If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BIAMP DJ 4000 AND 4001. We hope that this BIAMP DJ 4000 AND 4001 user guide will be useful to you.
Lastmanuals help download the user guide BIAMP DJ 4000 AND 4001.
Manual abstract: user guide BIAMP DJ 4000 AND 4001
Detailed instructions for use are in the User's Guide.
[. . . ] 15) The MAINS plug or appliance coupler is used as the disconnect device. This disconnect device must remain redily accessible after installation. 16) In order to comply with international safety requirements for operating temperature, clearance of at least 5cm or 1. 97" must be maintained between this device and other rack-mounted devices. This spacing will ensure that all exposed metal surfaces are safe to touch. [. . . ] The channel will attempt to self-reset once the over-temperature or output fault condition is resolved. On Indicator: This green LED remains lit when AC power is applied to the unit.
2
REAR PANEL
MCA 8050 rear panel
CAUTION: Risk of fire replace fuse only with same type 115V: F 10 A H 250 V 230V: T 4 A L 250 V
C
UL
R
FUSE
US
remote control
CAUTION
RISK OF ELECTRICAL SHOCK. DO NOT OPEN.
MCA 8050
signal / peak signal / peak
BIAMP SYSTEMS
Designed in Oregon, U. S. A. Assembled in India
signal / peak
signal / peak
signal / peak
signal / peak
signal / peak
level
level
level
level
level
level
level
level
HPF BRIDGE HPF
HPF BRIDGE HPF
HPF BRIDGE HPF
115
input
input
input
input
input
input
input
HPF BRIDGE HPF
O
input
8
outputs
7
6
outputs
5
Class 2 Wiring
4
outputs
3
2
outputs
1
~115/230VAC 50-60Hz 900 Watts
MCA 8150 rear panel
remote control
CAUTION
RISK OF ELECTRICAL SHOCK. DO NOT OPEN.
MCA 8150
BIAMP SYSTEMS
Designed in Oregon, U. S. A. Assembled in India
CAUTION: Risk of fire replace fuse only with same type 115V: F 15 A H 250 V 230V: T 6. 3 A L 250 V
C
UL
R
FUSE
US
LISTED
signal / peak
52SJ
signal / peak
signal / peak
signal / peak
signal / peak
signal / peak
signal / peak
level
level
level
level
level
level
level
level
HPF BRIDGE HPF
HPF BRIDGE HPF
115
input
input
input
input
input
HPF BRIDGE HPF
input
input
HPF BRIDGE HPF
O
input
8
outputs
7
6
outputs
5
Class 2 Wiring
4
outputs
3
2
outputs
1
~115/230VAC 50-60Hz 1800 Watts
3
signal / peak
8
OFF OFF OFF
7
6
OFF OFF OFF
5
4
OFF OFF OFF
3
2
OFF OFF OFF
1
signal / peak
OFF OFF OFF
OFF OFF OFF
OFF OFF OFF
OFF OFF OFF
FUSE
FUSE
LISTED
52SJ
8
7
6
5
4
3
2
1
REAR PANEL
Input: These plug-in barrier strips provide the balanced line-level inputs to the channels. For balanced connection, wire high (+), low (-), and ground ( ). For unbalanced connection, wire high (+) and ground to both ( ) & (-). NOTE: When using a pair of channels in 'bridged' mode (see Bridge below), input signal must be connected to the odd numbered channel. Level: These screw-driver adjustable controls determine the level of input signals allowed into the channels. Level provides a gain range from 'off' (min. ) to 'unity' (max. ). Output transformers for 25/70/100 Volt speaker systems are available as an option (installation instructions are included with the output transformers). Transformers (by model) are as follows: TDT50 = MCA 8050 individual channels (50 Watts) TDT100 = MCA 8050 bridged channels (100 Watts) TDT150 = MCA 8150 individual channels (150 Watts) TDT300 = MCA 8150 bridged channels (300 Watts) Remote Control: This 15-pin Sub-D (female) connector provides remote level & muting control of the input channels (see Remote Control on pg. NOTE: When using a pair of channels in 'bridged' mode (see Bridge above), apply Remote Control only to the odd numbered input channel. AC Power Entrance: The switch applies AC power to the unit. The receptacle accepts the detachable AC Power Cord. The AC Power Cord is for connection to three-prong grounded AC outlets. CAUTION: Do not remove or defeat the ground prong on the AC Power Cord, as this constitutes a shock hazard. Line Voltage Selector Switch: Set this switch to "115" for nominal line voltages of 110-120 VAC. Set this switch to "230" for nominal line voltages of 220-240 VAC. Make sure that the appropriate fuse is installed when changing voltage selections. Fuse: Replace Fuse with same type and value only. [. . . ] THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. BIAMP SYSTEMS DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. The remedies set forth herein shall be the purchaser's sole and exclusive remedies with respect to any defective product. No agent, employee, distributor or dealer of Biamp Systems is authorized to modify this warranty or to make additional warranties on behalf of Biamp Systems. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BIAMP DJ 4000 AND 4001
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.