Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual BOSCH GWH 345 ESR. We hope that this BOSCH GWH 345 ESR user guide will be useful to you.
Lastmanuals help download the user guide BOSCH GWH 345 ESR.
Detailed instructions for use are in the User's Guide.
[. . . ] GWH 345/450 ESR
Temperature Modulated with Electronic Ignition
Suitable for heating and recirculating potable water
GWH-345/450-ESR-N - Natural Gas GWH-345/450-ESR-L - Liquefied Petroleum (LP) Gas
Warning: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Do not store or use gasoline or other flammable vapor and liquids in the vicinity of this or any other appliance. Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. For assistance or additional information consult a qualified installer, service agency or the gas supplier. [. . . ] The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted by the Board; and 2. Product approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes. (c)MANUFACTURERS REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM REQUIRED. When the manufacturer of Product Approved side wall horizontally mounted gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for the installation of the equipment and the venting shall include: 1. Detailed instructions for the installation of the venting system or the venting system components: and 2. A complete parts list for the venting system design or venting system. (d)MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a product approved side wall horizontally vented gas fueled equipment does not provide the parts for the venting of flue gases, but identifies "special venting systems, " the following requirements shall be satisfied by the manufacturer: 1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and 2. The "special venting systems" shall be product approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions. (e) A copy of all installation instructions for all products approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.
6 720 607 909
19
Installation instructions
Recommended exhaust vent terminator position
Fig. 21
Ref.
A
Description
Directly below an opening; operable windows, doors and any nonmechanical fresh air openings Below a gutter, sanitary pipework or eaves
Minimum distance
36 in (twin pipe installation) 48 in (single pipe installation) 24 in 12 in 12 in 12 in 7 ft 24 in 36 in 48 in 60 in
B
Below a gutter, sanitary pipework or eaves, protected by metal shielding From any internal corner Above ground or snow pack Above a paved sidewalk
C D*
E F G
From an opposing wall or structure facing the termination From the relief valve of a Ip gas regulator From a terminator facing a terminator Vertically between two exhaust vent terminators on the same wall
H
Horizontally between two exhaust vent terminators on the same wall Horizontally and vertically from the combustion air inlet terminator
12 in
36 in 48 in 12 in 12 in
I** From the gravity combustion air inlet any other equipment J K From any external corner Horizontally from an opening; operable windows, doors and any nonmechanical fresh air openings From wall on exhaust applications
L
10 in
Table 10
* Subject to local codes and anticipated snow level ** Other equipment that operates with a mechanical air inlet may require greater distances, reference manufacturer's instructions
NOTICE: Exhaust and air intake must always be located on the same wall to cancel wind pressure effects.
20
6 720 607 909
Installation instructions
3. 6. 7
Exhaust vent configuration examples
Fig. 22 Horizontal side wall venting installation
Fig. 24 Vertical venting installation NOTE: If appliance uses room air, do not place any other combustion appliance in the same space, to avoid depressurizing of the building and winter freeze-up. Use room sealed operation instead.
Fig. 23 Vertical venting Chimney
installation
-
Masonry
6 720 607 909
21
Installation instructions
3. 7
Gas piping & connections
Before connecting the gas supply, check the rating plate on the right side of the heater to be sure that the heater is rated for the same gas to which it will be connected. In the United States: The installation must conform with local codes or, in the absence of local codes, the National Fuel Gas Code ANSI Z223. 1/NFPA 54. In Canada: The installation must conform to CGA B149 INSTALLATION CODES and/or local installation codes. Warning: DO NOT connect to an unregulated or high pressure propane line or to a high pressure commercial natural gas line. Warning: The heater must be isolated from the gas supply piping system during any pressure testing of that system at test pressures equal to or more than 0. 5 psig. If overpressure has occurred, such as through improper testing of the gas lines or malfunction of the supply system, the gas valve must be checked for safe operation. GAS CONNECTIONS B Install a manual gas shut off valve (installer supplied) on the gas supply line. [. . . ] The Heat Exchanger If the heat exchanger fails within five (5) years after the original installation and operation, BBT North America Corporation will furnish a replacement heat exchanger at no charge. If the heat exchanger fails during years 610 after the original installation and operation, BBT North America Corporation will cover 50% of the cost of a replacement heat exchanger. However, if the water heater is installed in other than a single family dwelling, this heat exchanger replacement warranty is limited to two (2) years from date of original installation and operation. Exceptions This warranty will not apply: · 1. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE BOSCH GWH 345 ESR
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual BOSCH GWH 345 ESR will begin.