User manual BIAMP AUDIAFUSION

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BIAMP AUDIAFUSION. We hope that this BIAMP AUDIAFUSION user guide will be useful to you.

Lastmanuals help download the user guide BIAMP AUDIAFUSION.


Mode d'emploi BIAMP AUDIAFUSION
Download

You may also download the following manuals related to this product:

   BIAMP AUDIAFUSION SHEET (476 ko)

Manual abstract: user guide BIAMP AUDIAFUSION

Detailed instructions for use are in the User's Guide.

[. . . ] . FEATURES · Modular based design · Amplification modules have software configurable power levels/load options ­ 8 amplification modules per frame with 100W to 600 Watts per module (maximum of 2400W per chassis) ­ 70 V or 100 V with direct drive capability, or low-impedance (4 or 8) operation ­ Maximum of 2400 watts of power in 3 rack unit device · TCP/IP Network controllable · LED Indication: ­ Signal present ­ Peak present ­ Clip present ­ Heat sink temperature fault ­ Amplifier failure ­ Fan stuck-rotor · Internal amplifier module failover mode · Entire device failover mode · Software Monitoring Features: ­ Peak present ­ Heatsink temperature value, warning and fault ­ Short circuit on output ­ Amplifier failure ­ Impedance min/max threshold warning ­ Excessive clipping ­ Fan stuck-rotor · Seamless integration with CobraNet-enabled Audia systems · CobraNet Interface (16 channels in/16 channels out) · CobraNet latency 5-1/3, 2-2/3 or 1-1/3 ms, software configurable · Dual Ethernet ports for redundancy · Selectable 115/230 volt operation · Control via RED-1, daVinci or third party control systems · CE marked, UL listed and RoHS compliant · Covered by BIAMP Systems' five-year warranty 3 AudiaFUSION FRONT PANEl Setup and Use The Audia software provides the interface for configuring and programming AudiaFUSION. The information supplied by this manual relates to hardware installation, physical connections, and device and channel failover concerns. For more details on software setup, please consult the Audia software Help File. Front Panel alarm activity signal 1 signal 2 status ais power System Indicators The LED indicators on the front panel provide information about the function and operational status of the AudiaFUSION chassis and any installed AM-600 amplifier modules. [. . . ] DO NOT OPEN. FUSE FUSE Primary 220-240V: T 12 H, 250V 110-120V: T 20 H, 250V Ethernet 110-120/220-240V~ 115V 50/60Hz 2400WATT CobraNet® Connections Only YEL: In use/Conductor GRN: Link/Activity NM-1 OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT AM-600 OUTPUT Class 2 Wiring Class 2 Wiring BIAMP SYSTEMS Logic I/O Class 2 Wiring Class 2 Wiring Class 2 Wiring Class 2 Wiring Class 2 Wiring 52SJ Serial Control Port After initial programming and configuration, AudiaFUSION may be controlled by third-party control systems such as AMX® or Crestron® using the Serial Control Port. External devices may also be controlled or signaled via the Serial Control Port by utilizing Command String blocks within the Audia system design. The port is a DB9 female with pin 2 [RXD], pin 3 [TXD], and pin 5 [GND] connected. The default settings are 38400, 8, N, 1, None. A 10/100Base-T Ethernet switch (not repeater hub) is required when networking multiple units. CobraNet utilizes standard CAT5, CAT5e, CAT6, or CAT7 cabling, which has a specified maximum length of 100 meters. Additional Ethernet switches and/or fiber-optic cable can be used to further extend distances between units on a network. 6 Secondary LEDs Class 2 Wiring AudiaFUSION REAR PANEl Please note that CobraNet limits network extensions to seven hops (one-way transmissions) within a network. The primary and secondary CobraNet ports are redundant. Each connector provides two LEDs that indicate Ethernet link and network activity (see table below). CobraNet interface status LEDs Left LED None Green Green Flashing green Flashing amber Right LED None None Flashing amber Flashing amber Flashing amber Description No data connectivity. Link established and CobraNet activity detected; the unit is acting as a CobraNet performer. Link established and CobraNet activity detected; the unit is operating as a CobraNet conductor. Check cabling and configuration for errors. AM-600 AM-600 is the Amplifier Module card. An AudiaFUSION chassis can be populated with up to eight AM-600 cards. Output Use the yellow plug-in barrier strip connectors to connect loudspeaker level outputs. If stranded speaker wire is used, be sure to incorporate all strands into the connector, as stray strands can short to the adjacent terminal or chassis. Do not leave excessive bare wire outside the terminals, as this can lead to shorts. Please note: AudiaFUSION is a powerful amplifier and can damage loudspeakers. Please treat the outputs as you would AC mains power outlets. Always check the loudspeaker's continuous and peak power capabilities and match the amplifier settings accordingly. 7 AudiaFUSION REAR PANEl Amplifier-to-Amplifier Failover AudiaFUSION supports one-to-one automatic device failover in case of fault. Failover is triggered by one of the following conditions: · Chassis alarm · Channel alarm · Loss of power · Loss of CobraNet link · Loss of Logic I/O Only alarms (e. g. , heat sink alarm and channel failure alarm) trigger the failover mechanism. Warnings indicate abnormal system conditions that do not immediately impair audio and do not trigger the failover mechanism. [. . . ] Statements, representations or warranties made by any dealer do not constitute warranties by BIAMP Systems. BIAMP Systems shall not be responsible or liable for any statement, representation or warranty made by any dealer or other person. No action for breach of this warranty may be commenced more than one year after the expiration of this warranty. Biamp systems shall not be liable for special, indirect, incidental, or consequential damages, including lost profits or loss of use arising out of the purchase, sale, or use of the products, even if BIAMP Systems was advised of the possibility of such damages. 13 DoC DSPA201003 EC Declaration of Conformity Biamp Systems Corporation, as manufacturer having sole responsibility, hereby declares that the following described product complies with the applicable provisions of the DIRECTIVES below except as noted herein. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BIAMP AUDIAFUSION

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BIAMP AUDIAFUSION will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag