Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BIAMP PMX84. We hope that this BIAMP PMX84 user guide will be useful to you.
Lastmanuals help download the user guide BIAMP PMX84.
You may also download the following manuals related to this product:
BIAMP PMX84 annexe 1 (1576 ko)
Manual abstract: user guide BIAMP PMX84
Detailed instructions for use are in the User's Guide.
[. . . ] PMX84
Programmable Matrix Switcher
Operation Manual
®
Biamp Systems, 10074 S. W. Arctic Drive, Beaverton, Oregon 97005 U. S. A. (503) 641-7287 http://www. biamp. com
an affiliate of Rauland-Borg Corp.
PMX84
TABLE OF CONTENTS Front & Rear Panel Features Remote Controls Logic Inputs Logic Outputs pgs. 8 & 9 INTRODUCTION The ADVANTAGE PMX84 Programmable Matrix Switcher provides eight inputs and four outputs under microprocessor control, with complete programmability and remote control of crosspoint switching via infrared, wallmount panel, logic inputs, and/or computer. [. . . ] Left-clicking a Matrix Switch Assignment or a Logic Output will `toggle' it on or off. Right-clicking will instead open a popup menu, which allows Matrix Switch Assignments & Logic Outputs to be turned on & off individually or in groups. The Mix screen provides a graphic display of all current Matrix Switch Assignments and Logic Outputs, as well as allowing real-time control of the PMX84. The title bar at the top of the Mix screen shows Device Number, custom Device Name, & Model of the product being controlled. The PC Control Software can operate `off-line' (no product connected) by opening a `new' file for the desired product. The Device Number for `off-line' files is assigned sequentially as a negative number. NOTE: Files are available for downloading during Configuration, which are designed for specific applications (see Applications on pgs. 16~21).
10
CONFIGURATION
BUTTON DEFINITION SCREENS Button Definition screens are used to assign specific `actions' to remote control buttons (and logic inputs). Button Definition screens are accessed through the Configure PMX84 drop-down menu. There are five Button Definition screen tabs to choose from (Remote 1~4 & Logic Inputs). Button Definition screens are divided into two sections. The right section indicates which Remote Control Button is currently selected. The lower set of twenty-eight buttons represents the buttons found on a standard remote control (see Remote Controls on pg. The PMX84 also supports the 12 buttons shown above, which are accessible via Remote Interface Kit or Computer control. Left-clicking a button selects it to be defined. The left section of the screen shows the Matrix Switch & Logic Output Actions assigned to the selected button. Left-clicking a Matrix Switch or Logic Output cycles through the four actions available actions (no operation, turn off, turn on, & toggle). Right-clicking instead opens a pop-up menu, allowing Matrix Switch & Logic Output Actions to be assigned individually or in groups. A button can be assigned multiple actions, affecting any number of Matrix Switches & Logic Outputs, much like a preset. Button Definition not only allows a particular button to be defined, but also from which Remote Input (1~4) that button command is received. This allows a button to perform different actions, depending upon which location it comes from. The sixteen Logic Inputs (and the Override terminal) are also available for button definition. [. . . ] Under these circumstances, Override will still shut off all room & source signals, but no emergency signal will be applied to the outputs.
301e (Room 3)
BIAMP SYSTEMS
Portland, Oregon
aux
pad pad pad
301e (Room 1)
BIAMP SYSTEMS
Portland, Oregon
aux
pad pad pad
27 VAC 18W
an affiliate of Rauland-Borg Corp.
27 VAC 18W
in out com
an affiliate of Rauland-Borg Corp.
+ --
+10V C gnd com
+ --
com
+
--
com
+
--
com
+
-MADE IN U. S. A.
in
out
com
+ --
+10V C gnd com
+ --
com
+
--
com
+
--
com
+
--
MADE IN U. S. A.
patch
main output
remote
stack input
mic/line 3
600
/ ch. 2
mic/line 1
patch
main output
remote
stack input
mic/line 3
600
/ ch. 2
mic/line 1
301e (Room 4)
BIAMP SYSTEMS
Portland, Oregon
aux
pad pad pad
301e (Room 2)
BIAMP SYSTEMS
Portland, Oregon
aux
pad pad pad
27 VAC 18W
an affiliate of Rauland-Borg Corp.
27 VAC 18W
in out com
an affiliate of Rauland-Borg Corp.
+ --
+10V C gnd com
+ --
com
+
--
com
+
--
com
+
-MADE IN U. S. A.
in
out
com
+ --
+10V C gnd com
+ --
com
+
--
com
+
--
com
+
--
MADE IN U. S. A.
patch
main output
remote
stack input
mic/line 3
600
/ ch. 2
mic/line 1
patch
main output
remote
stack input
mic/line 3
600
/ ch. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BIAMP PMX84
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BIAMP PMX84 will begin.