Index1 represents the filter to be controlled. Parametric EQ filters are initially numbered from left to right, and the selected band is displayed in the upper left hand corner of the Parametric EQ dialog screen in Audia software. Command SET Dev # 1 Attribute DLYCM Inst ID 24 Index 1 None Index 2 None Value 40 Line Feed <LF>
Result: SET 1 DLYCM 24 40 <LF>
Control Blocks
Level Faders Fader Level Fader Mute Attribute FDRLVL FDRMUTE Commands SET, SETL, GET, GETL, INC, DEC SET, GET Index 1 1 Value Range -100 ~ 12 *
0 = unmuted 1 = muted * Can contain a decimal number. Index 1 Value Range 0 = unmuted 1 = muted
Mute Button Mute
Attribute MBMUTE
Commands SET, GET
Logic State Logic State
Attribute LGSTATE
Commands SET, GET
Index 1
Value Range 0 = off 1 = on
Presets Preset
Attribute PRESET
Commands RECALL
Index Value Range None 1001 ~ maximum number of presets
Note: Instead of SET, SETL, GET, GETL, INC, or DEC; the Preset attribute uses RECALL as the command. Regardless of preset name, the first preset defined is 1001, the second is 1002, and so forth. However, the numbers of any deleted Presets will not be available. Since Presets apply to entire systems, the Device Number will always be 0 for Preset strings. Example: Recall Device 0 Preset number 1001. Command RECALL Dev # 0 Attribute PRESET Inst ID None Index 1 None Index 2 None Value 1001 Line Feed <LF>
Result: RECALL 0 PRESET 1001 <LF> (use RECALL instead of SET/GET commands)
Index
Meter Blocks
Meters Attribute Signal Present Meter SPMTRSTATE Peak Meter RMS Meter Logic Meter PKMTRLVL RMSMTRLVL LGCMTRSTATE Commands GET GET, GETL GET, GETL GET Value Range 0 = no signal present 1 = signal present 1 -100 ~ 36 * 1 -100 ~ 36 * 1 0 = no signal present 1 = signal present * Can contain a decimal number. Index 1
Note: Meters only use GET and GETL commands, which do not include a Value. Instead, Audia will respond to these GET/GETL commands with the requested value (current level). Example: Get Device 1 RMS Meter Level at Instance 48 Meter 1. Command GET Dev # 1 Attribute RMSMTRLVL Inst ID 48 Index 1 1 Index 2 None Value None Line Feed <LF>
Result: GET 1 RMSMTRLVL 48 1 <LF> (use GET/GETL commands only)
Generator Blocks
No Attributes are specified at this time
Index
Instance ID
Audia uses an Instance ID number to specify the exact DSP block to be controlled. [. . . ] Simply type: "CLEAR 0 DEVCONFIG <LF>" and the device will be reset. Reboot Device When needed, the Audia can be restarted without suspending audio. Simply type: "REBOOT 0 DEVICE". This will restart a single Audia device without suspending audio.
Index
CobraNet IP Address
These attributes and resulting commands affect the Audia CobraNet IP Configuration. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BIAMP AUDIA/NEXIA CONTROL LABEL TEMPLATE
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BIAMP AUDIA/NEXIA CONTROL LABEL TEMPLATE will begin.