User manual BIAMP MODEL 6702-B 6702-U

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BIAMP MODEL 6702-B 6702-U. We hope that this BIAMP MODEL 6702-B 6702-U user guide will be useful to you.

Lastmanuals help download the user guide BIAMP MODEL 6702-B 6702-U.


Mode d'emploi BIAMP MODEL 6702-B 6702-U
Download
Manual abstract: user guide BIAMP MODEL 6702-B 6702-U

Detailed instructions for use are in the User's Guide.

[. . . ] If a new alarm or fault is detected, the sounder will restart. Press and hold the switch for two seconds to operate. System Test Switch ThisswitchwillinitiateatestsequenceontheLSI-16. AllindicatorsinuseontheLSI-16willlightbrieflyandthesounderintheCI-1will soundbriefly, thusconfirmingthatessentialannunciatorsarefunctional. Pressandholdtheswitchfortwosecondstoinitiatethetest sequence. System Fault Reset Switch A System Fault denotes that the LSI-16 cannot guarantee correct operation of the Vocia system in an emergency mode. [. . . ] A system fault can only be cleared by operating the System Fault Reset switch. Note that when the LSI-16 is powered up, the System Fault will be operational until the System Fault Reset switch is pressed. Press and hold the switch for two seconds to reset a System Fault. 4 ReaR Panel There are four main interconnection paths to the rear panel: · Connectionstothefiredetectionsystem(CIE); · Connections from external devices for fault indications · Connections to the LSI-16 · Power supply connections Each of these connection paths has several circuits as detailed below. Fire Detection System (CIE) Connections Thesecircuitsareprovidedontwofive-positionplug-inbarrierstripconnectors. The Isolated Ground provides a circuit return that is not directly connected to the CI-1 and LSI-16 Ground. AlarmInputs1through4aresignalsfromthefiredetectionsystem. Thesesignals placetheVociasystemintoemergencymodeaccordingtotheconfiguration determined for the input in Vocia software. The Alarm Reset Input cancels all active alarms in the system while the Alarm Silence Input maintains all active alarms but causes emergency messages to be silenced. The CI-1 provides the necessary terminating resistors for each input. Inputs are asserted by a positive transition to 12-24V with respect to the `Isolated Ground' connection. This transition should preferably be derived from a dry contact closure to a remote 12V-24V source, or to the CI-1 24V Reference Out (see below). TheVoiceAlarmActiveoutputisprovidedtosignaltothefiredetectionsystemthat the Vocia system has been activated in emergency mode in response to an Alarm Input. A constant output denotes that an emergency message is playing. The Ethernet Fault input is pulled-up internally and does not need an external pull-up. Connections to LSI-16 Thesecircuitsareprovidedonfour(4)five-positionandone(1)three-positionplug-inbarrierstripconnectorsplusaDCbarreljack. Eachconnectorlabelisprefixedby"ToLSI-16. . . "ConnectorsarelocatedsothatwiththeCI-1mounteddirectlyaboveorbelowtheLSI-16, circuit connections may be made by directly connecting pin-for-pin to the vertically adjacent connector. Short interlinking cables are provided with the CI-1 for this purpose. Refer to the LSI-16 Operation Manual for the circuit functions of these connectors. Note that the LSI-16 PSU Fault, Protection Fault and Path Fault outputs are connected to the CI-1 purely for the purpose of providing required monitoring resistors (these outputs are not otherwise used by the CI-1). If these outputs are required for remote fault indications, the relevant connections should be removed from the Monitored Outputs connector of the LSI-16. As described in the LSI-16 Operation Manual, and external monitoring resistor will be required if these circuits are so used. Power Supply Connections Thesecircuitsareprovidedonasinglefive-positionplug-inbarrierstrip. Inputs are provided for two 24V power supply circuits to drive the LSI-16. This facilitates standards compliance by providing a means of redundant connections. [. . . ] Each power supply must be capable of 24V DC at 15Watts. The Ground 1 and Ground 2 connections are internally connected together and to system ground. The VRef connection may be used as a voltage source for pull-ups on required fault inputs. This output is current limited at 100mA. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE BIAMP MODEL 6702-B 6702-U

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BIAMP MODEL 6702-B 6702-U will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag