If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BIAMP AUDIAEXPI-D-EXPO-D. We hope that this BIAMP AUDIAEXPI-D-EXPO-D user guide will be useful to you.
Lastmanuals help download the user guide BIAMP AUDIAEXPI-D-EXPO-D.
Manual abstract: user guide BIAMP AUDIAEXPI-D-EXPO-D
Detailed instructions for use are in the User's Guide.
[. . . ] AudiaEXPI-D
&
AudiaEXPO-D
Digital Input & Output Expanders
Operation Manual
Biamp Systems, 10074 S. W. Arctic Drive, Beaverton, Oregon 97005 U. S. A.
(503) 641-7287
www. biamp. com
blank
16Mar07
AudiaEXPI-D & AudiaEXPO-D
TABLE OF CONTENTS AudiaEXPI-D - front & rear panels AudiaEXPO-D - front & rear panels Encoder/Display Menus Application Specifications Block Diagrams Warranty CE Declaration Safety Information pg. 12~14 AudiaEXPI-D is a digital input expander for AUDIA®, the benchmark in digital audio systems for demanding professional sound installations. AudiaEXPI-D accepts eight channels of digital audio input and provides eight channels of digital audio output via CobraNet®. [. . . ] Additional Ethernet switches, or even fiber-optics, can be used to further extend distances between units on a system network. The primary and secondary CobraNet ports are redundant. CobraNet supports 64 channels of digital audio (32-in & 32-out) over Fast Ethernet, using CAT-5 cable. CobraNet transmits (32) channels of digital audio on (4) 'bundles' of (8) channels each. The same is true for receiving digital audio over CobraNet. Bundle numbers are used to determine where digital audio is transmitted and received. Typically, 'unicast' bundle numbers (256~61, 439) are used to exchange digital audio between two specific devices. With 'unicast' bundles, each CobraNet device can transmit to no more than (4) other devices within a network. With 'multicast' bundle numbers (1~255), digital audio can be exchanged with multiple devices. Due to network delay, CobraNet has a limitation of seven (7) 'hops' (one-way transmissions) within a network. In order to integrate AudiaEXPO-D into a AUDIA system, an EXPO-D (or CobraNet) output block must first be placed into the design layout. AUDIA units intended to transmit digital audio to the AudiaEXPO-D must have their CobraNet jacks connected to the same network. Both the AudiaEXPO-D unit (hardware) and the EXPO-D output block (software) must be assigned matching bundle numbers, before digital audio can be successfully exchanged. AudiaEXPO-D bundle number assignment can be changed in real-time to allow access to digital audio from different EXPO-D output blocks within the system. CobraNet Latency settings must be identical in all devices, system-wide. Also, unicast and multicast bundle numbers can be used to access digital audio from individual or multiple EXPO-D output blocks. Similar considerations may apply when using AudiaEXPO-D with other CobraNet compliant systems or devices. AudiaEXPI-D and AudiaEXPO-D can exchange digital audio directly (outside of a system network) using either a simple 'cross-over' CAT5 cable or an Ethernet switch.
3
ENCODER/DISPLAY MENUS
At power-up, the display will flash three product ID screens, ending on a customizable Title screen. Pressing the encoder while on the Title screen will reveal the Main Menu. Rotate encoder to cycle through available selections. EXPI-D detects emphasis of the digital audio input sources. EXPO-D settings must be compatible with source signals. [. . . ] 4, 922, 536
CobraNet® connections only
12 watts class 2 wiring
123
456
78
-D
word clock out
TOSLINK
AES3
TOSLINK
AES3
SPDIF
AES3
SPDIF
AES3
CobraNet
digital audio to broadcast & media feeds
EtherNet Switch
AudiaFLEX 8-out CM
100-240V~ 50/60Hz
Serial Control Port
CAUTION
RISK OF ELECTRICAL SHOCK. DO NOT OPEN.
Installation Instructions: Telephone Interface TI-2
This device must be installed by qualified, trained personnel. Connections to the telephone network must be made with #26 AWG solid copper wire for continued safety.
®
BIAMP SYSTEMS MODEL TI-2 US:6RMBR00BAUDIATI2 IC:3184A-AUDIATI-2
BIAMP SYSTEMS
designed and assembled in the USA www. biamp. com
In 23
In 21
In 19
In 17
In 15
In 13
In 11
In 9
In 7
In 5
In 3
In 1
150 Watts
CobraNet connections only
primary secondary
in use / conductor link / activity LEDs
®
Out 1 In 24
Out 3 In 22
Out 5 In 20
Out 7 In 18
Out 9 In 16
Out 11 In 14
Out 13 In 12
Out 15 In 10
Out 17 In 8
Out 19 In 6
Out 21 In 4
Out 23 In 2
U. S. 4, 922, 536
C
UL
R
US
24VDC 1. 5A Out 2 Out 4 Out 6 Out 8 Out 10 Out 12 Out 14 Out 16 Out 18 Out 20 Out 22 Out 24
LISTED
52SJ
link
Ethernet
term hi lo Remote Control Bus
class 2 wiring YELLOW connectors = AMP OUTPUTS
BLACK connectors = OUTPUTS
ORANGE connectors = AEC INPUTS
GREEN connectors = INPUTS
remote control options: Volume 8, Select 8, Volume/Select 8, Logic Box (volumes, presets, muting, scenes, routing, etc. )
remote control
CAUTION
RISK OF ELECTRICAL SHOCK. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BIAMP AUDIAEXPI-D-EXPO-D
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BIAMP AUDIAEXPI-D-EXPO-D will begin.